You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

313 lines
7.2 KiB
Groff

.\" Man page generated from reStructuredText.
.
.TH "SCSENDJOURNAL" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
.SH NAME
scsendjournal \- SeisComP Documentation
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.sp
\fBSend journaling information to the messaging to manipulate event parameter objects.\fP
.SH DESCRIPTION
.sp
scsendjournal sends journals to the scname messaging system.
Currently, journals can be used to command scevent\&.
The journals command scevent to manipulate event parameters according to
the \fI\%journal actions\fP which must be known to
scevent\&.
.sp
The actions allow to:
.INDENT 0.0
.IP \(bu 2
Create new events,
.IP \(bu 2
Modify event parameters,
.IP \(bu 2
Control the association of origins to events.
.UNINDENT
.SH SYNOPSIS
.sp
scsendjournal [opts] {objectID} {action} [parameters]
.SH ACTIONS
.sp
There are specific journal actions for handling non\-events and events. The documentation
of scevent contains a complete list of journals known to scevent\&.
.SS None\-event specific actions
.INDENT 0.0
.IP \(bu 2
\fBEvNewEvent\fP: Create a new event from origin with the provided origin ID.
The origin must be known to scevent\&.
.sp
Example: Create a new event from the
origin with given originID. Apply the action in the message system on \fIlocalhost\fP:
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
scsendjournal \-H localhost Origin#20170505130954.736019.318 EvNewEvent
.ft P
.fi
.UNINDENT
.UNINDENT
.UNINDENT
.SS Origin association
.INDENT 0.0
.IP \(bu 2
\fBEvGrabOrg\fP: Grab origin and move the origin to the event with the given eventID.
If the origins is already associated to another event, remove this reference
in the other event.
.IP \(bu 2
\fBEvMerge\fP: Merge events into one event.
.sp
Example: Merge all origins from the source event with eventID \fIeventS\fP into the
target event with eventID \fIeventT\fP\&. Remove event \fIeventS\fP\&. Apply the action in
the message system on \fIhost\fP:
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
scsendjournal \-H {host} {eventT} EvMerge {eventS}
.ft P
.fi
.UNINDENT
.UNINDENT
.IP \(bu 2
\fBEvSplitOrg\fP: Split origins to 2 events.
.UNINDENT
.SS Event parameters
.INDENT 0.0
.IP \(bu 2
\fBEvName\fP: Set \fIEventDescription\fP of type \fIearthquake name\fP\&.
.sp
Example, setting the name of the event with
eventID \fIgempa2021abcd\fP to \fIPetrinja\fP
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
scsendjournal \-H localhost gempa2020abcd EvName "Petrinja"
.ft P
.fi
.UNINDENT
.UNINDENT
.IP \(bu 2
\fBEvOpComment\fP: Set event operator\(aqs comment.
.IP \(bu 2
\fBEvPrefFocMecID\fP: Set event preferred focal mechanism.
.IP \(bu 2
\fBEvPrefMagTypev:\fP Set preferred magnitude type.
.IP \(bu 2
\fBEvPrefMw\fP: Set Mw from focal mechanism as preferred magnitude.
.IP \(bu 2
\fBEvPrefOrgAutomatic\fP: Set the preferred mode to \fIautomatic\fP corresponding to \fIunfix\fP in scolv.
.IP \(bu 2
\fBEvPrefOrgEvalMode\fP: Set preferred origin by evaluation mode.
.IP \(bu 2
\fBEvPrefOrgID\fP: Set preferred origin by ID.
.IP \(bu 2
\fBEvRefresh\fP: Select the preferred origin, the preferred magnitude, update
the region. Call processors loaded with plugins, e.g. the
evrc plugin for scevent.
.sp
Example:
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
scsendjournal \-H localhost gempa2021abcd EvRefresh
.ft P
.fi
.UNINDENT
.UNINDENT
.IP \(bu 2
\fBEvType\fP: Set event type.
.sp
Example: Set the type of the event with eventID \fIgempa2021abcd\fP to \fInuclear explosion\fP\&.
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
scsendjournal \-H localhost gempa2021abcd EvType "nuclear explosion"
.ft P
.fi
.UNINDENT
.UNINDENT
.IP \(bu 2
\fBEvTypeCertainty\fP: set event type certainty.
.UNINDENT
.SH COMMAND-LINE OPTIONS
.sp
\fBscsendjournal [opts] {objectID} {action} [parameters]\fP
.SS Generic
.INDENT 0.0
.TP
.B \-h, \-\-help
Show help message.
.UNINDENT
.INDENT 0.0
.TP
.B \-V, \-\-version
Show version information.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-file arg
Use alternative configuration file. When this option is
used the loading of all stages is disabled. Only the
given configuration file is parsed and used. To use
another name for the configuration create a symbolic
link of the application or copy it. Example:
scautopick \-> scautopick2.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-plugins arg
Load given plugins.
.UNINDENT
.INDENT 0.0
.TP
.B \-D, \-\-daemon
Run as daemon. This means the application will fork itself
and doesn\(aqt need to be started with &.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-auto\-shutdown arg
Enable/disable self\-shutdown because a master module shutdown.
This only works when messaging is enabled and the master
module sends a shutdown message (enabled with \-\-start\-stop\-msg
for the master module).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-module arg
Set the name of the master\-module used for auto\-shutdown.
This is the application name of the module actually
started. If symlinks are used, then it is the name of
the symlinked application.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-username arg
Set the name of the master\-username of the messaging
used for auto\-shutdown. If "shutdown\-master\-module" is
given as well, this parameter is ignored.
.UNINDENT
.SS Verbosity
.INDENT 0.0
.TP
.B \-\-verbosity arg
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
4:debug.
.UNINDENT
.INDENT 0.0
.TP
.B \-v, \-\-v
Increase verbosity level (may be repeated, eg. \-vv).
.UNINDENT
.INDENT 0.0
.TP
.B \-q, \-\-quiet
Quiet mode: no logging output.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-component arg
Limit the logging to a certain component. This option can
be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-s, \-\-syslog
Use syslog logging backend. The output usually goes to
/var/lib/messages.
.UNINDENT
.INDENT 0.0
.TP
.B \-l, \-\-lockfile arg
Path to lock file.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-console arg
Send log output to stdout.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-debug
Execute in debug mode.
Equivalent to \-\-verbosity=4 \-\-console=1 .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-log\-file arg
Use alternative log file.
.UNINDENT
.SS Messaging
.INDENT 0.0
.TP
.B \-u, \-\-user arg
Overrides configuration parameter \fBconnection.username\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-H, \-\-host arg
Overrides configuration parameter \fBconnection.server\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-t, \-\-timeout arg
Overrides configuration parameter \fBconnection.timeout\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-g, \-\-primary\-group arg
Overrides configuration parameter \fBconnection.primaryGroup\fP\&.
.UNINDENT
.INDENT 0.0
.TP
.B \-S, \-\-subscribe\-group arg
A group to subscribe to.
This option can be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-start\-stop\-msg arg
Set sending of a start and a stop message.
.UNINDENT
.SH AUTHOR
gempa GmbH, GFZ Potsdam
.SH COPYRIGHT
gempa GmbH, GFZ Potsdam
.\" Generated by docutils manpage writer.
.