<?xml version="1.0" encoding="UTF-8"?>
|
||
|
<seiscomp>
|
||
|
<plugin name="MN">
|
||
|
<extends>global</extends>
|
||
|
<description>
|
||
|
Nuttli magnitude for Canada and other Cratonic regions
|
||
|
</description>
|
||
|
<configuration>
|
||
|
<group name="amplitudes">
|
||
|
<group name="MN">
|
||
|
<description>
|
||
|
Amplitude control parameters for MN (Nuttli magnitude).
|
||
|
</description>
|
||
|
<parameter name="velocityModel" type="string" default="iasp91">
|
||
|
<description>
|
||
|
The travel time table set compiled for LocSAT. The tables
|
||
|
are located in "share/locsat/tables/[vmodel].*".
|
||
|
</description>
|
||
|
</parameter>
|
||
|
</group>
|
||
|
</group>
|
||
|
<group name="magnitudes">
|
||
|
<group name="MN">
|
||
|
<description>
|
||
|
Regionalization of MN (Nuttli magnitude).
|
||
|
</description>
|
||
|
<parameter name="region" type="path" default="@DATADIR@/magnitudes/MN/MN.bna">
|
||
|
<description>
|
||
|
The path to the BNA file which defines the valid region
|
||
|
for the MN magnitude. Note that the entire path from
|
||
|
source to receiver must lie entirely within the polygon(s).
|
||
|
</description>
|
||
|
</parameter>
|
||
|
</group>
|
||
|
</group>
|
||
|
</configuration>
|
||
|
</plugin>
|
||
|
<binding name="MN" module="global">
|
||
|
<description>
|
||
|
</description>
|
||
|
<configuration>
|
||
|
<group name="amplitudes">
|
||
|
<group name="MN">
|
||
|
<description>
|
||
|
Parameters for measuring AMN amplitudes.
|
||
|
</description>
|
||
|
<parameter name="rms" type="boolean" default="false">
|
||
|
<description>
|
||
|
Whether to use RMS ratio of signal and noise window for
|
||
|
SNR computation or the ration of the peak-trough
|
||
|
amplitudes of either window.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="filter" type="string">
|
||
|
<description>
|
||
|
The configurable filter such that the V measurement is
|
||
|
made on a filtered trace. By default, filtering is not
|
||
|
enabled.
|
||
|
|
||
|
See https://docs.gempa.de/seiscomp/current/base/filter-grammar.html
|
||
|
for how to specify the filter.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="Vmin" type="double" default="3.2" unit="km/s">
|
||
|
<description>
|
||
|
The minimum phase velocity used to determine the signal
|
||
|
window end.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="Vmax" type="double" default="3.6" unit="km/s">
|
||
|
<description>
|
||
|
The maximum phase velocity used to determine the signal
|
||
|
window start.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="snrWindowSeconds" type="double" default="10" unit="s">
|
||
|
<description>
|
||
|
The length of the SNR window.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="noiseWindowPreSeconds" type="double" default="0" unit="s">
|
||
|
<description>
|
||
|
The offset of the noise window. A positive value will move
|
||
|
the computed noise window to the left on the time axis,
|
||
|
a negative value will move it to the right on the time axis.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="signalStartPriorities" type="list:string" default="Lg,Sg,Sn,S,Vmax">
|
||
|
<description>
|
||
|
The priority list of phase onsets to compute the signal
|
||
|
start window. Except for Vmin and Vmax, associated phases
|
||
|
(arrivals) must be present in the origin for this
|
||
|
particular phase. Picked phases are only considered if
|
||
|
the origin is a manual origin or the pick is a
|
||
|
manual pick. The first value in the list which can be
|
||
|
retrieved or computed, is selected.
|
||
|
|
||
|
Allowed tokens: Pg, Pn, P, Sg, Sn, S, Lg, Rg, Vmin, Vmax
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="signalEndPriorities" type="list:string" default="Rg,Vmin">
|
||
|
<description>
|
||
|
The priority list of phase onsets to compute the signal
|
||
|
end window. Except for Vmin and Vmax, associated phases
|
||
|
(arrivals) must be present in the origin for this
|
||
|
particular phase. Picked phases are only considered if
|
||
|
the origin is a manual origin or the pick is a
|
||
|
manual pick. The first value in the list which can be
|
||
|
retrieved or computed, is selected.
|
||
|
|
||
|
Allowed tokens: Pg, Pn, P, Sg, Sn, S, Lg, Rg, Vmin, Vmax
|
||
|
</description>
|
||
|
</parameter>
|
||
|
</group>
|
||
|
</group>
|
||
|
<group name="magnitudes">
|
||
|
<group name="MN">
|
||
|
<description>
|
||
|
Parameters for computing MN magnitudes from AMN amplitudes.
|
||
|
</description>
|
||
|
<parameter name="minSNR" type="double" default="2">
|
||
|
<description>
|
||
|
The minimum SNR required for a magnitude to pass
|
||
|
the QC check. The station magnitude will be computed
|
||
|
anyway but if the SNR is below this threshold it will
|
||
|
be associated with weight zero and will not contribute
|
||
|
to the network magnitude.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="minPeriod" type="double" default="0.01" unit="s">
|
||
|
<description>
|
||
|
The minimum period required for a magnitude to pass
|
||
|
the QC check. The station magnitude will be computed
|
||
|
anyway but if the period is below this threshold it will
|
||
|
be associated with weight zero and will not contribute
|
||
|
to the network magnitude.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="maxPeriod" type="double" default="1.3" unit="s">
|
||
|
<description>
|
||
|
The maximum period allowed for a magnitude to pass
|
||
|
the QC check. The station magnitude will be computed
|
||
|
anyway but if the period is above this threshold it will
|
||
|
be associated with weight zero and will not contribute
|
||
|
to the network magnitude.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="minDist" type="double" default="0.5" unit="deg">
|
||
|
<description>
|
||
|
The minimum distance required for a magnitude to pass
|
||
|
the QC check. The station magnitude will be computed
|
||
|
anyway but if the distance is below this threshold it
|
||
|
will be associated with weight zero and will not contribute
|
||
|
to the network magnitude.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
<parameter name="maxDist" type="double" default="30" unit="deg">
|
||
|
<description>
|
||
|
The maximum distance allowed for a magnitude to be
|
||
|
computed. If the distance exceeds this threshold then
|
||
|
the computation will be canceled and no station
|
||
|
magnitude will be available at all.
|
||
|
</description>
|
||
|
</parameter>
|
||
|
</group>
|
||
|
</group>
|
||
|
</configuration>
|
||
|
</binding>
|
||
|