.\" Man page generated from reStructuredText.
|
|
|
.
|
|
|
.TH "SCMAG" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
|
|
|
.SH NAME
|
|
|
scmag \- SeisComP Documentation
|
|
|
.
|
|
|
.nr rst2man-indent-level 0
|
|
|
.
|
|
|
.de1 rstReportMargin
|
|
|
\\$1 \\n[an-margin]
|
|
|
level \\n[rst2man-indent-level]
|
|
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
|
-
|
|
|
\\n[rst2man-indent0]
|
|
|
\\n[rst2man-indent1]
|
|
|
\\n[rst2man-indent2]
|
|
|
..
|
|
|
.de1 INDENT
|
|
|
.\" .rstReportMargin pre:
|
|
|
. RS \\$1
|
|
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
|
|
. nr rst2man-indent-level +1
|
|
|
.\" .rstReportMargin post:
|
|
|
..
|
|
|
.de UNINDENT
|
|
|
. RE
|
|
|
.\" indent \\n[an-margin]
|
|
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
|
.nr rst2man-indent-level -1
|
|
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
|
|
..
|
|
|
.sp
|
|
|
\fBCalculates magnitudes of different types.\fP
|
|
|
.SH DESCRIPTION
|
|
|
.sp
|
|
|
The purpose of scmag is to compute magnitudes from pre\-computed amplitudes.
|
|
|
Instead it takes amplitudes and origins as input and produces StationMagnitudes
|
|
|
and (network) Magnitudes as output. It does not access waveforms.
|
|
|
The resulting magnitudes are sent to the "MAGNITUDE" group. scmag doesn’t access
|
|
|
any waveforms. It only uses amplitudes previously calculated.
|
|
|
.sp
|
|
|
The purpose of scmag is the decoupling of magnitude computation from amplitude
|
|
|
measurements. This allows several modules to generate amplitudes concurrently,
|
|
|
like scautopick or scamp\&. As soon as an origin comes in, the amplitudes related
|
|
|
to the picks are taken either from the memory buffer or the database to compute
|
|
|
the magnitudes.
|
|
|
.SS Relationship between amplitudes and origins
|
|
|
.sp
|
|
|
scmag makes use of the fact that origins sent by scautoloc, scolv
|
|
|
or other modules include
|
|
|
the complete set of arrivals, which reference picks used for origin computation.
|
|
|
The picks in turn are referenced by a number of amplitudes, some of which are
|
|
|
relevant for magnitude computation.
|
|
|
.sp
|
|
|
Read the scamp documentation for more details on amplitude measurements.
|
|
|
.SS Primary magnitudes
|
|
|
.sp
|
|
|
Primary magnitudes are computed from amplitudes and station\-event distances.
|
|
|
Currently the following primary magnitude types are implemented.
|
|
|
.SS Local distances
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B Md
|
|
|
Duration magnitude as described in HYPOINVERSE (klein\-2002).
|
|
|
.TP
|
|
|
.B Mjma
|
|
|
Mjma is computed on displacement data using body waves of period < 30s.
|
|
|
.TP
|
|
|
.B ML
|
|
|
Local (Richter) magnitude calculated on the horizontal components using a
|
|
|
correction term to fit with the standard ML (richter\-1935).
|
|
|
.TP
|
|
|
.B MLc
|
|
|
Local custom magnitude calculated on the horizontal components according to
|
|
|
Hessian Earthquake Service and stange\-2006
|
|
|
.TP
|
|
|
.B MLh
|
|
|
Local magnitude calculated on the horizontal components according to SED
|
|
|
specifications.
|
|
|
.TP
|
|
|
.B MLv
|
|
|
Local magnitude calculated on the vertical component using a correction term
|
|
|
to fit with the standard ML.
|
|
|
.TP
|
|
|
.B MLr
|
|
|
Local magnitude calculated from MLv amplitudes based on GNS/GEONET specifications
|
|
|
for New Zealand (ristau\-2016).
|
|
|
.TP
|
|
|
.B MN
|
|
|
Nuttli magnitude for Canada and other Cratonic regions (nuttli\-1973).
|
|
|
.UNINDENT
|
|
|
.SS Teleseismic distances
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B mb
|
|
|
Narrow band body wave magnitude measured on a WWSSN\-SP filtered trace
|
|
|
.TP
|
|
|
.B mBc
|
|
|
Cumulative body wave magnitude
|
|
|
.TP
|
|
|
.B mB
|
|
|
Broad band body wave magnitude after bormann\-2008
|
|
|
.TP
|
|
|
.B Mwp
|
|
|
The body wave magnitude of tsuboi\-1995
|
|
|
.TP
|
|
|
.B Ms_20
|
|
|
Surface\-wave magnitude at 20 s period
|
|
|
.TP
|
|
|
.B Ms(BB)
|
|
|
Broad band surface\-wave magnitude
|
|
|
.UNINDENT
|
|
|
.SS Derived magnitudes
|
|
|
.sp
|
|
|
Additionally, scmag derives the following magnitudes from primary magnitudes:
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B Mw(mB)
|
|
|
Estimation of the moment magnitude Mw based on mB using the Mw vs. mB
|
|
|
regression of bormann\-2008
|
|
|
.TP
|
|
|
.B Mw(Mwp)
|
|
|
Estimation of the moment magnitude Mw based on Mwp using the Mw vs. Mwp
|
|
|
regression of whitmore\-2002
|
|
|
.TP
|
|
|
.B M
|
|
|
Summary magnitude, which consists of a weighted average of the individual
|
|
|
magnitudes and attempts to be a best possible compromise between all magnitudes.
|
|
|
See below for configuration and also scevent for how to add the summary magnitude
|
|
|
to the list of possible preferred magnitudes or how to make it always preferred.
|
|
|
.sp
|
|
|
More details are given in the \fI\%section Summary magnitude\fP\&.
|
|
|
.TP
|
|
|
.B Mw(avg)
|
|
|
Estimation of the moment magnitude Mw based on a weighted average of other
|
|
|
magnitudes, currently MLv, mb and Mw(mB), in future possibly other magnitudes as
|
|
|
well, especially those suitable for very large events. The purpose of Mw(avg) is
|
|
|
to have, at any stage during the processing, a “best possible” estimation of the
|
|
|
magnitude by combining all available magnitudes into a single, weighted average.
|
|
|
Initially the average will consist of only MLv and/or mb measurements, but as soon
|
|
|
as Mw(mB) measurements become available, these (and in future other large\-event
|
|
|
magnitudes) become progressively more weight in the average.
|
|
|
.UNINDENT
|
|
|
.sp
|
|
|
If an amplitude is updated, the corresponding magnitude is updated as well.
|
|
|
This allows the computation of preliminary, real\-time magnitudes even before
|
|
|
the full length of the P coda is available.
|
|
|
.SH STATION MAGNITUDES
|
|
|
.sp
|
|
|
Station magnitudes of a \fI\%particular magnitude type\fP are
|
|
|
calculated based on amplitude values
|
|
|
considered by this magnitude type and the distance between the event and the station
|
|
|
at which the amplitude was measured. Typically, epicentral distance is used.
|
|
|
.sp
|
|
|
\fBNOTE:\fP
|
|
|
.INDENT 0.0
|
|
|
.INDENT 3.5
|
|
|
Usually station magnitudes use amplitudes of the same type. However, some magnitude
|
|
|
consider amplitudes of another type. E.g. MLr
|
|
|
uses amplitudes computed for MLv\&.
|
|
|
.UNINDENT
|
|
|
.UNINDENT
|
|
|
.SH NETWORK MAGNITUDES
|
|
|
.sp
|
|
|
The network magnitude is a magnitude value summarizing several \fI\%station magnitudes\fP
|
|
|
values of one origin\&.
|
|
|
Different methods are available for summarizing the station magnitudes:
|
|
|
.INDENT 0.0
|
|
|
.IP \(bu 2
|
|
|
mean: the usual mean value
|
|
|
.IP \(bu 2
|
|
|
trimmed mean value:
|
|
|
To stabilize the network magnitudes the smallest and the largest 12.5% of the
|
|
|
station magnitude values are removed before computing the mean.
|
|
|
.IP \(bu 2
|
|
|
median: the usual median value
|
|
|
.IP \(bu 2
|
|
|
median trimmed mean:
|
|
|
Removing all station magnitudes with a distance greater than 0.5 (default)
|
|
|
from the median of all station magnitudes and computing the mean of all
|
|
|
remaining station magnitudes.
|
|
|
.UNINDENT
|
|
|
.sp
|
|
|
Default values apply for each magnitude type.
|
|
|
In scolv the methods, the stations magnitudes and other parameters can be
|
|
|
selected interactively.
|
|
|
.SH SUMMARY MAGNITUDE
|
|
|
.sp
|
|
|
scmag can compute a summary magnitude as a weighted sum from all available
|
|
|
\fI\%network magnitudes\fP\&.
|
|
|
This magnitude is typically called \fBM\fP as configured in
|
|
|
\fI\%summaryMagnitude.type\fP\&.
|
|
|
.sp
|
|
|
It is computed as a weighted average over the available magnitudes:
|
|
|
.sp
|
|
|
.ce
|
|
|
M = \efrac{\esum w_{i} M_{i}}{\esum w_i}
|
|
|
|
|
|
w_{i} = a_i stationCount(M_{i}) + b_i
|
|
|
.ce 0
|
|
|
.sp
|
|
|
The coefficients a and b can be configured per magnitude type by
|
|
|
\fI\%summaryMagnitude.coefficients.a\fP
|
|
|
and \fI\%summaryMagnitude.coefficients.b\fP, respectively.
|
|
|
Furthermore each magnitude type can be specifically added to or excluded from the
|
|
|
summary magnitude calculation
|
|
|
as defined in \fI\%summaryMagnitude.whitelist\fP or
|
|
|
\fI\%summaryMagnitude.blacklist\fP, respectively.
|
|
|
.sp
|
|
|
\fBNOTE:\fP
|
|
|
.INDENT 0.0
|
|
|
.INDENT 3.5
|
|
|
While the magnitudes are computed by scmag the decision about the preferred
|
|
|
magnitude of an event is made by scevent\&.
|
|
|
.UNINDENT
|
|
|
.UNINDENT
|
|
|
.SH PREFERRED MAGNITUDE
|
|
|
.sp
|
|
|
The preferred magnitude of an event is set automatically by scevent
|
|
|
or interactively in scolv\&. It can be any network magnitude or the summary
|
|
|
magnitude.
|
|
|
.SH MODULE CONFIGURATION
|
|
|
.nf
|
|
|
\fBetc/defaults/global.cfg\fP
|
|
|
\fBetc/defaults/scmag.cfg\fP
|
|
|
\fBetc/global.cfg\fP
|
|
|
\fBetc/scmag.cfg\fP
|
|
|
\fB~/.seiscomp/global.cfg\fP
|
|
|
\fB~/.seiscomp/scmag.cfg\fP
|
|
|
.fi
|
|
|
.sp
|
|
|
.sp
|
|
|
scmag inherits global options\&.
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B magnitudes
|
|
|
Default: \fBMLv, mb, mB, Mwp\fP
|
|
|
.sp
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
The magnitude types to be calculated. Station magnitudes are
|
|
|
computed from their amplitudes, network magnitudes from their
|
|
|
station magnitudes.
|
|
|
.UNINDENT
|
|
|
.sp
|
|
|
\fBNOTE:\fP
|
|
|
.INDENT 0.0
|
|
|
.INDENT 3.5
|
|
|
\fBmagnitudes.*\fP
|
|
|
\fIGeneral parameters for computing magnitudes. Others are configured\fP
|
|
|
\fIby global binding parameters for specific magnitude types.\fP
|
|
|
.UNINDENT
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B magnitudes.average
|
|
|
Default: \fBdefault\fP
|
|
|
.sp
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
The methods for computing the network magnitude
|
|
|
from station magnitudes. Exactly one method per
|
|
|
magnitude can be configured.
|
|
|
To define the averaging method per magnitude type append
|
|
|
the type after colon, e.g.:
|
|
|
"magnitudes.average = default, MLv:median"
|
|
|
.sp
|
|
|
default: Compute the mean if less than 4 contributed
|
|
|
station magnitudes exist. Otherwise apply a trimmed mean
|
|
|
of 25%.
|
|
|
.sp
|
|
|
Options are "default", "mean",
|
|
|
"median", "trimmedMean" and
|
|
|
"medianTrimmedMean".
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B connection.sendInterval
|
|
|
Default: \fB1\fP
|
|
|
.sp
|
|
|
Type: \fIint\fP
|
|
|
.sp
|
|
|
Unit: \fIs\fP
|
|
|
.sp
|
|
|
Interval between 2 sending processes. The interval controls
|
|
|
how often information is updated.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B connection.minimumArrivalWeight
|
|
|
Default: \fB0.5\fP
|
|
|
.sp
|
|
|
Type: \fIdouble\fP
|
|
|
.sp
|
|
|
The minimum weight of an arrival for an associated amplitude
|
|
|
to be used for calculating a magnitude.
|
|
|
.UNINDENT
|
|
|
.sp
|
|
|
\fBNOTE:\fP
|
|
|
.INDENT 0.0
|
|
|
.INDENT 3.5
|
|
|
\fBsummaryMagnitude.*\fP
|
|
|
\fIThe summary magnitude is the weighted average from all\fP
|
|
|
\fIdefined network magnitude types: Single network magnitude values\fP
|
|
|
\fIare multiplied with their magnitude\-type specific weight and\fP
|
|
|
\fIsummed up. The resulting sum is divided by the sum of all weights.\fP
|
|
|
.UNINDENT
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.enabled
|
|
|
Default: \fBtrue\fP
|
|
|
.sp
|
|
|
Type: \fIboolean\fP
|
|
|
.sp
|
|
|
Enables summary magnitude calculation.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.type
|
|
|
Default: \fBM\fP
|
|
|
.sp
|
|
|
Type: \fIstring\fP
|
|
|
.sp
|
|
|
Define the type/name of the summary magnitude.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.minStationCount
|
|
|
Default: \fB4\fP
|
|
|
.sp
|
|
|
Type: \fIint\fP
|
|
|
.sp
|
|
|
This is the minimum station magnitude required for any
|
|
|
magnitude to contribute to the summary magnitude at all. If
|
|
|
this is set to 4, then no magnitude with less than 4 station
|
|
|
magnitudes is taken into consideration even if this results
|
|
|
in no summary magnitude at all. For this reason, the default
|
|
|
here is 1 but in a purely automatic system it should be
|
|
|
higher, at least 4 is recommended.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.blacklist
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
Define the magnitude types to be excluded from the summary
|
|
|
magnitude calculation.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.whitelist
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
Define the magnitude types to be included in the summary
|
|
|
magnitude calculation.
|
|
|
.UNINDENT
|
|
|
.sp
|
|
|
\fBNOTE:\fP
|
|
|
.INDENT 0.0
|
|
|
.INDENT 3.5
|
|
|
\fBsummaryMagnitude.coefficients.*\fP
|
|
|
\fIThe coefficients defining the weight of network magnitudes\fP
|
|
|
\fIfor calculating the summary magnitude.\fP
|
|
|
\fIWeight = a * magnitudeStationCount + b.\fP
|
|
|
.UNINDENT
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.coefficients.a
|
|
|
Default: \fB0, Mw(mB):0.4, Mw(Mwp):0.4\fP
|
|
|
.sp
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
Define the coefficients a. To define the value per magnitude
|
|
|
type append the type after colon. A value without a
|
|
|
type defines the default value.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B summaryMagnitude.coefficients.b
|
|
|
Default: \fB1, MLv:2, Mw(mB):\-1, Mw(Mwp):\-1\fP
|
|
|
.sp
|
|
|
Type: \fIlist:string\fP
|
|
|
.sp
|
|
|
Define the coefficients b. To define the value per magnitude
|
|
|
type append the type after colon. A value without a
|
|
|
type defines the default value.
|
|
|
.UNINDENT
|
|
|
.SH COMMAND-LINE OPTIONS
|
|
|
.SS Generic
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-h, \-\-help
|
|
|
Show help message.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-V, \-\-version
|
|
|
Show version information.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-config\-file arg
|
|
|
Use alternative configuration file. When this option is
|
|
|
used the loading of all stages is disabled. Only the
|
|
|
given configuration file is parsed and used. To use
|
|
|
another name for the configuration create a symbolic
|
|
|
link of the application or copy it. Example:
|
|
|
scautopick \-> scautopick2.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-plugins arg
|
|
|
Load given plugins.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-D, \-\-daemon
|
|
|
Run as daemon. This means the application will fork itself
|
|
|
and doesn\(aqt need to be started with &.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-auto\-shutdown arg
|
|
|
Enable/disable self\-shutdown because a master module shutdown.
|
|
|
This only works when messaging is enabled and the master
|
|
|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
|
|
for the master module).
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-shutdown\-master\-module arg
|
|
|
Set the name of the master\-module used for auto\-shutdown.
|
|
|
This is the application name of the module actually
|
|
|
started. If symlinks are used, then it is the name of
|
|
|
the symlinked application.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-shutdown\-master\-username arg
|
|
|
Set the name of the master\-username of the messaging
|
|
|
used for auto\-shutdown. If "shutdown\-master\-module" is
|
|
|
given as well, this parameter is ignored.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-x, \-\-expiry time
|
|
|
Time span in hours after which objects expire.
|
|
|
.UNINDENT
|
|
|
.SS Verbosity
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-verbosity arg
|
|
|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
|
|
4:debug.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-v, \-\-v
|
|
|
Increase verbosity level (may be repeated, eg. \-vv).
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-q, \-\-quiet
|
|
|
Quiet mode: no logging output.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-component arg
|
|
|
Limit the logging to a certain component. This option can
|
|
|
be given more than once.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-s, \-\-syslog
|
|
|
Use syslog logging backend. The output usually goes to
|
|
|
/var/lib/messages.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-l, \-\-lockfile arg
|
|
|
Path to lock file.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-console arg
|
|
|
Send log output to stdout.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-debug
|
|
|
Execute in debug mode.
|
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-log\-file arg
|
|
|
Use alternative log file.
|
|
|
.UNINDENT
|
|
|
.SS Messaging
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-u, \-\-user arg
|
|
|
Overrides configuration parameter \fBconnection.username\fP\&.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-H, \-\-host arg
|
|
|
Overrides configuration parameter \fBconnection.server\fP\&.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-t, \-\-timeout arg
|
|
|
Overrides configuration parameter \fBconnection.timeout\fP\&.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-g, \-\-primary\-group arg
|
|
|
Overrides configuration parameter \fBconnection.primaryGroup\fP\&.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-S, \-\-subscribe\-group arg
|
|
|
A group to subscribe to.
|
|
|
This option can be given more than once.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-content\-type arg
|
|
|
Overrides configuration parameter \fBconnection.contentType\fP\&.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-start\-stop\-msg arg
|
|
|
Set sending of a start and a stop message.
|
|
|
.UNINDENT
|
|
|
.SS Database
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-db\-driver\-list
|
|
|
List all supported database drivers.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-d, \-\-database arg
|
|
|
The database connection string, format:
|
|
|
\fI\%service://user:pwd@host/database\fP\&.
|
|
|
"service" is the name of the database driver which
|
|
|
can be queried with "\-\-db\-driver\-list".
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-config\-module arg
|
|
|
The config module to use.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-inventory\-db arg
|
|
|
Load the inventory from the given database or file, format:
|
|
|
[\fI\%service://]location\fP .
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-db\-disable
|
|
|
Do not use the database at all
|
|
|
.UNINDENT
|
|
|
.SS Input
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-ep file
|
|
|
Defines an event parameters XML file to be read and processed. This
|
|
|
implies offline mode and only processes all origins contained
|
|
|
in that file. It computes station magnitudes for all picks associated
|
|
|
with an origin where amplitudes are available and the corresponding
|
|
|
network magnitudes. Station and network magnitudes having the
|
|
|
evaluation status set are ignored. Use the \-\-force to include those
|
|
|
magnitudes. It outputs an XML text adding the station\-
|
|
|
and network magnitudes to the input XML file.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-reprocess
|
|
|
Reprocess also station and network magnitudes with an evaluation
|
|
|
status set but do not change original weights. New
|
|
|
contributions are added with weight 0.
|
|
|
.UNINDENT
|
|
|
.SS Reprocess
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-static
|
|
|
With that flag all existing station magnitudes are recomputed
|
|
|
based on their associated amplitudes. If an amplitude cannot
|
|
|
be accessed, no station magnitude is updated.
|
|
|
Network magnitudes are recomputed based on their station
|
|
|
magnitude contributions. No new objects will
|
|
|
be created in this mode, it only updates values and weights.
|
|
|
The method to accumulate the station magnitudes to form the network
|
|
|
magnitude will be read from the existing object and replicated.
|
|
|
If it cannot be interpreted then the configured default for this
|
|
|
magnitude type will be used instead. Weights of station magnitudes
|
|
|
will be changed according to the accumulation method of the
|
|
|
network magnitude.
|
|
|
.UNINDENT
|
|
|
.INDENT 0.0
|
|
|
.TP
|
|
|
.B \-\-keep\-weights
|
|
|
Keep the original weights in combination with \-\-static.
|
|
|
.UNINDENT
|
|
|
.SH AUTHOR
|
|
|
gempa GmbH, GFZ Potsdam
|
|
|
.SH COPYRIGHT
|
|
|
gempa GmbH, GFZ Potsdam
|
|
|
.\" Generated by docutils manpage writer.
|
|
|
.
|