You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

279 lines
6.0 KiB
Groff

.\" Man page generated from reStructuredText.
.
.TH "IMPORT_INV" "1" "Jan 10, 2023" "5.3.0" "SeisComP"
.SH NAME
import_inv \- SeisComP Documentation
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.sp
\fBImport inventory information from various sources.\fP
.SH DESCRIPTION
.sp
import_inv is a wrapper for inventory converters. Inventory converters convert
an input format such as
.TS
center;
|l|l|l|.
_
T{
Format
T} T{
Converter
T} T{
Conversion
T}
_
T{
scml
T} T{
scml2inv
T} T{
SeisComP inventory XML, schema: \fB$SEISCOMP_ROOT/share/xml/\fP
T}
_
T{
sc3
T} T{
sc32inv
T} T{
Alias for scml for backwards compatibility to SeisComP3
T}
_
T{
arclink
T} T{
arclink2inv
T} T{
Arclink inventory XML
T}
_
T{
dlsv
T} T{
dlsv2inv
T} T{
\fI\%dataless SEED\fP
T}
_
T{
fdsnxml
T} T{
fdsnxml2inv
T} T{
\fI\%FDSN StationXML\fP
T}
_
.TE
.sp
to SeisComP inventory XML which is read by the trunk config module to
synchronize the local inventory file pool with the central inventory database.
.sp
For printing all available formats call
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
$ import_inv help formats
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
When \fBimport_inv help formats\fP is called it globs for
\fB$SEISCOMP_ROOT/bin/*2inv\fP\&.
If another format needs to be converted, it is very easy to provide a new
converter.
.SS Converter interface
.sp
For making a new converter work with import_inv it must implement an interface
on shell level. Furthermore the converter program must be named
\fB\fIformat\fP\fP\fB2inv\fP and must live in \fBSEISCOMP_ROOT/bin\fP\&.
.sp
The converter program must take the input location (file, directory, URL, ...)
as first parameter and the output file (SeisComP XML) as second parameter. The
output file must be optional and default to stdout.
.sp
To add a new converter for a new format, e.g. Excel, place the new converter
program at \fB$SEISCOMP_ROOT/bin/excel2inv\fP\&.
.SS Examples
.INDENT 0.0
.IP \(bu 2
Convert inventory file in FDSN StationXML format (fdsnxml) and copy the content to
\fB$SEISCOMP_ROOT/etc/inventoy/inventory.xml\fP\&. The call will invoke
fdsnxml2inv for actually making the conversion:
.INDENT 2.0
.INDENT 3.5
.sp
.nf
.ft C
$ import_inv fdsnxml inventory_fdsn.xml $SEISCOMP_ROOT/etc/inventoy/inventory.xml
.ft P
.fi
.UNINDENT
.UNINDENT
.UNINDENT
.SH MODULE CONFIGURATION
.nf
\fBetc/defaults/global.cfg\fP
\fBetc/defaults/import_inv.cfg\fP
\fBetc/global.cfg\fP
\fBetc/import_inv.cfg\fP
\fB~/.seiscomp/global.cfg\fP
\fB~/.seiscomp/import_inv.cfg\fP
.fi
.sp
.sp
import_inv inherits global options\&.
.SH COMMAND-LINE OPTIONS
.sp
\fBimport_inv [FORMAT] input [output]\fP
.sp
\fBimport_inv help [topic]\fP
.sp
The first form takes the format as first parameter and the input
and output location. The input location is either a file or directory
depending on the format and its converter. If the output is not
given it defaults to seiscomp/etc/inventory/{input}.xml. To write
the output to stdout, "\-" must be used.
.sp
The second form provides help on a particular topic. The only topic
currently supported is "formats" which prints all available input
formats.
.SS Generic
.INDENT 0.0
.TP
.B \-h, \-\-help
Show help message.
.UNINDENT
.INDENT 0.0
.TP
.B \-V, \-\-version
Show version information.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-file arg
Use alternative configuration file. When this option is
used the loading of all stages is disabled. Only the
given configuration file is parsed and used. To use
another name for the configuration create a symbolic
link of the application or copy it. Example:
scautopick \-> scautopick2.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-plugins arg
Load given plugins.
.UNINDENT
.INDENT 0.0
.TP
.B \-D, \-\-daemon
Run as daemon. This means the application will fork itself
and doesn\(aqt need to be started with &.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-auto\-shutdown arg
Enable/disable self\-shutdown because a master module shutdown.
This only works when messaging is enabled and the master
module sends a shutdown message (enabled with \-\-start\-stop\-msg
for the master module).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-module arg
Set the name of the master\-module used for auto\-shutdown.
This is the application name of the module actually
started. If symlinks are used, then it is the name of
the symlinked application.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-username arg
Set the name of the master\-username of the messaging
used for auto\-shutdown. If "shutdown\-master\-module" is
given as well, this parameter is ignored.
.UNINDENT
.SS Verbosity
.INDENT 0.0
.TP
.B \-\-verbosity arg
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
4:debug.
.UNINDENT
.INDENT 0.0
.TP
.B \-v, \-\-v
Increase verbosity level (may be repeated, eg. \-vv).
.UNINDENT
.INDENT 0.0
.TP
.B \-q, \-\-quiet
Quiet mode: no logging output.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-component arg
Limit the logging to a certain component. This option can
be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-s, \-\-syslog
Use syslog logging backend. The output usually goes to
/var/lib/messages.
.UNINDENT
.INDENT 0.0
.TP
.B \-l, \-\-lockfile arg
Path to lock file.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-console arg
Send log output to stdout.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-debug
Execute in debug mode.
Equivalent to \-\-verbosity=4 \-\-console=1 .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-log\-file arg
Use alternative log file.
.UNINDENT
.SH AUTHOR
gempa GmbH, GFZ Potsdam
.SH COPYRIGHT
gempa GmbH, GFZ Potsdam
.\" Generated by docutils manpage writer.
.