You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

452 lines
9.1 KiB
Groff

.\" Man page generated from reStructuredText.
.
.TH "SCXMLDUMP" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
.SH NAME
scxmldump \- SeisComP Documentation
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.sp
\fBDump database objects to XML files.\fP
.SH DESCRIPTION
.sp
To get event information from the database without using SQL is an important
task for the user. \fI\%scxmldump\fP queries the database and transforms that
information into XML. The result can be converted into a bulletin with
scbulletin or imported into another database with scdb\&.
.sp
An XSD schema of the XML output can be found under
\fB$SEISCOMP_ROOT/share/xml/\fP\&.
.SS Examples
.sp
Export inventory
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fI \-o inventory.xml \-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Export configuration
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fC \-o config.xml \-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Export full event data incl. the relevant journal entries
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fPAMFJ \-E test2012abcd \-o test2012abcd.xml \e
\-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Export summary event data
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fap \-E test2012abcd \-o test2012abcd.xml \e
\-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Create bulletin
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fPAMF \-E test2012abcd
\-d mysql://sysop:sysop@localhost/seiscomp | \e
scbulletin
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Copy event
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fPAMF \-E test2012abcd \e
\-d mysql://sysop:sysop@localhost/seiscomp | \e
scdb \-i \- \-d mysql://sysop:sysop@archive\-db/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Export the entire journal:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
scxmldump \-fJ \-o journal.xml \e
\-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.SH MODULE CONFIGURATION
.nf
\fBetc/defaults/global.cfg\fP
\fBetc/defaults/scxmldump.cfg\fP
\fBetc/global.cfg\fP
\fBetc/scxmldump.cfg\fP
\fB~/.seiscomp/global.cfg\fP
\fB~/.seiscomp/scxmldump.cfg\fP
.fi
.sp
.sp
scxmldump inherits global options\&.
.SH COMMAND-LINE OPTIONS
.sp
\fBscxmldump [options]\fP
.SS Generic
.INDENT 0.0
.TP
.B \-h, \-\-help
Show help message.
.UNINDENT
.INDENT 0.0
.TP
.B \-V, \-\-version
Show version information.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-file arg
Use alternative configuration file. When this option is
used the loading of all stages is disabled. Only the
given configuration file is parsed and used. To use
another name for the configuration create a symbolic
link of the application or copy it. Example:
scautopick \-> scautopick2.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-plugins arg
Load given plugins.
.UNINDENT
.INDENT 0.0
.TP
.B \-D, \-\-daemon
Run as daemon. This means the application will fork itself
and doesn\(aqt need to be started with &.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-auto\-shutdown arg
Enable/disable self\-shutdown because a master module shutdown.
This only works when messaging is enabled and the master
module sends a shutdown message (enabled with \-\-start\-stop\-msg
for the master module).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-module arg
Set the name of the master\-module used for auto\-shutdown.
This is the application name of the module actually
started. If symlinks are used, then it is the name of
the symlinked application.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-username arg
Set the name of the master\-username of the messaging
used for auto\-shutdown. If "shutdown\-master\-module" is
given as well, this parameter is ignored.
.UNINDENT
.SS Verbosity
.INDENT 0.0
.TP
.B \-\-verbosity arg
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
4:debug.
.UNINDENT
.INDENT 0.0
.TP
.B \-v, \-\-v
Increase verbosity level (may be repeated, eg. \-vv).
.UNINDENT
.INDENT 0.0
.TP
.B \-q, \-\-quiet
Quiet mode: no logging output.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-component arg
Limit the logging to a certain component. This option can
be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-s, \-\-syslog
Use syslog logging backend. The output usually goes to
/var/lib/messages.
.UNINDENT
.INDENT 0.0
.TP
.B \-l, \-\-lockfile arg
Path to lock file.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-console arg
Send log output to stdout.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-debug
Execute in debug mode.
Equivalent to \-\-verbosity=4 \-\-console=1 .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-log\-file arg
Use alternative log file.
.UNINDENT
.SS Messaging
.INDENT 0.0
.TP
.B \-u, \-\-user arg
Overrides configuration parameter \fBconnection.username\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-H, \-\-host arg
Overrides configuration parameter \fBconnection.server\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-t, \-\-timeout arg
Overrides configuration parameter \fBconnection.timeout\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-g, \-\-primary\-group arg
Overrides configuration parameter \fBconnection.primaryGroup\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-S, \-\-subscribe\-group arg
A group to subscribe to.
This option can be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-content\-type arg
Overrides configuration parameter \fBconnection.contentType\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-start\-stop\-msg arg
Set sending of a start and a stop message.
.UNINDENT
.SS Database
.INDENT 0.0
.TP
.B \-\-db\-driver\-list
List all supported database drivers.
.UNINDENT
.INDENT 0.0
.TP
.B \-d, \-\-database arg
The database connection string, format:
\fI\%service://user:pwd@host/database\fP\&.
"service" is the name of the database driver which
can be queried with "\-\-db\-driver\-list".
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-module arg
The config module to use.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-inventory\-db arg
Load the inventory from the given database or file, format:
[\fI\%service://]location\fP .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-db arg
Load the configuration from the given database or file,
format: [\fI\%service://]location\fP .
.UNINDENT
.SS Dump
.INDENT 0.0
.TP
.B \-\-listen
Enable server mode which listens to the message server for
incoming events and dumps each received add/update.
.UNINDENT
.INDENT 0.0
.TP
.B \-I, \-\-inventory
Dump the inventory.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-without\-station\-groups
Remove all station groups from inventory.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-stations sta\-list
If inventory is exported filter the stations to export where
each item is in format net[.{sta|*}].
.UNINDENT
.INDENT 0.0
.TP
.B \-C, \-\-config
Dump the configuration database.
.UNINDENT
.INDENT 0.0
.TP
.B \-J, \-\-journal
Dump the journal. In combination with \-E only corresponding
journal entries are included.
.UNINDENT
.INDENT 0.0
.TP
.B \-R, \-\-routing
Dump the routing database.
.UNINDENT
.INDENT 0.0
.TP
.B \-Y, \-\-availability
Dump data availability information.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-with\-segments
Dump individual data segments.
.UNINDENT
.INDENT 0.0
.TP
.B \-O, \-\-origin ID
Origin public ID(s) to dump. Multiple origins may be specified
as a comma\-separated list.
.UNINDENT
.INDENT 0.0
.TP
.B \-E, \-\-event ID
Event public ID(s) to dump. Multiple events may be specified
as a comma\-separated list.
.UNINDENT
.INDENT 0.0
.TP
.B \-P, \-\-with\-picks
Dump associated picks along with origins.
.UNINDENT
.INDENT 0.0
.TP
.B \-A, \-\-with\-amplitudes
Dump associated amplitudes along with magnitudes.
.UNINDENT
.INDENT 0.0
.TP
.B \-M, \-\-with\-magnitudes
Dump station magnitudes.
.UNINDENT
.INDENT 0.0
.TP
.B \-F, \-\-with\-focal\-mechanism
Dump focal mechanisms of events.
.UNINDENT
.INDENT 0.0
.TP
.B \-a, \-\-ignore\-arrivals
Do not dump arrivals part of origins.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-ignore\-magnitudes
Do not export (network) magnitudes of origins. This
option is most useful in combination with \-O to only
export the location information.
.UNINDENT
.INDENT 0.0
.TP
.B \-p, \-\-preferred\-only
When exporting events only the preferred origin, the preferred
magnitude and the preferred focal mechanism will be dumped.
.UNINDENT
.INDENT 0.0
.TP
.B \-m, \-\-all\-magnitudes
If only the preferred origin is exported, all magnitudes for
this origin will be dumped.
.UNINDENT
.SS Output
.INDENT 0.0
.TP
.B \-f, \-\-formatted
Use formatted XML output. Otherwise all XML is printed
on one line.
.UNINDENT
.INDENT 0.0
.TP
.B \-o, \-\-output
The output file. Default is stdout.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-prepend\-datasize
Prepend a line with the length of the XML data.
.UNINDENT
.SH AUTHOR
gempa GmbH, GFZ Potsdam
.SH COPYRIGHT
gempa GmbH, GFZ Potsdam
.\" Generated by docutils manpage writer.
.