You cannot select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
495 lines
10 KiB
Groff
495 lines
10 KiB
Groff
1 year ago
|
.\" Man page generated from reStructuredText.
|
||
|
.
|
||
|
.TH "SH2PROC" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
|
||
|
.SH NAME
|
||
|
sh2proc \- SeisComP Documentation
|
||
|
.
|
||
|
.nr rst2man-indent-level 0
|
||
|
.
|
||
|
.de1 rstReportMargin
|
||
|
\\$1 \\n[an-margin]
|
||
|
level \\n[rst2man-indent-level]
|
||
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||
|
-
|
||
|
\\n[rst2man-indent0]
|
||
|
\\n[rst2man-indent1]
|
||
|
\\n[rst2man-indent2]
|
||
|
..
|
||
|
.de1 INDENT
|
||
|
.\" .rstReportMargin pre:
|
||
|
. RS \\$1
|
||
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
||
|
. nr rst2man-indent-level +1
|
||
|
.\" .rstReportMargin post:
|
||
|
..
|
||
|
.de UNINDENT
|
||
|
. RE
|
||
|
.\" indent \\n[an-margin]
|
||
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||
|
.nr rst2man-indent-level -1
|
||
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
||
|
..
|
||
|
.sp
|
||
|
\fBConvert SeismicHandler event files to SCML.\fP
|
||
|
.SH DESCRIPTION
|
||
|
.sp
|
||
|
sh2proc converts \fI\%Seismic Handler\fP event data to
|
||
|
SeisComP XML format. Data is read from input file or \fIstdin\fP if no input file is
|
||
|
specified. The result is available on \fIstdout\fP\&.
|
||
|
.SH CODE MAPPING
|
||
|
.sp
|
||
|
Since Seismic Handler only specifies station and component codes, a mapping to
|
||
|
SeisComP network, location and channel codes is necessary. The script assumes
|
||
|
that the same station code is not used in different networks. In case an
|
||
|
ambiguous id is found a warning is printed and the first network code is used.
|
||
|
The channel and stream code is extracted from the dectecStream and detecLocid
|
||
|
configured in the global bindings. In case no configuration module is available
|
||
|
the first location and stream is used.
|
||
|
.SH EVENT PARAMETERS
|
||
|
.INDENT 0.0
|
||
|
.IP \(bu 2
|
||
|
Event types given in Seismic Handler files are mapped to SeisComP event types:
|
||
|
.TS
|
||
|
center;
|
||
|
|l|l|.
|
||
|
_
|
||
|
T{
|
||
|
Seismic Handler
|
||
|
T} T{
|
||
|
SeisComP
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
teleseismic quake
|
||
|
T} T{
|
||
|
earthquake
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
regional quake
|
||
|
T} T{
|
||
|
earthquake
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
local quake
|
||
|
T} T{
|
||
|
earthquake
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
quarry blast
|
||
|
T} T{
|
||
|
quarry blast
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
nuclear explosion
|
||
|
T} T{
|
||
|
nuclear explosion
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
mining event
|
||
|
T} T{
|
||
|
mining explosion
|
||
|
T}
|
||
|
_
|
||
|
.TE
|
||
|
.IP \(bu 2
|
||
|
The EventID given in Seismic Handler files is mapped as a comment to the event.
|
||
|
.UNINDENT
|
||
|
.SH MAGNITUDES
|
||
|
.INDENT 0.0
|
||
|
.IP \(bu 2
|
||
|
Magnitude types given in Seismic Handler files are mapped to SeisComP magnitudes:
|
||
|
.TS
|
||
|
center;
|
||
|
|l|l|.
|
||
|
_
|
||
|
T{
|
||
|
Seismic Handler
|
||
|
T} T{
|
||
|
SeisComP
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
m
|
||
|
T} T{
|
||
|
M
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
ml
|
||
|
T} T{
|
||
|
ML
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
mb
|
||
|
T} T{
|
||
|
mb
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
ms
|
||
|
T} T{
|
||
|
Ms(BB)
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
mw
|
||
|
T} T{
|
||
|
Mw
|
||
|
T}
|
||
|
_
|
||
|
T{
|
||
|
bb
|
||
|
T} T{
|
||
|
mB
|
||
|
T}
|
||
|
_
|
||
|
.TE
|
||
|
.IP \(bu 2
|
||
|
ML magnitudes in Seismic Handler files have no corresponding measured amplitudes.
|
||
|
Therefore the ML station magnitudes are converted without referencing the amplitude.
|
||
|
.IP \(bu 2
|
||
|
Seismic Handler uses the phase name "L" for referring to surface waves without
|
||
|
further specification. The phase name is kept unchanged.
|
||
|
.UNINDENT
|
||
|
.SH DISTANCE CALCULATIONS
|
||
|
.sp
|
||
|
In Seismic Handler files distances can be given in units of km or degree but in
|
||
|
SeisComP only degree is used. Both representations are considered for conversion.
|
||
|
In case of double posting preference is given to the Seismic Handler values given in km
|
||
|
due to their higher precision.
|
||
|
.SH BEAM PARAMETERS
|
||
|
.sp
|
||
|
Seismic Handler files provide the phase picks with theoretical, measured and corrected
|
||
|
slowness and (back) azimuth but the pick in SeisComP knows only one value.
|
||
|
During conversion highest preference is given to corrected values.
|
||
|
The theoretical values are ignored.
|
||
|
.SH LIMITATIONS
|
||
|
.sp
|
||
|
The following parameters from Seismic Handler files are not considered:
|
||
|
.INDENT 0.0
|
||
|
.IP \(bu 2
|
||
|
Phase Flag
|
||
|
.IP \(bu 2
|
||
|
Location Input Params
|
||
|
.IP \(bu 2
|
||
|
Reference Location Name
|
||
|
.IP \(bu 2
|
||
|
Quality Number
|
||
|
.IP \(bu 2
|
||
|
Ampl&Period Source
|
||
|
.IP \(bu 2
|
||
|
Location Quality
|
||
|
.IP \(bu 2
|
||
|
Reference Latitude
|
||
|
.IP \(bu 2
|
||
|
Reference Longitude
|
||
|
.IP \(bu 2
|
||
|
Amplitude Time
|
||
|
.UNINDENT
|
||
|
.SH FURTHER PROCESSING IN SEISCOMP
|
||
|
.sp
|
||
|
The created XML files can be used in multiple ways, e.g.:
|
||
|
.INDENT 0.0
|
||
|
.IP 1. 3
|
||
|
By other modules in an XML\-base playback
|
||
|
.IP 2. 3
|
||
|
Inject into the messaging system by scdispatch
|
||
|
.IP 3. 3
|
||
|
Integrate into the database by scdb
|
||
|
.UNINDENT
|
||
|
.SH EXAMPLES
|
||
|
.INDENT 0.0
|
||
|
.IP 1. 3
|
||
|
Convert the Seismic Handler file \fIshm.evt\fP and writes SC3ML into the file
|
||
|
\fIsc3.xml\fP\&. The database connection to read inventory and configuration
|
||
|
information is fetched from the default messaging connection.
|
||
|
.INDENT 3.0
|
||
|
.INDENT 3.5
|
||
|
.sp
|
||
|
.nf
|
||
|
.ft C
|
||
|
sh2proc shm.evt > sc3.xml
|
||
|
.ft P
|
||
|
.fi
|
||
|
.UNINDENT
|
||
|
.UNINDENT
|
||
|
.IP 2. 3
|
||
|
Read Seismic Handler data from \fIstdin\fP\&. Inventory and configuration information
|
||
|
is provided through files.
|
||
|
.INDENT 3.0
|
||
|
.INDENT 3.5
|
||
|
.sp
|
||
|
.nf
|
||
|
.ft C
|
||
|
cat shm.evt | sh2proc \-\-inventory\-db=inventory.xml \-\-config\-db=config.xml > sc3.xml
|
||
|
.ft P
|
||
|
.fi
|
||
|
.UNINDENT
|
||
|
.UNINDENT
|
||
|
.UNINDENT
|
||
|
.SH SHM.EVT FILE FORMAT
|
||
|
.sp
|
||
|
The list of parameters supported by sh2proc may be incomplete.
|
||
|
Read the original \fI\%format and parameter description\fP
|
||
|
of the SeismicHandler .evt files for providing correct input files.
|
||
|
.sp
|
||
|
Example of a SeismicHandler \fIshm.evt\fP file with supported parameters:
|
||
|
.INDENT 0.0
|
||
|
.INDENT 3.5
|
||
|
.sp
|
||
|
.nf
|
||
|
.ft C
|
||
|
Event ID : 1170102002
|
||
|
Station code : VITZ
|
||
|
Onset time : 2\-JAN\-2017_12:25:40.415
|
||
|
Onset type : emergent
|
||
|
Phase name : Pg
|
||
|
Event Type : mining event
|
||
|
Applied filter : SHM_BP_1HZ_25HZ_3
|
||
|
Component : Z
|
||
|
Quality number : 2
|
||
|
Pick Type : manual
|
||
|
Weight : 4
|
||
|
Theo. Azimuth (deg) : 27.29
|
||
|
Theo. Backazimuth (deg): 207.36
|
||
|
Distance (deg) : 0.122
|
||
|
Distance (km) : 13.572
|
||
|
Magnitude ml : 1.0
|
||
|
Phase Flags : L
|
||
|
\-\-\- End of Phase \-\-\-
|
||
|
|
||
|
|
||
|
Event ID : 1170102002
|
||
|
Station code : WESF
|
||
|
Onset time : 2\-JAN\-2017_12:25:53.714
|
||
|
Onset type : emergent
|
||
|
Phase name : Pg
|
||
|
Event Type : mining event
|
||
|
Applied filter : SHM_BP_1HZ_25HZ_3
|
||
|
Component : Z
|
||
|
Quality number : 2
|
||
|
Pick Type : manual
|
||
|
Weight : 4
|
||
|
Theo. Azimuth (deg) : 106.98
|
||
|
Theo. Backazimuth (deg): 287.91
|
||
|
Distance (deg) : 0.807
|
||
|
Distance (km) : 89.708
|
||
|
Magnitude ml : 1.8
|
||
|
Mean Magnitude ml : 1.1
|
||
|
Latitude : +50.779
|
||
|
Longitude : +10.003
|
||
|
Depth (km) : 0.0
|
||
|
Depth type : (g) estimated
|
||
|
Origin time : 2\-JAN\-2017_12:25:38.273
|
||
|
Region Table : GEO_REG
|
||
|
Region ID : 5326
|
||
|
Source region : Tann, E of Fulda
|
||
|
Velocity Model : deu
|
||
|
Location Input Params : 20
|
||
|
Reference Location Name: CENTRE
|
||
|
\-\-\- End of Phase \-\-\-
|
||
|
.ft P
|
||
|
.fi
|
||
|
.UNINDENT
|
||
|
.UNINDENT
|
||
|
.SH MODULE CONFIGURATION
|
||
|
.nf
|
||
|
\fBetc/defaults/global.cfg\fP
|
||
|
\fBetc/defaults/sh2proc.cfg\fP
|
||
|
\fBetc/global.cfg\fP
|
||
|
\fBetc/sh2proc.cfg\fP
|
||
|
\fB~/.seiscomp/global.cfg\fP
|
||
|
\fB~/.seiscomp/sh2proc.cfg\fP
|
||
|
.fi
|
||
|
.sp
|
||
|
.sp
|
||
|
sh2proc inherits global options\&.
|
||
|
.SH COMMAND-LINE OPTIONS
|
||
|
.sp
|
||
|
\fBsh2proc [options]\fP
|
||
|
.SS Generic
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-h, \-\-help
|
||
|
Show help message.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-V, \-\-version
|
||
|
Show version information.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-config\-file arg
|
||
|
Use alternative configuration file. When this option is
|
||
|
used the loading of all stages is disabled. Only the
|
||
|
given configuration file is parsed and used. To use
|
||
|
another name for the configuration create a symbolic
|
||
|
link of the application or copy it. Example:
|
||
|
scautopick \-> scautopick2.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-plugins arg
|
||
|
Load given plugins.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-D, \-\-daemon
|
||
|
Run as daemon. This means the application will fork itself
|
||
|
and doesn\(aqt need to be started with &.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-auto\-shutdown arg
|
||
|
Enable/disable self\-shutdown because a master module shutdown.
|
||
|
This only works when messaging is enabled and the master
|
||
|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
||
|
for the master module).
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-shutdown\-master\-module arg
|
||
|
Set the name of the master\-module used for auto\-shutdown.
|
||
|
This is the application name of the module actually
|
||
|
started. If symlinks are used, then it is the name of
|
||
|
the symlinked application.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-shutdown\-master\-username arg
|
||
|
Set the name of the master\-username of the messaging
|
||
|
used for auto\-shutdown. If "shutdown\-master\-module" is
|
||
|
given as well, this parameter is ignored.
|
||
|
.UNINDENT
|
||
|
.SS Verbosity
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-verbosity arg
|
||
|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
||
|
4:debug.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-v, \-\-v
|
||
|
Increase verbosity level (may be repeated, eg. \-vv).
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-q, \-\-quiet
|
||
|
Quiet mode: no logging output.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-component arg
|
||
|
Limit the logging to a certain component. This option can
|
||
|
be given more than once.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-s, \-\-syslog
|
||
|
Use syslog logging backend. The output usually goes to
|
||
|
/var/lib/messages.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-l, \-\-lockfile arg
|
||
|
Path to lock file.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-console arg
|
||
|
Send log output to stdout.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-debug
|
||
|
Execute in debug mode.
|
||
|
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-log\-file arg
|
||
|
Use alternative log file.
|
||
|
.UNINDENT
|
||
|
.SS Messaging
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-u, \-\-user arg
|
||
|
Overrides configuration parameter \fBconnection.username\fP\&.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-H, \-\-host arg
|
||
|
Overrides configuration parameter \fBconnection.server\fP\&.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-t, \-\-timeout arg
|
||
|
Overrides configuration parameter \fBconnection.timeout\fP\&.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-g, \-\-primary\-group arg
|
||
|
Overrides configuration parameter \fBconnection.primaryGroup\fP\&.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-S, \-\-subscribe\-group arg
|
||
|
A group to subscribe to.
|
||
|
This option can be given more than once.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-content\-type arg
|
||
|
Overrides configuration parameter \fBconnection.contentType\fP\&.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-start\-stop\-msg arg
|
||
|
Set sending of a start and a stop message.
|
||
|
.UNINDENT
|
||
|
.SS Database
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-db\-driver\-list
|
||
|
List all supported database drivers.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-d, \-\-database arg
|
||
|
The database connection string, format:
|
||
|
\fI\%service://user:pwd@host/database\fP\&.
|
||
|
"service" is the name of the database driver which
|
||
|
can be queried with "\-\-db\-driver\-list".
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-config\-module arg
|
||
|
The config module to use.
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-inventory\-db arg
|
||
|
Load the inventory from the given database or file, format:
|
||
|
[\fI\%service://]location\fP .
|
||
|
.UNINDENT
|
||
|
.INDENT 0.0
|
||
|
.TP
|
||
|
.B \-\-db\-disable
|
||
|
Do not use the database at all
|
||
|
.UNINDENT
|
||
|
.SH AUTHOR
|
||
|
gempa GmbH, GFZ Potsdam
|
||
|
.SH COPYRIGHT
|
||
|
gempa GmbH, GFZ Potsdam
|
||
|
.\" Generated by docutils manpage writer.
|
||
|
.
|