You cannot select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
88 lines
2.7 KiB
INI
88 lines
2.7 KiB
INI
2 years ago
|
# Send to the PICK group
|
||
|
connection.primaryGroup = PICK
|
||
|
|
||
|
# Send amplitudes to this group
|
||
|
connection.amplitudeGroup = AMPLITUDE
|
||
|
|
||
|
# Receive objects from CONFIG group
|
||
|
connection.subscriptions = CONFIG
|
||
|
|
||
|
# The filter used to trigger
|
||
|
filter = "RMHP(10)>>ITAPER(30)>>BW(4,0.7,2)>>STALTA(2,80)"
|
||
|
|
||
|
# The time correction applied to a detected pick
|
||
|
timeCorrection = -0.8
|
||
|
|
||
|
# The record ringbuffer size in seconds
|
||
|
ringBufferSize = 300
|
||
|
|
||
|
# The leadTime defines the time in seconds to
|
||
|
# start picking on the streams before current
|
||
|
# time
|
||
|
leadTime = 60
|
||
|
|
||
|
# The initTime defines a timespan in seconds
|
||
|
# for that the picker is blind after initialization
|
||
|
# This time is needed to initialize the filter and
|
||
|
# depends on it
|
||
|
initTime = 60
|
||
|
|
||
|
# Interpolate gaps linearly? This is valid for gaps
|
||
|
# short than thresholds.maxGapLength
|
||
|
gapInterpolation = false
|
||
|
|
||
|
# For which value on a filtered stream is
|
||
|
# a pick detected
|
||
|
thresholds.triggerOn = 3
|
||
|
|
||
|
# The value the filtered stream must reach to
|
||
|
# enable detection again
|
||
|
thresholds.triggerOff = 1.5
|
||
|
|
||
|
# The maximum gap length to handle. Gaps larger
|
||
|
# than this size reset the picker
|
||
|
thresholds.maxGapLength = 4.5
|
||
|
|
||
|
# The timeWindow used to compute a maximum (snr)
|
||
|
# amplitude on the filtered stream
|
||
|
thresholds.amplMaxTimeWindow = 10
|
||
|
|
||
|
thresholds.deadTime = 30
|
||
|
thresholds.minAmplOffset = 3
|
||
|
|
||
|
# The amplitudes to compute triggered by
|
||
|
# a new P Pick continuously without having
|
||
|
# an Origin
|
||
|
amplitudes = MLv, mb, mB
|
||
|
|
||
|
# Configures the picker to use. By default only simple
|
||
|
# STALTA detections are emitted as picks. To enable "repicking"
|
||
|
# define a picker algorithm here.
|
||
|
picker = ""
|
||
|
|
||
|
# Configures the secondary picker to be used.
|
||
|
spicker = ""
|
||
|
|
||
|
# Configures the feature extraction type to be used
|
||
|
fx = ""
|
||
|
|
||
|
# If enabled the all streams are used for picking that are received by the
|
||
|
# picker. This option has only effect if a file is used as input which contains
|
||
|
# more data than the picker requests or if amplitudes are enabled which are using
|
||
|
# the horizontal components.
|
||
|
useAllStreams = false
|
||
|
|
||
|
# If enabled the all secondary pickers that were triggered by a previous pick
|
||
|
# will be terminated when a new detection or pick has been found. This aims to
|
||
|
# avoid the case where an S phase is wrongly picked as P but would also be
|
||
|
# picked as S by the secondary picker. But suppressing the S pick can lead to
|
||
|
# undesired results. It might be better in some situations to have two picks
|
||
|
# (P and S) instead only a wrong P.
|
||
|
killPendingSPickers = true
|
||
|
|
||
|
# If enabled and a picker is configured then detections are sent as well.
|
||
|
# To distinguish between detections and picks the evaluation mode of the pick
|
||
|
# is set to manual. This is meant to be a debug option which can be used to
|
||
|
# compare detections and picks by their evaluation mode.
|
||
|
sendDetections = false
|