You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

116 lines
3.6 KiB
XML

<?xml version="1.0" encoding="UTF-8"?>
<seiscomp>
<plugin name="Md">
<extends>global</extends>
<description>
Duration magnitude plugin
</description>
</plugin>
<binding name="Md" module="global">
<description>
Duration magnitude plugin
</description>
<configuration>
<group name="magnitudes">
<group name="md">
<parameter name="seismo" type="int" default="9">
<description>
Default filter type to use before processing and after deconvolution. It's possible to set :
1 for a Wood-Anderson seismometer
2 for a 5sec generic Seismometer
3 for a WWSSN LP seismometer
4 for a WSSN SP seismometer
5 for a Generic Seismometer
6 for a Butterworth Low pass filter
7 for a Butterworth High pass filter
8 for a Butterworth Band pass filter
9 for a 1Hz eigen-frequency L4C seismometer
</description>
</parameter>
<parameter name="taper" type="double" default="5" unit="s">
<description>
taper applied to the signal
</description>
</parameter>
<parameter name="signal_length" type="double" default="150" unit="s">
<description>
signal length used to compute the duration magnitude
</description>
</parameter>
<parameter name="butterworth" type="string" default="&quot;3,1.5&quot;">
<description>
Butterworth filter parameter applied to the signal
</description>
</parameter>
<parameter name="depthmax" type="double" default="200" unit="km">
<description>
Maximum depth at which duration magnitude is valid
</description>
</parameter>
<parameter name="deltamax" type="double" default="400" unit="km">
<description>
Maximum distance between earthquake and station at which duration magnitude is valid
</description>
</parameter>
<parameter name="snrmin" type="double" default="1.2">
<description>
Signal to noise ratio below which the coda is reached
</description>
</parameter>
<parameter name="mdmax" type="double" default="5.0">
<description>
Maximum expected duration magnitude value
This is used to find how much data should be loaded for a given station by reversing the formula
</description>
</parameter>
<parameter name="fma" type="double" default="-0.87">
<description>
FMA regional coefficient
See Hypo2000 manual
</description>
</parameter>
<parameter name="fmb" type="double" default="2.0">
<description>
FMB regional coefficient
See Hypo2000 manual
</description>
</parameter>
<parameter name="fmd" type="double" default="0.0035">
<description>
FMD regional coefficient
See Hypo2000 manual
</description>
</parameter>
<parameter name="fmf" type="double" default="0.0">
<description>
FMF regional coefficient
See Hypo2000 manual
</description>
</parameter>
<parameter name="fmz" type="double" default="0.0">
<description>
FMZ regional coefficient
See Hypo2000 manual
</description>
</parameter>
<parameter name="linearcorrection" type="double" default="1.0">
<description>
Linear correction
</description>
</parameter>
<parameter name="offset" type="double" default="0.0">
<description>
Offset
</description>
</parameter>
<parameter name="stacor" type="double" default="0.0">
<description>
Station correction
</description>
</parameter>
</group>
</group>
</configuration>
</binding>
</seiscomp>