Files
2025/share/man/man1/scevtstreams.1

410 lines
9.2 KiB
Groff

.\" Man page generated from reStructuredText.
.
.
.nr rst2man-indent-level 0
.
.de1 rstReportMargin
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.de1 INDENT
.\" .rstReportMargin pre:
. RS \\$1
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
. nr rst2man-indent-level +1
.\" .rstReportMargin post:
..
.de UNINDENT
. RE
.\" indent \\n[an-margin]
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
..
.TH "SCEVTSTREAMS" "1" "Oct 29, 2025" "7.0.0" "SeisComP"
.SH NAME
scevtstreams \- SeisComP Documentation
.sp
\fBExtract stream information and time windows from picks of an event or
solitary picks.\fP
.SH DESCRIPTION
.sp
scevtstreams reads all picks of an event or solitary picks determining the time
window between the first pick and the last pick.
In addition symmetric asymmetric time margins are added to this time window.
It writes the streams that are picked including the determined
time window for the event to stdout. This tool gives appropriate input
information for \fI\%scart\fP, \fI\%fdsnws\fP and \fIcapstool\fP [\fI\%30\fP] for
\fICAPS\fP [\fI\%3\fP] server (Common Acquisition Protocol Server by gempa GmbH) to dump
waveforms from archives based on event data.
.sp
Events with origins and picks can be read from database or XML file. Solitary
picks can only be read from XML file. The XML files can be generated using
\fI\%scxmldump\fP\&.
.SH OUTPUT FORMAT
.sp
The generated list contains start and end time as well as stream information.
.sp
Generic:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
starttime;endtime;stream
.ft P
.fi
.UNINDENT
.UNINDENT
.sp
Example:
.INDENT 0.0
.INDENT 3.5
.sp
.nf
.ft C
2019\-07\-17 02:00:00;2019\-07\-17 02:10:00;GR.CLL..BHZ
.ft P
.fi
.UNINDENT
.UNINDENT
.SH EXAMPLES
.INDENT 0.0
.IP 1. 3
Get the time windows for an event in the database:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-E gfz2012abcd \-d mysql://sysop:sysop@localhost/seiscomp
.ft P
.fi
.UNINDENT
.UNINDENT
.IP 2. 3
Get the time windows for one specific event or all events in a XML file.
The time windows start 120 s before the first pick and ends 500 s after the
last pick:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-i event.xml \-E gfz2012abcd
scevtstreams \-i event.xml
.ft P
.fi
.UNINDENT
.UNINDENT
.IP 3. 3
Get the time windows from all picks in a XML file which does not contain
events or origins:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-i picks.xml
.ft P
.fi
.UNINDENT
.UNINDENT
.IP 4. 3
Combine with \fI\%scart\fP for creating a \fI\%miniSEED\fP data file from one
event. The time window starts and ends 5 minutes before the first and after
the last pick, respectively.
The data is read from \fI\%SDS\fP archive and sorted by end time:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-E gfz2012abcd \-d mysql://sysop:sysop@localhost/seiscomp \-m 300 |\e
scart \-dsvE \-\-list \- ~/seiscomp/acquisition/archive > gfz2012abcd\-sorted.mseed
.ft P
.fi
.UNINDENT
.UNINDENT
.IP 5. 3
Download waveforms from FDSN and import into local archive. Include
all stations from the contributing networks:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-E gfz2012abcd \-d mysql://sysop:sysop@localhost/seiscomp \-m 300 \-R \-\-all\-stations |\e
scart \-\-list \- \-I fdsnws://geofon.gfz.de ./my\-archive
.ft P
.fi
.UNINDENT
.UNINDENT
.IP 6. 3
Create lists compatible with \fI\%fdsnws\fP POST format or \fIcapstool\fP [\fI\%30\fP]:
.INDENT 3.0
.INDENT 3.5
.sp
.nf
.ft C
scevtstreams \-E gfz2012abcd \-i event.xml \-m 120,500 \-\-fdsnws
scevtstreams \-E gfz2012abcd \-i event.xml \-m 120,500 \-\-caps
.ft P
.fi
.UNINDENT
.UNINDENT
.UNINDENT
.SH MODULE CONFIGURATION
.nf
\fBetc/defaults/global.cfg\fP
\fBetc/defaults/scevtstreams.cfg\fP
\fBetc/global.cfg\fP
\fBetc/scevtstreams.cfg\fP
\fB~/.seiscomp/global.cfg\fP
\fB~/.seiscomp/scevtstreams.cfg\fP
.fi
.sp
.sp
scevtstreams inherits \fI\%global options\fP\&.
.SH COMMAND-LINE OPTIONS
.sp
\fBscevtstreams [options]\fP
.SS Generic
.INDENT 0.0
.TP
.B \-h, \-\-help
Show help message.
.UNINDENT
.INDENT 0.0
.TP
.B \-V, \-\-version
Show version information.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-file arg
Use alternative configuration file. When this option is
used the loading of all stages is disabled. Only the
given configuration file is parsed and used. To use
another name for the configuration create a symbolic
link of the application or copy it. Example:
scautopick \-> scautopick2.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-plugins arg
Load given plugins.
.UNINDENT
.INDENT 0.0
.TP
.B \-D, \-\-daemon
Run as daemon. This means the application will fork itself
and doesn\(aqt need to be started with &.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-auto\-shutdown arg
Enable/disable self\-shutdown because a master module shutdown.
This only works when messaging is enabled and the master
module sends a shutdown message (enabled with \-\-start\-stop\-msg
for the master module).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-module arg
Set the name of the master\-module used for auto\-shutdown.
This is the application name of the module actually
started. If symlinks are used, then it is the name of
the symlinked application.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-shutdown\-master\-username arg
Set the name of the master\-username of the messaging
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
given as well, this parameter is ignored.
.UNINDENT
.SS Verbosity
.INDENT 0.0
.TP
.B \-\-verbosity arg
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
4:debug.
.UNINDENT
.INDENT 0.0
.TP
.B \-v, \-\-v
Increase verbosity level (may be repeated, eg. \-vv).
.UNINDENT
.INDENT 0.0
.TP
.B \-q, \-\-quiet
Quiet mode: no logging output.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-component arg
Limit the logging to a certain component. This option can
be given more than once.
.UNINDENT
.INDENT 0.0
.TP
.B \-s, \-\-syslog
Use syslog logging backend. The output usually goes to
/var/lib/messages.
.UNINDENT
.INDENT 0.0
.TP
.B \-l, \-\-lockfile arg
Path to lock file.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-console arg
Send log output to stdout.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-debug
Execute in debug mode.
Equivalent to \-\-verbosity=4 \-\-console=1 .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-log\-file arg
Use alternative log file.
.UNINDENT
.SS Database
.INDENT 0.0
.TP
.B \-\-db\-driver\-list
List all supported database drivers.
.UNINDENT
.INDENT 0.0
.TP
.B \-d, \-\-database arg
The database connection string, format:
\fI\%service://user:pwd@host/database\fP\&.
\(dqservice\(dq is the name of the database driver which
can be queried with \(dq\-\-db\-driver\-list\(dq.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-config\-module arg
The config module to use.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-inventory\-db arg
Load the inventory from the given database or file, format:
[\fI\%service://]location\fP .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-db\-disable
Do not use the database at all
.UNINDENT
.SS Input
.INDENT 0.0
.TP
.B \-i, \-\-input arg
Input XML file name. Reads event and picks from the XML file
instead of database. Use \(aq\-\(aq to read from stdin.
.UNINDENT
.INDENT 0.0
.TP
.B \-f, \-\-format arg
Input format to use (xml [default], zxml (zipped xml),
binary). Only relevant with \-i.
.UNINDENT
.SS Dump
.INDENT 0.0
.TP
.B \-E, \-\-event arg
The ID of the event to consider.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-net\-sta arg
Filter read picks by network code or network and station
code. Format: NET or NET.STA .
.UNINDENT
.INDENT 0.0
.TP
.B \-\-nslc arg
Stream list file to be used for filtering read picks by
stream code. \(aq\-\-net\-sta\(aq will be ignored. One line per
stream. Line format: NET.STA.LOC.CHA.
.UNINDENT
.SS Output
.INDENT 0.0
.TP
.B \-m, \-\-margin arg
Time margin around the picked time window, default is 300.
Added before the first and after the last pick,
respectively. Use 2 comma\-separted values (before,after)
for asymmetric margins. Example: 120,300.
.UNINDENT
.INDENT 0.0
.TP
.B \-S, \-\-streams arg
Comma separated list of streams per station to add.
Example: BH,SH,HH.
.UNINDENT
.INDENT 0.0
.TP
.B \-C, \-\-all\-components arg
Specify whether to use all components (1) or just the
picked ones (0). Default: 1.
.UNINDENT
.INDENT 0.0
.TP
.B \-L, \-\-all\-locations arg
Specify whether to use all location codes (1) or just
the picked ones (0). Default: 1.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-all\-stations
Dump all stations from the same network. If unused, just
stations with picks are dumped.
.UNINDENT
.INDENT 0.0
.TP
.B \-\-all\-networks
Dump all networks. If unused, just networks with picks are
dumped. This option implies \-\-all\-stations, \-\-all\-locations,
\-\-all\-streams, \-\-all\-components and will only provide the
time window.
.UNINDENT
.INDENT 0.0
.TP
.B \-R, \-\-resolve\-wildcards flag
If all components are used, use inventory to resolve stream
components instead of using \(aq?\(aq (important when Arclink
should be used).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-caps
Dump in capstool format (Common Acquisition Protocol Server
by gempa GmbH).
.UNINDENT
.INDENT 0.0
.TP
.B \-\-fdsnws flag
Dump in FDSN dataselect webservice POST format.
.UNINDENT
.SH AUTHOR
gempa GmbH, GFZ Potsdam
.SH COPYRIGHT
gempa GmbH, GFZ Potsdam
.\" Generated by docutils manpage writer.
.