.\" Man page generated from reStructuredText. . .TH "SCXMLDUMP" "1" "Jan 10, 2023" "5.3.0" "SeisComP" .SH NAME scxmldump \- SeisComP Documentation . .nr rst2man-indent-level 0 . .de1 rstReportMargin \\$1 \\n[an-margin] level \\n[rst2man-indent-level] level margin: \\n[rst2man-indent\\n[rst2man-indent-level]] - \\n[rst2man-indent0] \\n[rst2man-indent1] \\n[rst2man-indent2] .. .de1 INDENT .\" .rstReportMargin pre: . RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .\" .rstReportMargin post: .. .de UNINDENT . RE .\" indent \\n[an-margin] .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]] .nr rst2man-indent-level -1 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]] .in \\n[rst2man-indent\\n[rst2man-indent-level]]u .. .sp \fBDump database objects to XML files.\fP .SH DESCRIPTION .sp To get event information from the database without using SQL is an important task for the user. \fI\%scxmldump\fP queries the database and transforms that information into XML. The result can be converted into a bulletin with scbulletin or imported into another database with scdb\&. .sp An XSD schema of the XML output can be found under \fB$SEISCOMP_ROOT/share/xml/\fP\&. .SS Examples .sp Export inventory .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fI \-o inventory.xml \-d mysql://sysop:sysop@localhost/seiscomp .ft P .fi .UNINDENT .UNINDENT .sp Export configuration .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fC \-o config.xml \-d mysql://sysop:sysop@localhost/seiscomp .ft P .fi .UNINDENT .UNINDENT .sp Export full event data incl. the relevant journal entries .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fPAMFJ \-E test2012abcd \-o test2012abcd.xml \e \-d mysql://sysop:sysop@localhost/seiscomp .ft P .fi .UNINDENT .UNINDENT .sp Export summary event data .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fap \-E test2012abcd \-o test2012abcd.xml \e \-d mysql://sysop:sysop@localhost/seiscomp .ft P .fi .UNINDENT .UNINDENT .sp Create bulletin .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fPAMF \-E test2012abcd \-d mysql://sysop:sysop@localhost/seiscomp | \e scbulletin .ft P .fi .UNINDENT .UNINDENT .sp Copy event .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fPAMF \-E test2012abcd \e \-d mysql://sysop:sysop@localhost/seiscomp | \e scdb \-i \- \-d mysql://sysop:sysop@archive\-db/seiscomp .ft P .fi .UNINDENT .UNINDENT .sp Export the entire journal: .INDENT 0.0 .INDENT 3.5 .sp .nf .ft C scxmldump \-fJ \-o journal.xml \e \-d mysql://sysop:sysop@localhost/seiscomp .ft P .fi .UNINDENT .UNINDENT .SH MODULE CONFIGURATION .nf \fBetc/defaults/global.cfg\fP \fBetc/defaults/scxmldump.cfg\fP \fBetc/global.cfg\fP \fBetc/scxmldump.cfg\fP \fB~/.seiscomp/global.cfg\fP \fB~/.seiscomp/scxmldump.cfg\fP .fi .sp .sp scxmldump inherits global options\&. .SH COMMAND-LINE OPTIONS .sp \fBscxmldump [options]\fP .SS Generic .INDENT 0.0 .TP .B \-h, \-\-help Show help message. .UNINDENT .INDENT 0.0 .TP .B \-V, \-\-version Show version information. .UNINDENT .INDENT 0.0 .TP .B \-\-config\-file arg Use alternative configuration file. When this option is used the loading of all stages is disabled. Only the given configuration file is parsed and used. To use another name for the configuration create a symbolic link of the application or copy it. Example: scautopick \-> scautopick2. .UNINDENT .INDENT 0.0 .TP .B \-\-plugins arg Load given plugins. .UNINDENT .INDENT 0.0 .TP .B \-D, \-\-daemon Run as daemon. This means the application will fork itself and doesn\(aqt need to be started with &. .UNINDENT .INDENT 0.0 .TP .B \-\-auto\-shutdown arg Enable/disable self\-shutdown because a master module shutdown. This only works when messaging is enabled and the master module sends a shutdown message (enabled with \-\-start\-stop\-msg for the master module). .UNINDENT .INDENT 0.0 .TP .B \-\-shutdown\-master\-module arg Set the name of the master\-module used for auto\-shutdown. This is the application name of the module actually started. If symlinks are used, then it is the name of the symlinked application. .UNINDENT .INDENT 0.0 .TP .B \-\-shutdown\-master\-username arg Set the name of the master\-username of the messaging used for auto\-shutdown. If "shutdown\-master\-module" is given as well, this parameter is ignored. .UNINDENT .SS Verbosity .INDENT 0.0 .TP .B \-\-verbosity arg Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info, 4:debug. .UNINDENT .INDENT 0.0 .TP .B \-v, \-\-v Increase verbosity level (may be repeated, eg. \-vv). .UNINDENT .INDENT 0.0 .TP .B \-q, \-\-quiet Quiet mode: no logging output. .UNINDENT .INDENT 0.0 .TP .B \-\-component arg Limit the logging to a certain component. This option can be given more than once. .UNINDENT .INDENT 0.0 .TP .B \-s, \-\-syslog Use syslog logging backend. The output usually goes to /var/lib/messages. .UNINDENT .INDENT 0.0 .TP .B \-l, \-\-lockfile arg Path to lock file. .UNINDENT .INDENT 0.0 .TP .B \-\-console arg Send log output to stdout. .UNINDENT .INDENT 0.0 .TP .B \-\-debug Execute in debug mode. Equivalent to \-\-verbosity=4 \-\-console=1 . .UNINDENT .INDENT 0.0 .TP .B \-\-log\-file arg Use alternative log file. .UNINDENT .SS Messaging .INDENT 0.0 .TP .B \-u, \-\-user arg Overrides configuration parameter \fBconnection.username\fP\&. .UNINDENT .INDENT 0.0 .TP .B \-H, \-\-host arg Overrides configuration parameter \fBconnection.server\fP\&. .UNINDENT .INDENT 0.0 .TP .B \-t, \-\-timeout arg Overrides configuration parameter \fBconnection.timeout\fP\&. .UNINDENT .INDENT 0.0 .TP .B \-g, \-\-primary\-group arg Overrides configuration parameter \fBconnection.primaryGroup\fP\&. .UNINDENT .INDENT 0.0 .TP .B \-S, \-\-subscribe\-group arg A group to subscribe to. This option can be given more than once. .UNINDENT .INDENT 0.0 .TP .B \-\-content\-type arg Overrides configuration parameter \fBconnection.contentType\fP\&. .UNINDENT .INDENT 0.0 .TP .B \-\-start\-stop\-msg arg Set sending of a start and a stop message. .UNINDENT .SS Database .INDENT 0.0 .TP .B \-\-db\-driver\-list List all supported database drivers. .UNINDENT .INDENT 0.0 .TP .B \-d, \-\-database arg The database connection string, format: \fI\%service://user:pwd@host/database\fP\&. "service" is the name of the database driver which can be queried with "\-\-db\-driver\-list". .UNINDENT .INDENT 0.0 .TP .B \-\-config\-module arg The config module to use. .UNINDENT .INDENT 0.0 .TP .B \-\-inventory\-db arg Load the inventory from the given database or file, format: [\fI\%service://]location\fP . .UNINDENT .INDENT 0.0 .TP .B \-\-config\-db arg Load the configuration from the given database or file, format: [\fI\%service://]location\fP . .UNINDENT .SS Dump .INDENT 0.0 .TP .B \-\-listen Enable server mode which listens to the message server for incoming events and dumps each received add/update. .UNINDENT .INDENT 0.0 .TP .B \-I, \-\-inventory Dump the inventory. .UNINDENT .INDENT 0.0 .TP .B \-\-without\-station\-groups Remove all station groups from inventory. .UNINDENT .INDENT 0.0 .TP .B \-\-stations sta\-list If inventory is exported filter the stations to export where each item is in format net[.{sta|*}]. .UNINDENT .INDENT 0.0 .TP .B \-C, \-\-config Dump the configuration database. .UNINDENT .INDENT 0.0 .TP .B \-J, \-\-journal Dump the journal. In combination with \-E only corresponding journal entries are included. .UNINDENT .INDENT 0.0 .TP .B \-R, \-\-routing Dump the routing database. .UNINDENT .INDENT 0.0 .TP .B \-Y, \-\-availability Dump data availability information. .UNINDENT .INDENT 0.0 .TP .B \-\-with\-segments Dump individual data segments. .UNINDENT .INDENT 0.0 .TP .B \-O, \-\-origin ID Origin public ID(s) to dump. Multiple origins may be specified as a comma\-separated list. .UNINDENT .INDENT 0.0 .TP .B \-E, \-\-event ID Event public ID(s) to dump. Multiple events may be specified as a comma\-separated list. .UNINDENT .INDENT 0.0 .TP .B \-P, \-\-with\-picks Dump associated picks along with origins. .UNINDENT .INDENT 0.0 .TP .B \-A, \-\-with\-amplitudes Dump associated amplitudes along with magnitudes. .UNINDENT .INDENT 0.0 .TP .B \-M, \-\-with\-magnitudes Dump station magnitudes. .UNINDENT .INDENT 0.0 .TP .B \-F, \-\-with\-focal\-mechanism Dump focal mechanisms of events. .UNINDENT .INDENT 0.0 .TP .B \-a, \-\-ignore\-arrivals Do not dump arrivals part of origins. .UNINDENT .INDENT 0.0 .TP .B \-\-ignore\-magnitudes Do not export (network) magnitudes of origins. This option is most useful in combination with \-O to only export the location information. .UNINDENT .INDENT 0.0 .TP .B \-p, \-\-preferred\-only When exporting events only the preferred origin, the preferred magnitude and the preferred focal mechanism will be dumped. .UNINDENT .INDENT 0.0 .TP .B \-m, \-\-all\-magnitudes If only the preferred origin is exported, all magnitudes for this origin will be dumped. .UNINDENT .SS Output .INDENT 0.0 .TP .B \-f, \-\-formatted Use formatted XML output. Otherwise all XML is printed on one line. .UNINDENT .INDENT 0.0 .TP .B \-o, \-\-output The output file. Default is stdout. .UNINDENT .INDENT 0.0 .TP .B \-\-prepend\-datasize Prepend a line with the length of the XML data. .UNINDENT .SH AUTHOR gempa GmbH, GFZ Potsdam .SH COPYRIGHT gempa GmbH, GFZ Potsdam .\" Generated by docutils manpage writer. .