You cannot select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
762 lines
15 KiB
Groff
762 lines
15 KiB
Groff
.\" Man page generated from reStructuredText.
|
|
.
|
|
.TH "SCHELI" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
|
|
.SH NAME
|
|
scheli \- SeisComP Documentation
|
|
.
|
|
.nr rst2man-indent-level 0
|
|
.
|
|
.de1 rstReportMargin
|
|
\\$1 \\n[an-margin]
|
|
level \\n[rst2man-indent-level]
|
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
-
|
|
\\n[rst2man-indent0]
|
|
\\n[rst2man-indent1]
|
|
\\n[rst2man-indent2]
|
|
..
|
|
.de1 INDENT
|
|
.\" .rstReportMargin pre:
|
|
. RS \\$1
|
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
|
. nr rst2man-indent-level +1
|
|
.\" .rstReportMargin post:
|
|
..
|
|
.de UNINDENT
|
|
. RE
|
|
.\" indent \\n[an-margin]
|
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.nr rst2man-indent-level -1
|
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
|
..
|
|
.sp
|
|
\fBReal\-time helicorder view for one stream.\fP
|
|
.SH DESCRIPTION
|
|
.sp
|
|
\fBscheli\fP visualizes waveforms from a single stream or multiple stations
|
|
mimicking a drum\-recorder plot (see \fI\%scheli in GUI mode\fP):
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
\fBscheli\fP plots one configurable trace in helicorder style in the
|
|
GUI (\fI\%GUI mode\fP).
|
|
.IP \(bu 2
|
|
Configurable GUI: trace colors, visualized time spans, number of rows, data filtering,
|
|
amplitude ranges and much more.
|
|
.IP \(bu 2
|
|
Automatic image capturing: Capture helicorder images at configurable time intervals
|
|
of one trace in \fI\%GUI mode\fP or a set of multiple channels in
|
|
\fI\%capture mode\fP\&.
|
|
The images can be used, e.g. for showing data images on web sites.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.INDENT 2.5
|
|
[image]
|
|
scheli in GUI mode.UNINDENT
|
|
.UNINDENT
|
|
.SH EXAMPLES
|
|
.INDENT 0.0
|
|
.IP 1. 3
|
|
\fBGUI mode \- Simple helicorder window:\fP
|
|
.INDENT 3.0
|
|
.IP \(bu 2
|
|
Learn about the plenty command\-line options for \fBscheli\fP:
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scheli \-h
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.IP \(bu 2
|
|
Start \fBscheli\fP with the configured values and informative debug output:
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scheli \-\-debug
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.IP \(bu 2
|
|
Let \fBscheli\fP show data from the CX station PB01 for the previous 5 hours
|
|
overriding configuration by command\-line paramaters:
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scheli \-\-stream CX.PB01..HHZ \-\-rows 10
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.IP \(bu 2
|
|
Define the data request window by end time and duration; scale traces to the
|
|
maximum amplitude per row:
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scheli \-\-stream IU.TSUM.00.BHZ \-\-end\-time "2021\-04\-22 14:00:00" \-\-time\-span 600 \-\-amp\-scaling row
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.IP 2. 3
|
|
\fBCapture mode \- Image capturing:\fP
|
|
.sp
|
|
Capture the helicorder plot for 3 stations in intervals of 10 seconds.
|
|
The data is retrieved using seedlink and the plots are stored as PNG images.
|
|
The image files are named according to network, station, stream and location codes
|
|
of the requested stations. Command\-line parameters override the module configuration.
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scheli capture \-\-stream CX.PB01..HHZ \-\-stream CX.PB02..HHZ \-\-stream CX.PB04..HHZ \-\-interval 10 \-o "/tmp/heli_%N_%S_%L_%C.png" \-H localhost \-I slink://localhost
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
The output file names will be generated based on network code (%N), station code (%S),
|
|
location code (%L) and stream code (%C):
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
/tmp/CX.PB01..HHZ.png
|
|
/tmp/CX.PB02..HHZ.png
|
|
/tmp/CX.PB04..HHZ.png
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SH SETUP
|
|
.sp
|
|
Specifc \fBscheli\fP parameters are adjusted in the \fI\%module configuration\fP\&.
|
|
Colors of traces etc. can be adjusted by setting the \fIscheme\fP parameters in
|
|
the global configuration of scheli. For alternating colors between the traces
|
|
set the parameters scheme.colors.records.foreground and
|
|
scheme.colors.records.alternateForeground in \fBscheli.cfg\fP:
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
# The general color of records/traces.
|
|
scheme.colors.records.foreground = 4286F4
|
|
|
|
# A general trace color of the alternate trace (eg scheli).
|
|
scheme.colors.records.alternateForeground = B72D0E
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SH MODULE CONFIGURATION
|
|
.nf
|
|
\fBetc/defaults/global.cfg\fP
|
|
\fBetc/defaults/scheli.cfg\fP
|
|
\fBetc/global.cfg\fP
|
|
\fBetc/scheli.cfg\fP
|
|
\fB~/.seiscomp/global.cfg\fP
|
|
\fB~/.seiscomp/scheli.cfg\fP
|
|
.fi
|
|
.sp
|
|
.sp
|
|
scheli inherits global options\&.
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.streams
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
List of stream codes to be plotted (net.sta.loc.cha).
|
|
If not in capture mode only the first stream is shown.
|
|
When using a list, the first entry is considered.
|
|
Use commas for separating streams.
|
|
.sp
|
|
Example: GR.MOX..BHZ
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.filter
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Filter to be applied on the data.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.numberOfRows
|
|
Default: \fB48\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Filter to be applied on the data.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.rowTimeSpan
|
|
Default: \fB1800\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
Length of data per trace.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.timeFormat
|
|
Default: \fB%F\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The time format used to print the start and end time of the
|
|
whole plot (upper right corner). The format specification is
|
|
the one used in the strftime function (man strftime).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.recordTime
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Set current time to last data sample.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.lineWidth
|
|
Default: \fB1\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Unit: \fIpx\fP
|
|
.sp
|
|
Line width of traces.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.colors
|
|
Default: \fBFF0000, 0000FF\fP
|
|
.sp
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
A list of alternating row colors cycled through for painting
|
|
traces.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.antialiasing
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Use anti aliasing to plot the traces. The default uses the
|
|
settings from scheme.records.antiAliasing
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.stream.description
|
|
Default: \fBtrue\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Add stream description to traces.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBheli.amplitudeRange.*\fP
|
|
\fIGain\-corrected amplitudes given in units of the sensor.\fP
|
|
\fIFor example: m/s.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.amplitudeRange.scaling
|
|
Default: \fBminmax\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Define the method to scale traces within rows. Possible
|
|
values are:
|
|
.sp
|
|
minmax: Scale all rows to configured minimum and maximum
|
|
amplitudes configured by amplitudeRange.min and
|
|
amplitudeRange.max
|
|
.sp
|
|
row: Scale each row to the maximum within this row.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.amplitudeRange.min
|
|
Default: \fB\-0.00001\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIunit of input data\fP
|
|
.sp
|
|
Minimum amplitude to show in trace. Requires
|
|
amplitudeRange.scale = "minmax".
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.amplitudeRange.max
|
|
Default: \fB0.00001\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIunit of input data\fP
|
|
.sp
|
|
Minimum amplitude to show in trace. Requires
|
|
amplitudeRange.scale = "minmax".
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBheli.dump.*\fP
|
|
\fIControl dumping of PNG images.\fP
|
|
\fIExecute "scheli capture" for image generation in\fP
|
|
\fIthe background without the graphics.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.dump.interval
|
|
Default: \fB\-1\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
Image creation interval. Negative values disable image
|
|
dumping.
|
|
If enabled, images are generated at the configured
|
|
interval.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.dump.outputFile
|
|
Default: \fB/tmp/heli_%N_%S_%L_%C.png\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Name of output file.
|
|
The filename can contain placeholders
|
|
that are replaced by the corresponding streamID parts:
|
|
.sp
|
|
%N : network code
|
|
.sp
|
|
%S : station code
|
|
.sp
|
|
%L : location code
|
|
.sp
|
|
%C : channel code
|
|
.sp
|
|
Placeholders are important if more than one stream
|
|
is given and capture mode is active.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.dump.dpi
|
|
Default: \fB300\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Unit: \fIdpi\fP
|
|
.sp
|
|
Image resolution.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.dump.xres
|
|
Default: \fB1024\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Unit: \fIpx\fP
|
|
.sp
|
|
Number of pixels horizontally.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B heli.dump.yres
|
|
Default: \fB768\fP
|
|
.sp
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Unit: \fIpx\fP
|
|
.sp
|
|
Number of pixels vertically.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B scripts.postprocessing
|
|
Type: \fIpath\fP
|
|
.sp
|
|
Define the path to a script that is called whenever an image
|
|
has been captured and written to disc. The only parameter is
|
|
the path to the generated image.
|
|
.UNINDENT
|
|
.SH COMMAND-LINE OPTIONS
|
|
.sp
|
|
\fBscheli [options]\fP
|
|
.SS Generic
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-h, \-\-help
|
|
Show help message.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-V, \-\-version
|
|
Show version information.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-file arg
|
|
Use alternative configuration file. When this option is
|
|
used the loading of all stages is disabled. Only the
|
|
given configuration file is parsed and used. To use
|
|
another name for the configuration create a symbolic
|
|
link of the application or copy it. Example:
|
|
scautopick \-> scautopick2.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-plugins arg
|
|
Load given plugins.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-D, \-\-daemon
|
|
Run as daemon. This means the application will fork itself
|
|
and doesn\(aqt need to be started with &.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-auto\-shutdown arg
|
|
Enable/disable self\-shutdown because a master module shutdown.
|
|
This only works when messaging is enabled and the master
|
|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
|
for the master module).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-module arg
|
|
Set the name of the master\-module used for auto\-shutdown.
|
|
This is the application name of the module actually
|
|
started. If symlinks are used, then it is the name of
|
|
the symlinked application.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-username arg
|
|
Set the name of the master\-username of the messaging
|
|
used for auto\-shutdown. If "shutdown\-master\-module" is
|
|
given as well, this parameter is ignored.
|
|
.UNINDENT
|
|
.SS Verbosity
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-verbosity arg
|
|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
|
4:debug.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-v, \-\-v
|
|
Increase verbosity level (may be repeated, eg. \-vv).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-q, \-\-quiet
|
|
Quiet mode: no logging output.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-component arg
|
|
Limit the logging to a certain component. This option can
|
|
be given more than once.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-s, \-\-syslog
|
|
Use syslog logging backend. The output usually goes to
|
|
/var/lib/messages.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-l, \-\-lockfile arg
|
|
Path to lock file.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-console arg
|
|
Send log output to stdout.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-debug
|
|
Execute in debug mode.
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-log\-file arg
|
|
Use alternative log file.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-print\-component arg
|
|
For each log entry print the component right after the
|
|
log level. By default the component output is enabled
|
|
for file output but disabled for console output.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-trace
|
|
Execute in trace mode.
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 \-\-print\-component=1
|
|
\-\-print\-context=1 .
|
|
.UNINDENT
|
|
.SS Messaging
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-u, \-\-user arg
|
|
Overrides configuration parameter \fBconnection.username\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-H, \-\-host arg
|
|
Overrides configuration parameter \fBconnection.server\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-t, \-\-timeout arg
|
|
Overrides configuration parameter \fBconnection.timeout\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-g, \-\-primary\-group arg
|
|
Overrides configuration parameter \fBconnection.primaryGroup\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-S, \-\-subscribe\-group arg
|
|
A group to subscribe to.
|
|
This option can be given more than once.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-content\-type arg
|
|
Overrides configuration parameter \fBconnection.contentType\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-start\-stop\-msg arg
|
|
Set sending of a start and a stop message.
|
|
.UNINDENT
|
|
.SS Database
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-db\-driver\-list
|
|
List all supported database drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-d, \-\-database arg
|
|
The database connection string, format:
|
|
\fI\%service://user:pwd@host/database\fP\&.
|
|
"service" is the name of the database driver which
|
|
can be queried with "\-\-db\-driver\-list".
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-module arg
|
|
The config module to use.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-inventory\-db arg
|
|
Load the inventory from the given database or file, format:
|
|
[\fI\%service://]location\fP .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-db arg
|
|
Load the configuration from the given database or file,
|
|
format: [\fI\%service://]location\fP .
|
|
.UNINDENT
|
|
.SS Records
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-driver\-list
|
|
List all supported record stream drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-I, \-\-record\-url arg
|
|
The recordstream source URL, format:
|
|
[\fI\%service://\fP]location[#type].
|
|
"service" is the name of the recordstream driver
|
|
which can be queried with "\-\-record\-driver\-list".
|
|
If "service" is not given, "\fI\%file://\fP" is
|
|
used.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-file arg
|
|
Specify a file as record source.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-type arg
|
|
Specify a type for the records being read.
|
|
.UNINDENT
|
|
.SS User interface
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-F, \-\-full\-screen
|
|
Start the application filling the entire screen.
|
|
This only works with GUI applications.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-N, \-\-non\-interactive
|
|
Use non\-interactive presentation mode. This only works with
|
|
GUI applications.
|
|
.UNINDENT
|
|
.SS Mode
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-offline
|
|
Do not connect to a messaging server and do not use the
|
|
database.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-end\-time arg
|
|
Set the acquisition end time, e.g. \(aq2017\-09\-08 13:30:00\(aq,
|
|
default: \(aqgmt\(aq
|
|
.UNINDENT
|
|
.SS Data
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-stream arg
|
|
The record stream that should be displayed. Can be used
|
|
multiple times for multiple streams.
|
|
.sp
|
|
Example: GR.MOX..BHZ (net.sta.loc.cha)
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-filter arg
|
|
The filter to apply
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-gain arg
|
|
Gain applied to the data before plotting
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-amp\-scaling arg
|
|
Lower bound of amplitude range per row. Possible values:
|
|
.sp
|
|
minmax: Scale all rows to configured minimum and maximum
|
|
amplitudes.
|
|
.sp
|
|
row: Scale each row to the maximum within this row.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-amp\-range\-min arg
|
|
Lower bound of amplitude range per row
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-amp\-range\-max arg
|
|
Upper bound of amplitude range per row
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-amp\-range arg
|
|
Arround zero bound of amplitude range per row
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-time arg
|
|
Do the last row always contain the last record received
|
|
.UNINDENT
|
|
.SS Output
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-desc arg
|
|
Enable/disable the display of a station description
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-rows arg
|
|
Configure the number of rows to display
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-time\-span arg
|
|
Configure the time\-span (in secs) per row. Unit: seconds.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-aa arg
|
|
Set antialiasing for rendering the traces
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-xres arg
|
|
Output x resolution when generating images. Unit: dpi.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-yres arg
|
|
Output y resolution when generating images. Unit: dpi.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-dpi arg
|
|
Output dpi when generating postscript. Unit:dpi.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-o arg
|
|
Output filename. Placeholders are %N,%S,%L,%C for network
|
|
code, station code, location code, channel code.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-interval arg
|
|
Snapshot interval (less than 0 disables timed snapshots).
|
|
Unit: seconds.
|
|
.UNINDENT
|
|
.SH AUTHOR
|
|
gempa GmbH, GFZ Potsdam
|
|
.SH COPYRIGHT
|
|
gempa GmbH, GFZ Potsdam
|
|
.\" Generated by docutils manpage writer.
|
|
.
|