You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

309 lines
7.0 KiB
Plaintext

.. highlight:: rst
.. _scbulletin:
##########
scbulletin
##########
**Create bulletins from SCML.**
Description
===========
scbulletin transforms the parameters of an event or an origin either to autoloc1
or to autoloc3 format.
Input Modes
-----------
Two modes of parameter input are possible:
1. Either one can fetch all necessary information from database directly
#. or one can provide a representation of the origin as XML file, to transform it
to a standard format.
The first mode is the dump-mode the second is the input-mode. For dumping either
choose eventID or the originID. If the eventID is choosen the preferred origin
will be used.
Output Modes
------------
Different output formats are available by command-line options:
#. ``-1`` for **autoloc1**: Print one bulletin per event.
#. ``-3`` for **autoloc3**: Print one bulletin per event.
#. ``--fdsnws`` for FDSNWS event text: Print one line per event. Useful for
generating event catalogs. This option offers an alternative to generating
event catalogs by :ref:`fdsnws-event <sec-event>`.
#. ``-3 -x`` for **extended autoloc3**.
#. ``-1 -e`` or ``-3 -e`` for **enhanced** output at high-precision. All times
and distances are in units of milliseconds and meters, respectively.
If called with an event or origin ID, a database connection is necessary to
fetch the corresponding object. Otherwise scbulletin will read the input source
(defaults to stdin), grab the found events or origins and dump the bulletins.
The input can be filtered by the event or origin IDs. Event and origin IDs can
be provided by :ref:`scevtls` and :ref:`scorgls`, respectively.
Examples
========
#. Create a bulletin from one or multiple event(s) in database
.. code-block:: sh
scbulletin -d mysql://sysop:sysop@localhost/seiscomp -E gfz2012abcd
scbulletin -d mysql://sysop:sysop@localhost/seiscomp -E gfz2012abcd,gfz2022abcd
#. Convert XML file to bulletin
.. code-block:: sh
scbulletin < gfz2012abcd.xml
.. code-block:: sh
scbulletin -i gfz2012abcd.xml
#. Convert XML file to bulletin but filter by event ID(s)
.. code-block:: sh
scbulletin -i gfz2012abcd.xml -E gempa2022abcd
scbulletin -i gfz2012abcd.xml -E gempa2022abcd,gfz2022abcd
.. note::
When considering a single event XML file containing many events, the
bulletins of all events will be generated unless ``--first-only`` is used.
.. _scbulletin_configuration:
Module Configuration
====================
| :file:`etc/defaults/global.cfg`
| :file:`etc/defaults/scbulletin.cfg`
| :file:`etc/global.cfg`
| :file:`etc/scbulletin.cfg`
| :file:`~/.seiscomp/global.cfg`
| :file:`~/.seiscomp/scbulletin.cfg`
scbulletin inherits :ref:`global options<global-configuration>`.
Command-Line Options
====================
.. program:: scbulletin
:program:`scbulletin [options]`
Generic
-------
.. option:: -h, --help
Show help message.
.. option:: -V, --version
Show version information.
.. option:: --config-file arg
Use alternative configuration file. When this option is
used the loading of all stages is disabled. Only the
given configuration file is parsed and used. To use
another name for the configuration create a symbolic
link of the application or copy it. Example:
scautopick \-> scautopick2.
.. option:: --plugins arg
Load given plugins.
.. option:: -D, --daemon
Run as daemon. This means the application will fork itself
and doesn't need to be started with \&.
.. option:: --auto-shutdown arg
Enable\/disable self\-shutdown because a master module shutdown.
This only works when messaging is enabled and the master
module sends a shutdown message \(enabled with \-\-start\-stop\-msg
for the master module\).
.. option:: --shutdown-master-module arg
Set the name of the master\-module used for auto\-shutdown.
This is the application name of the module actually
started. If symlinks are used, then it is the name of
the symlinked application.
.. option:: --shutdown-master-username arg
Set the name of the master\-username of the messaging
used for auto\-shutdown. If \"shutdown\-master\-module\" is
given as well, this parameter is ignored.
Verbosity
---------
.. option:: --verbosity arg
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
4:debug.
.. option:: -v, --v
Increase verbosity level \(may be repeated, eg. \-vv\).
.. option:: -q, --quiet
Quiet mode: no logging output.
.. option:: --component arg
Limit the logging to a certain component. This option can
be given more than once.
.. option:: -s, --syslog
Use syslog logging backend. The output usually goes to
\/var\/lib\/messages.
.. option:: -l, --lockfile arg
Path to lock file.
.. option:: --console arg
Send log output to stdout.
.. option:: --debug
Execute in debug mode.
Equivalent to \-\-verbosity\=4 \-\-console\=1 .
.. option:: --log-file arg
Use alternative log file.
Database
--------
.. option:: --db-driver-list
List all supported database drivers.
.. option:: -d, --database arg
The database connection string, format:
service:\/\/user:pwd\@host\/database.
\"service\" is the name of the database driver which
can be queried with \"\-\-db\-driver\-list\".
.. option:: --config-module arg
The config module to use.
.. option:: --inventory-db arg
Load the inventory from the given database or file, format:
[service:\/\/]location .
.. option:: --db-disable
Do not use the database at all
Input
-----
.. option:: -f, --format arg
Input format to use \(xml [default], zxml \(zipped xml\), binary\).
.. option:: -i, --input arg
The input file. Default is stdin.
Dump
----
.. option:: -E, --event arg
ID of event that is read from database and transformed into
a bulletin. Separate multiple IDs by comma.\"
.. option:: -O, --origin arg
ID of origin that is read from database and transformed into
a bulletin. Separate multiple IDs by comma.
.. option:: -1, --autoloc1
Use autoloc1 format for output. This is default.
.. option:: -3, --autoloc3
Use autoloc3 format for output.
.. option:: -x, --extra
Use a specially detailed autoloc3 format. This options works
only in combination with the autoloc3\-flag.
.. option:: -e, --enhanced
Enhanced output with higher precision. Times: milliseconds,
distances: meter. Use for bulletins of local earthquakes.
.. option:: --event-agency-id
Use the agency ID of the event instead of the preferred origin.
.. option:: --fdsnws
Dump in FDSNWS event text format, e.g., for generating catalogs.
.. option:: --first-only
Convert only the first event\/origin to bulletin. Otherwise
all events or origins will be converted to single bulletins
which will be concatenated.
.. option:: -k, --dist-in-km
Plot distances in km instead of degree.
.. option:: -p, --polarities
Dump onset polarities.
.. option:: -w, --weight arg
Weight threshold for printed and counted picks.
.. option:: -x, --extra
Use a specially detailed autoloc3 format. This options works only
in combination with the autoloc3\-flag.