1946 lines
43 KiB
Groff
1946 lines
43 KiB
Groff
.\" Man page generated from reStructuredText.
|
|
.
|
|
.
|
|
.nr rst2man-indent-level 0
|
|
.
|
|
.de1 rstReportMargin
|
|
\\$1 \\n[an-margin]
|
|
level \\n[rst2man-indent-level]
|
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
-
|
|
\\n[rst2man-indent0]
|
|
\\n[rst2man-indent1]
|
|
\\n[rst2man-indent2]
|
|
..
|
|
.de1 INDENT
|
|
.\" .rstReportMargin pre:
|
|
. RS \\$1
|
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
|
. nr rst2man-indent-level +1
|
|
.\" .rstReportMargin post:
|
|
..
|
|
.de UNINDENT
|
|
. RE
|
|
.\" indent \\n[an-margin]
|
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.nr rst2man-indent-level -1
|
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
|
..
|
|
.TH "SCRTTV" "1" "Sep 22, 2025" "6.9.0" "SeisComP"
|
|
.SH NAME
|
|
scrttv \- SeisComP Documentation
|
|
.sp
|
|
\fBReal\-time trace view.\fP
|
|
.SH DESCRIPTION
|
|
.sp
|
|
scrttv visualizes waveform data in miniSEED format
|
|
(see \fI\%Figure below\fP) in real\-time or from archives
|
|
with a defined window length (default: 30 minutes) of defined streams/stations
|
|
(default: streams defined by global bindings). Additionally, phase picks are
|
|
visualized.
|
|
.sp
|
|
scrttv can be used for view waveforms,
|
|
\fI\%visual waveform quality control\fP or
|
|
\fI\%interactive signal detection\fP\&.
|
|
.sp
|
|
When in message mode scrttv dynamically resorts waveforms:
|
|
Normally, the trace order is given by configuration, e.g., ordering by epicentral
|
|
distance from a location given by \fI\%streams.sort.latitude\fP and
|
|
\fI\%streams.sort.longitude\fP\&.
|
|
In the event that a new SeisComP \fI\%event\fP arrives from the messaging, the
|
|
traces are sorted automatically by epicentral distance to the latest origin
|
|
received. In addition to waveforms, information about gaps or overlaps, picks
|
|
and the time of incoming origins are displayed.
|
|
.INDENT 0.0
|
|
.INDENT 2.5
|
|
[image]
|
|
scrttv overview
|
|
An example of scrttv and the dialog window to associate picks to new origins.
|
|
Tabs: Enable/Disable; Amplitude: mean and maximum;
|
|
Stream: station, network, sensor location and channel code;
|
|
Filter: filter applied traces; Status = connection status to messaging.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
scrttv shows two tabs: the Enabled and the disabled tab
|
|
(see \fI\%scrttv overview\fP). Stations listed in the disabled tab
|
|
are excluded from automatic processing (e.g. phase picking). To move a station
|
|
from one tab to another just drag and drop the trace to the new tab. An alternative solution is
|
|
to double click on the trace label to disable a trace. Read the section
|
|
\fI\%Waveform Quality Control\fP for the details.
|
|
.sp
|
|
Normally, the raw data are displayed. Pressing \fBf\fP the predefined bandpass filter
|
|
of third order from 0.5 Hz to 8 Hz, \fI\%BW(3,0.5,8)\fP is applied
|
|
to the traces. Also zoom functions for the time and amplitude axis are provided.
|
|
Read the sections <scrttv\-filtering> and \fI\%Waveform Visualization\fP for
|
|
more details.
|
|
.sp
|
|
Among the configurable parameters are:
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
Global \fI\%bindings\fP:
|
|
.INDENT 2.0
|
|
.IP \(bu 2
|
|
default definition of traces to show (\fI\%detecStream\fP and \fI\%detecLocid\fP).
|
|
.UNINDENT
|
|
.IP \(bu 2
|
|
\fI\%Module\fP configuration:
|
|
.INDENT 2.0
|
|
.IP \(bu 2
|
|
network, stations, locations and streams to show extending or overriding the
|
|
default definition (\fI\%streams.codes\fP),
|
|
.IP \(bu 2
|
|
\fI\%data filters\fP,
|
|
.IP \(bu 2
|
|
buffer size controlling the length of loaded data (\fI\%bufferSize\fP),
|
|
.IP \(bu 2
|
|
sorting of traces upon arrival of new origins (\fI\%resortAutomatically\fP),
|
|
.IP \(bu 2
|
|
reference coordinate for sorting traces by default (\fBstreams.sort.*\fP),
|
|
.IP \(bu 2
|
|
region filters (\fBstreams.region.*\fP),
|
|
.IP \(bu 2
|
|
\fI\%grouping of streams\fP with different properties,
|
|
.IP \(bu 2
|
|
number of traces to show with fixed height (\fI\%streams.rows\fP).
|
|
.UNINDENT
|
|
.IP \(bu 2
|
|
Scheme parameters in global \fI\%module\fP configuration:
|
|
.INDENT 2.0
|
|
.IP \(bu 2
|
|
trace properties and trace background colors,
|
|
.IP \(bu 2
|
|
font and general GUI parameters.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
More parameters are available on the command\-line:
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scrttv \-h
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SH MODES OF OPERATION
|
|
.sp
|
|
scrttv can be started in message mode or in offline mode.
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
Message mode: scrttv is started normally and connects to the messaging,
|
|
picks, \fI\%origins\fP and inventory are read from
|
|
the database and received in real time from the messaging. Data are received
|
|
from \fI\%recordstream\fP\&.
|
|
.IP \(bu 2
|
|
Offline mode: scrttv is started without connection to the messaging,
|
|
picks and \fI\%origins\fP are not received in real
|
|
time from the messaging. However, they can be loaded from XML files using the
|
|
\fIFile\fP menu. Data are received from \fI\%recordstream\fP or from file. The
|
|
offline mode is invoked when using the option \fB\-\-offline\fP or when
|
|
passing a file name to scrttv at startup. Example:
|
|
.INDENT 2.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
scrttv file.mseed
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SH WAVEFORM VISUALIZATION
|
|
.SS Stream selection
|
|
.sp
|
|
Without further configuration scrttv displays waveforms for streams defined
|
|
in global bindings. The selection can be refined by configuring
|
|
\fI\%streams.codes\fP and overridden on the command line using
|
|
\fB\-\-channels\fP\&.
|
|
.SS Stream hiding
|
|
.sp
|
|
Streams with \fI\%data latency\fP < \fI\%maxDelay\fP are hidden but
|
|
shown again when applicable. By default \fI\%maxDelay\fP is unconfigured and
|
|
hiding streams is inactive. For listing
|
|
streams hidden from one tab press \fBh\fP\&.
|
|
.SS Time windows
|
|
.sp
|
|
The reading waveforms from RecordStream, the data is displayed for a time
|
|
window which by default ends at current time or as given by the command\-line
|
|
option \fB\-\-end\-time\fP\&. Initially, the time window takes the length defined
|
|
in \fI\%bufferSize\fP or by the option \fB\-\-buffer\-size\fP\&. When reading data
|
|
directly from file in offline mode, the time window is set
|
|
from the time limits of the waveforms.
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
The \fBlength of visible time windows\fP can be adjusted by
|
|
\fI\%zooming\fP\&.
|
|
.IP \(bu 2
|
|
The \fBend time of the data\fP progresses in continuously in real time (UTC)
|
|
with the time of the computer clock unless fixed (\fBF8\fP). The end time is
|
|
fixed during startup when applying \fB\-\-end\-time\fP\&.
|
|
.IP \(bu 2
|
|
For \fBprogressing or rewinding by 30 minutes\fP press \fBAlt right\fP or
|
|
\fBAlt left\fP, respectively. Data will be loaded immediately.
|
|
.IP \(bu 2
|
|
You may also \fBfreely zoom\fP into any time window. Data and picks will be loaded
|
|
when pressing \fBCtrl + r\fP
|
|
.IP \(bu 2
|
|
\fBReturn to default real\-time processing\fP by pressing \fBCtrl + Shift + r\fP
|
|
or \fBN\fP\&.
|
|
.UNINDENT
|
|
.sp
|
|
\fBHINT:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
Gaps and overlaps in waveforms are indicated by yellow and purple areas,
|
|
respectively. The colors are configurable.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SS Zooming
|
|
.sp
|
|
Waveforms can be zoomed in and out interactively in amplitude and time. Use the
|
|
\fIView\fP menu or refer to the section \fI\%Hotkeys\fP for options. In
|
|
addition to the actions available from the View menu, zooming is supported by
|
|
mouse actions:
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
Zooming in in time: Right\-click on time axis, drag to the right. A green bar appears
|
|
which is the new time window. Dragging up or down (gray bar) disables zooming.
|
|
.IP \(bu 2
|
|
Zooming out in time: Right\-click on time axis, drag to the left. A red bar appears. The
|
|
longer the bar, the more you zoom out. Dragging up or down (gray bar)
|
|
disables zooming.
|
|
.IP \(bu 2
|
|
Zooming in time and amplitude: Mouse over a trace of interest, use
|
|
\fBCtrl + mouse wheel\fP for zooming in or out.
|
|
.IP \(bu 2
|
|
Zooming around a selected area: Press \fBz\fP and drag an area with while
|
|
pressing the left mouse button. Press \fBz\fP again for leaving the zoom
|
|
mode.
|
|
.UNINDENT
|
|
.SS Stream grouping
|
|
.sp
|
|
scrttv allows grouping of stations and even streams with different properties,
|
|
e.g. colors or color gradients.
|
|
.INDENT 0.0
|
|
.INDENT 2.5
|
|
[image]
|
|
Stations with 2 groups and different line color gradients. Ungrouped stations
|
|
are visible with default line properties. The applied filter
|
|
is shown in the lower left corner. The tooltip on top of station CX.PB19
|
|
is derived from \fI\%streams.group.$name.title\fP\&..UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
\fBConfiguration\fP
|
|
.sp
|
|
Adjust the scrttv module configuration (\fBscrttv.cfg\fP).
|
|
.INDENT 0.0
|
|
.IP 1. 3
|
|
Define the groups:
|
|
.INDENT 3.0
|
|
.IP \(bu 2
|
|
add a new group profile to \fBstreams.group\fP\&.
|
|
.IP \(bu 2
|
|
set the properties for this group profile. \fI\%Colors\fP and color
|
|
gradients are defined by hexadecimal values or by
|
|
\fI\%color keyword name\fP\&.
|
|
When choosing gradients the colors of the traces within one group will be
|
|
varied in alphabetic order of the streams.
|
|
.IP \(bu 2
|
|
set a group title in \fI\%streams.group.$name.title\fP\&.
|
|
.UNINDENT
|
|
.IP 2. 3
|
|
Register the groups in \fI\%streams.groups\fP\&.
|
|
.UNINDENT
|
|
.sp
|
|
\fBViewing groups\fP
|
|
.INDENT 0.0
|
|
.IP 1. 3
|
|
Open \fBscrttv\fP to view the data.
|
|
.IP 2. 3
|
|
Select \fISort by group\fP in the \fIInteraction\fP menu or use the hotkey \fB5\fP
|
|
to sort the traces by their groups.
|
|
.IP 3. 3
|
|
Mouse over a station belonging to a group. The tooltips shows the group title.
|
|
.IP 4. 3
|
|
For maintaining the sorting by groups adjust the \fBscrttv\fP module
|
|
configuration (\fBscrttv.cfg\fP):
|
|
.INDENT 3.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
resortAutomatically = false
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SS Phase picks and arrivals
|
|
.sp
|
|
Previous versions of scrttv (< 5.4) only displayed \fI\%picks\fP with the
|
|
colors indicating the pick evaluation mode along with the phase hint of the
|
|
pick:
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
red: automatic,
|
|
.IP \(bu 2
|
|
green: manual.
|
|
.UNINDENT
|
|
.sp
|
|
This hasn\(aqt really changed in later versions but additionally scrttv determines
|
|
an additional state of a pick called \fI\%arrival\fP\&. In scrttv a pick is
|
|
considered an arrival if it is associated to an valid origin. An origin is
|
|
called valid if its evaluation status is not REJECTED. When scrttv loads all
|
|
picks from the database for the currently visible time span it also checks if
|
|
each pick is associated with a valid origin and declares the arrival state if
|
|
the check yields true. The visibility of picks and arrivals can be toggled by
|
|
pressing \fBCtrl + p\fP and \fBCtrl + a\fP, respectively. \fBc\fP removes all
|
|
markers. The configuration parameter \fI\%showPicks\fP controls the default
|
|
visibility.
|
|
.sp
|
|
Picks and arrivals can be differentiated visually by their colours. When
|
|
configured in global module configuration, the same colours are being used
|
|
consistently as in any other GUI displaying both types, namely
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.picks.automatic\fP
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.picks.manual\fP
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.picks.undefined\fP
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.arrivals.automatic\fP
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.arrivals.manual\fP
|
|
.IP \(bu 2
|
|
\fI\%scheme.colors.arrivals.undefined\fP
|
|
.UNINDENT
|
|
.sp
|
|
That visual difference should support the operator in finding clusters of picks
|
|
and creating new location missed by the automatic system.
|
|
.sp
|
|
The next sections will only use the \fI\%pick\fP which can be used
|
|
interchangeable for pick or arrival.
|
|
.SS Record borders
|
|
.sp
|
|
The borders of records are toggled by using the hotkey \fBb\fP\&.
|
|
.INDENT 0.0
|
|
.INDENT 2.5
|
|
[image]
|
|
Record borders in box mode on top of waveforms..UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
Border properties can be adjusted and signed records can be visualized by colors
|
|
configured in the scheme parameters in \fBglobal.cfg\fP or \fBscrttv.cfg\fP:
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
\fI\%scheme.records.borders.drawMode\fP: Define where to draw borders, e.g. on top, bottom or as boxes.
|
|
.IP \(bu 2
|
|
\fBscheme.colors.records.borders.*\fP: Define pen and brush properties.
|
|
.UNINDENT
|
|
.SH WAVEFORM QUALITY CONTROL
|
|
.sp
|
|
Use scrttv for regular visual waveform inspection and for enabling or disabling
|
|
of stations. Disabled stations will not be used for automatic phase detections
|
|
and can be excluded from manual processing in \fI\%scolv\fP\&. They will also be
|
|
highlighted in \fI\%scmv\fP and \fI\%scqc\fP\&.
|
|
.sp
|
|
To enable or disable a station for automatic data processing in \fISeisComP\fP select
|
|
a station code with the mouse and drag the stations to the disable / enable tab
|
|
or simply double\-click on the station code in the respective tab.
|
|
.SH STREAM PROCESSING
|
|
.SS Filtering
|
|
.sp
|
|
scrttv allows filtering of waveforms. Any
|
|
\fI\%filter available in SeisComP\fP can be considered. The
|
|
filter selection dropdown menu (see \fI\%Figure above\fP)
|
|
and the hotkeys \fBg\fP or \fBd\fP can be used to toggle the list of filters.
|
|
This list of pre\-defined in \fI\%filter\fP or in \fI\%filters\fP\&. You may
|
|
switch between filtere and unfiltered data by pressing \fBf\fP\&. To show
|
|
filtered and raw data together use the hotkey \fBr\fP\&.
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
The list of filters defined in \fI\%filters\fP overwrites \fI\%filter\fP\&.
|
|
Activate \fI\%autoApplyFilter\fP to filter all traces at start\-up of scrttv
|
|
with the first filter defined in \fI\%filters\fP\&.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SS Gain correction
|
|
.sp
|
|
The stream gain is applied to waveforms and amplitude values are given in the
|
|
physical units defined in the inventory of the stream by default. For showing
|
|
amplitudes in counts, deactivate the option \fIApply gain\fP in the Interaction menu.
|
|
.SH INTERACTIVE SIGNAL DETECTION
|
|
.sp
|
|
Beside visual inspection of waveforms for quality control, scrttv can also be
|
|
used for interactive signal detection in real time or for selected time windows
|
|
in the past.
|
|
.SS Artificial origins
|
|
.INDENT 0.0
|
|
.INDENT 2.5
|
|
[image]
|
|
Artificial origin..UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
In case the operator recognizes several seismic signals which shall be processed
|
|
further, e.g. in \fI\%scolv\fP, an artificial/preliminary origin can be set by
|
|
either pressing the middle mouse
|
|
button on a trace or by opening the context menu (right mouse button) on a trace
|
|
and selecting \(dqCreate artificial origin\(dq. The following pop\-up window shows the
|
|
coordinates of the selected station and the time the click was made on the
|
|
trace. The coordinates and time define the hypocenter parameters of the the new
|
|
artificial origin without adding any arrivals.
|
|
Pressing \(dqCreate\(dq sends this origin to the LOCATION group. This artificial
|
|
origin is received e.g., by \fI\%scolv\fP and enables an immediate manual analysis
|
|
of the closest traces.
|
|
.sp
|
|
In order to send artificial origins and receive them in other GUIs
|
|
\fI\%commands.target\fP of the global module configuration must be configured
|
|
in line with \fI\%connection.username\fP of the receiving GUI module.
|
|
.sp
|
|
Alternatively, picks can be selected and preliminary origins can be created
|
|
which are sent to the system as regular origin objects, see section
|
|
\fI\%Pick association\fP\&.
|
|
.SS Pick association
|
|
.sp
|
|
scrttv comes with a minimal version of a phase associator and manual locator
|
|
based on selected and associated picks (Fig. \fI\%scrttv overview\fP). The
|
|
workflow is:
|
|
.INDENT 0.0
|
|
.IP 1. 3
|
|
Visually identify phase picks which potentially belong to an event of interest,
|
|
.IP 2. 3
|
|
\fI\%Select these picks\fP for automatic association,
|
|
.IP 3. 3
|
|
\fI\%Control\fP the locator,
|
|
.IP 4. 3
|
|
\fI\%Commit\fP created origins along with all associated
|
|
picks.
|
|
.UNINDENT
|
|
.sp
|
|
Origins are committed to the messaging system as manual but preliminary location.
|
|
In contrast to the artificial origin operation which requires an immediate
|
|
intervention with, e.g. \fI\%scolv\fP, this operation allows to store all those
|
|
detected origins and work on them later because they will be stored in the
|
|
database.
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
More detailed waveform and event analysis can be made in \fI\%scolv\fP\&.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.SS Pick selection
|
|
.sp
|
|
In order to select picks, the pick association mode must be entered. When done,
|
|
clicking with mouse onto the data and dragging a box (rubber band) around the
|
|
picks of interest will add the picks to a \(dqcart\(dq.
|
|
\(dqcart\(dq refers to the list of selected picks which then available in the
|
|
associator/locator control widget used for locating an origin.
|
|
.sp
|
|
Simply dragging a new box will remove all previously selected picks. Further
|
|
keyboard\-mouse options are:
|
|
.INDENT 0.0
|
|
.IP \(bu 2
|
|
\fBShift + drag\fP: Add more picks to the while keeping the previous selection.
|
|
.IP \(bu 2
|
|
\fBCtrl + drag\fP: Remove selected picks from the previous selection.
|
|
.UNINDENT
|
|
.sp
|
|
If at least one pick has been selected, the associator control will open as a
|
|
dock widget for locating based on the selected picks. There, individual picks
|
|
can also be removed from the selection by clicking on the close icon of each
|
|
pick item. Selected picks are also highlighted in the traces by a color
|
|
background bar.
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
A dock widget is a special kind of window which can be docked to any border
|
|
of the application or even displayed floated as kind of overlay window. The
|
|
position of the dock widget will be persistent across application restarts.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
At any change of the pick set, the associator will attempt a relocation
|
|
displaying the results in the details. Error message will show up at the top.
|
|
.SS Locating from picks
|
|
.sp
|
|
The associator control exposes all locators available in the system presenting them
|
|
in a dropdown list at the bottom. The locator which should be selected as default
|
|
can be controlled with \fI\%associator.defaultLocator\fP and its default
|
|
profile by \fI\%associator.defaultLocatorProfile\fP\&.
|
|
.sp
|
|
Whenever the operator changes any of the values, a new location attempt is being
|
|
made which can succeed or fail. A successful attempt will update the details,
|
|
a failed attempt will reset the details and print an error message at the top
|
|
of the window.
|
|
.sp
|
|
Each locator can be configured locally by clicking the wrench icon. This
|
|
configuration is not persistent across application restarts. It can be used
|
|
to tune and test various settings. Global locator configurations in the
|
|
configuration files are of course being considered by scrttv.
|
|
.sp
|
|
In addition to the locator and its profile a fixed depth can be set. By default
|
|
the depth is free and it is up to the locator implementation to assign a depth
|
|
to the origin. The depth dropdown list allows to set a predefined depth. The
|
|
list of depth values can be controlled with \fI\%associator.fixedDepths\fP\&.
|
|
.SS Committing a solution
|
|
.sp
|
|
Once you accept a solution you may press the button \(dqCommit\(dq be for sending it
|
|
to the messaging as a regular origin. The receiving message group is defined by
|
|
\fI\%messaging.groups.location\fP\&. The new origin is then grabbed by all
|
|
connected modules, e.g., \fI\%scevent\fP and possibly associated to an
|
|
\fI\%event\fP\&.
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
When considering non\-default message groups such as in multi\-pipeline systems,
|
|
\fI\%messaging.groups.location\fP should be configuring accordingly.
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
Alternatively, the button \(dqShow Details\(dq can be used to just send the origin to
|
|
the GUI group and let \fI\%scolv\fP or other GUIs pick it up and show it. This
|
|
will not store the origin in the database and works the same way as creating
|
|
\fI\%artificial origins\fP\&.
|
|
.SH HOTKEYS
|
|
.TS
|
|
center;
|
|
|l|l|.
|
|
_
|
|
T{
|
|
Hotkey
|
|
T} T{
|
|
Description
|
|
T}
|
|
_
|
|
T{
|
|
\fBF1\fP
|
|
T} T{
|
|
Open \fISeisComP\fP documentation
|
|
T}
|
|
_
|
|
T{
|
|
\fBShift+F1\fP
|
|
T} T{
|
|
Open scrttv documentation
|
|
T}
|
|
_
|
|
T{
|
|
\fBF2\fP
|
|
T} T{
|
|
Setup connection dialog
|
|
T}
|
|
_
|
|
T{
|
|
\fBF11\fP
|
|
T} T{
|
|
Toggle fullscreen
|
|
T}
|
|
_
|
|
T{
|
|
\fBESC\fP
|
|
T} T{
|
|
Set standard selection mode and deselect all traces
|
|
T}
|
|
_
|
|
T{
|
|
\fBc\fP
|
|
T} T{
|
|
Clear picker markers
|
|
T}
|
|
_
|
|
T{
|
|
\fBb\fP
|
|
T} T{
|
|
Toggle record borders
|
|
T}
|
|
_
|
|
T{
|
|
\fBh\fP
|
|
T} T{
|
|
List hidden streams
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+a\fP
|
|
T} T{
|
|
Toggle showing arrivals
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+p\fP
|
|
T} T{
|
|
Toggle showing picks
|
|
T}
|
|
_
|
|
T{
|
|
\fBn\fP
|
|
T} T{
|
|
Restore default display
|
|
T}
|
|
_
|
|
T{
|
|
\fBo\fP
|
|
T} T{
|
|
Align by origin time
|
|
T}
|
|
_
|
|
T{
|
|
\fBp\fP
|
|
T} T{
|
|
Enable pick selection mode
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+left\fP
|
|
T} T{
|
|
Reverse the data time window by buffer size
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+right\fP
|
|
T} T{
|
|
Advance the data time window by buffer size
|
|
T}
|
|
_
|
|
T{
|
|
\fBFiltering\fP
|
|
T} T{
|
|
T}
|
|
_
|
|
T{
|
|
\fBf\fP
|
|
T} T{
|
|
Toggle filtering
|
|
T}
|
|
_
|
|
T{
|
|
\fBd\fP
|
|
T} T{
|
|
Switch to previous filter in list if filtering is enabled.
|
|
T}
|
|
_
|
|
T{
|
|
\fBg\fP
|
|
T} T{
|
|
Switch to next filter in list if filtering is enabled.
|
|
T}
|
|
_
|
|
T{
|
|
\fBr\fP
|
|
T} T{
|
|
Toggle showing all records
|
|
T}
|
|
_
|
|
T{
|
|
\fBNavigation\fP
|
|
T} T{
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+f\fP
|
|
T} T{
|
|
Search traces
|
|
T}
|
|
_
|
|
T{
|
|
\fBup\fP
|
|
T} T{
|
|
Line up
|
|
T}
|
|
_
|
|
T{
|
|
\fBdown\fP
|
|
T} T{
|
|
Line down
|
|
T}
|
|
_
|
|
T{
|
|
\fBPgUp\fP
|
|
T} T{
|
|
Page up
|
|
T}
|
|
_
|
|
T{
|
|
\fBPgDn\fP
|
|
T} T{
|
|
Page down
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+PgUp\fP
|
|
T} T{
|
|
To top
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+PgDn\fP
|
|
T} T{
|
|
To bottom
|
|
T}
|
|
_
|
|
T{
|
|
\fBleft\fP
|
|
T} T{
|
|
Scroll left
|
|
T}
|
|
_
|
|
T{
|
|
\fBright\fP
|
|
T} T{
|
|
Scroll right
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+left\fP
|
|
T} T{
|
|
Align left
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+right\fP
|
|
T} T{
|
|
Align right
|
|
T}
|
|
_
|
|
T{
|
|
\fBNavigation and data\fP
|
|
T} T{
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+left\fP
|
|
T} T{
|
|
Rewind time window by 30\(aq and load data
|
|
T}
|
|
_
|
|
T{
|
|
\fBAlt+right\fP
|
|
T} T{
|
|
Progress time window by 30\(aq and load data
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+r\fP
|
|
T} T{
|
|
(Re)load data in current visible time range
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+Shift+r\fP
|
|
T} T{
|
|
Switch to real\-time with configured buffer size
|
|
T}
|
|
_
|
|
T{
|
|
\fBSorting\fP
|
|
T} T{
|
|
T}
|
|
_
|
|
T{
|
|
\fB1\fP
|
|
T} T{
|
|
Restore configuration order of traces
|
|
T}
|
|
_
|
|
T{
|
|
\fB2\fP
|
|
T} T{
|
|
Sort traces by distance
|
|
T}
|
|
_
|
|
T{
|
|
\fB3\fP
|
|
T} T{
|
|
Sort traces by station code
|
|
T}
|
|
_
|
|
T{
|
|
\fB4\fP
|
|
T} T{
|
|
Sort traces by network\-station code
|
|
T}
|
|
_
|
|
T{
|
|
\fB5\fP
|
|
T} T{
|
|
Sort traces by group
|
|
T}
|
|
_
|
|
T{
|
|
\fBZooming\fP
|
|
T} T{
|
|
T}
|
|
_
|
|
T{
|
|
\fB<\fP
|
|
T} T{
|
|
Horizontal zoom\-in
|
|
T}
|
|
_
|
|
T{
|
|
\fB>\fP
|
|
T} T{
|
|
Horizontal zoom\-out
|
|
T}
|
|
_
|
|
T{
|
|
\fBy\fP
|
|
T} T{
|
|
Vertical zoom\-out
|
|
T}
|
|
_
|
|
T{
|
|
\fBShift+y\fP
|
|
T} T{
|
|
Vertical zoom\-in
|
|
T}
|
|
_
|
|
T{
|
|
\fBs\fP
|
|
T} T{
|
|
Toggle amplitude normalization
|
|
T}
|
|
_
|
|
T{
|
|
\fBCtrl+mouse wheel\fP
|
|
T} T{
|
|
Vertical and horizontal zooming
|
|
T}
|
|
_
|
|
T{
|
|
\fBz\fP
|
|
T} T{
|
|
Enable/disable zooming: Drag window with left mouse button
|
|
T}
|
|
_
|
|
.TE
|
|
.SH MODULE CONFIGURATION
|
|
.nf
|
|
\fBetc/defaults/global.cfg\fP
|
|
\fBetc/defaults/scrttv.cfg\fP
|
|
\fBetc/global.cfg\fP
|
|
\fBetc/scrttv.cfg\fP
|
|
\fB~/.seiscomp/global.cfg\fP
|
|
\fB~/.seiscomp/scrttv.cfg\fP
|
|
.fi
|
|
.sp
|
|
.sp
|
|
scrttv inherits \fI\%global options\fP\&.
|
|
.INDENT 0.0
|
|
.TP
|
|
.B maxDelay
|
|
Default: \fB0\fP
|
|
.sp
|
|
Type: \fIint\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
If greater than 0, then all traces for which the data latency is
|
|
higher than this value are hidden. 0 disables the feature.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B resortAutomatically
|
|
Default: \fBtrue\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
If enabled, then all traces are sorted by distance when a new
|
|
origin arrives.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B showPicks
|
|
Default: \fBtrue\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
If enabled, picks are shown.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B mapPicks
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Map picks to best matching rows. This is important
|
|
if picks created on BHN should be shown but only the BHZ trace
|
|
is part of the list. Network code, station code and location code
|
|
must match anyway.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B filter
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Define the filter to be used when filtering is activated. This
|
|
parameter is ignored if \(dqfilters\(dq is configured.
|
|
This parameter exists mainly for backward compatibility.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B filters
|
|
Default: \fB\(dqRMHP(2)>>ITAPER(5)>>BW(3,0.5,8.0)\(dq,\(dqRMHP(2)>>ITAPER(5)>>BW_HP(3, 3)\(dq\fP
|
|
.sp
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
Define a list of filters that is cycles through when pressing
|
|
\(aqG\(aq or \(aqD\(aq. Filtering is toggled with \(aqF\(aq.
|
|
This parameter supersedes \(dqfilter\(dq. If undefined,
|
|
\(dqfilter\(dq is used instead. If defined, this filter
|
|
list is used exclusively and the filter option is ignored.
|
|
.sp
|
|
Formats:
|
|
.sp
|
|
\(dqfilter grammar\(dq: filter grammar is shown in
|
|
the scrttv filter selection and applied.
|
|
.sp
|
|
\(dqname;filter grammar\(dq: name is shown in the scrttv
|
|
filter selection but filter grammar is applied.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B autoApplyFilter
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Activate the first filter of the configured filter list
|
|
after startup. This is equivalent to pressing \(aqf\(aq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B bufferSize
|
|
Default: \fB1800\fP
|
|
.sp
|
|
Type: \fIint\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
Define the buffer size in seconds of the ring bu of each trace.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B allTracesInitiallyVisible
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
If set to true, all traces will be visible on application startup
|
|
independent of data availability.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B autoResetDelay
|
|
Default: \fB900\fP
|
|
.sp
|
|
Type: \fIint\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
Time span in seconds to switch back to the last view after an origin
|
|
caused resorting. The default is 15 min.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B 3c
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
If enabled, all three components (vertical, 1st and 2nd horizontal)
|
|
related to the detecStream will be shown rather than only the
|
|
component configured in global bindings. The option is ignored
|
|
when using \-\-no\-inventory.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B messaging.groups.config
|
|
Default: \fBCONFIG\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The messaging group to which config messages (such
|
|
as station enable/disable messages) are being sent.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B messaging.groups.location
|
|
Default: \fBLOCATION\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The messaging group to which location messages
|
|
are being sent.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.codes
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
The list of channel codes to be displayed. List items
|
|
may contain wildcards at any position and are separated
|
|
by comma. Wildcard support depends on RecordStream,
|
|
e.g.:
|
|
.sp
|
|
caps/sdsarchive: *.*.*.*
|
|
.sp
|
|
slink: NET.STA.*.*
|
|
.sp
|
|
The channel list is intersected with all channels
|
|
configured in inventory unless \-\-no\-inventory is used.
|
|
.sp
|
|
Examples:
|
|
.sp
|
|
default : display all streams configured by global
|
|
bindings
|
|
.sp
|
|
default, PF.BON.00.HH? : display default and all HH
|
|
streams of PF.BON.00
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.blacklist
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
If not empty then all stream patterns are part of the blacklist.
|
|
The blacklist is only active if \(dqstreams.codes\(dq
|
|
is omitted and the default stream list according to the
|
|
bindings is to be shown. Each pattern can include wildcards
|
|
(either ? or *). The pattern is checked against the channel
|
|
id which is a concatenation of network code, station code,
|
|
location code and channel code separated with a dot,
|
|
e.g. \(dqGE.MORC..BHZ\(dq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.rows
|
|
Type: \fIinteger\fP
|
|
.sp
|
|
Number of rows to show at once in one windows. If more traces
|
|
than rows are loaded, the are accessible by a scroll bar.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.groups
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Stream group profiles to be considered which must be defined in
|
|
group section. Use comma separation for a list of groups.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profiles
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Stream profiles to be considered which must be defined in
|
|
profile section. Use comma separation for a list of profiles.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.sort.*\fP
|
|
\fIConfigure the initial stream sorting.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.sort.mode
|
|
Default: \fBdistance\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The sort mode applied initially. Allowed values
|
|
are: config, distance, station, network, group.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.sort.latitude
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Latitude of the initial location for sorting traces.
|
|
Only valid if mode == distance.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.sort.longitude
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Longitude of the initial location for sorting traces.
|
|
Only valid if mode == distance.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.region.*\fP
|
|
\fIDefine a region used for clipping requested stations.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.region.lonmin
|
|
Default: \fB\-180.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Minimum longitude.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.region.lonmax
|
|
Default: \fB180.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Maximum longitude.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.region.latmin
|
|
Default: \fB\-90.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Minimum latitude.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.region.latmax
|
|
Default: \fB90.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIdeg\fP
|
|
.sp
|
|
Maximum latitude.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.group.*\fP
|
|
\fIDefiniton of stream groups shown in scrttv with unique features.\fP
|
|
\fIRegister the profiles in \(dqgroups\(dq to apply them.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.group.$name.*\fP
|
|
$name is a placeholder for the name to be used and needs to be added to \fI\%streams.groups\fP to become active.
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
streams.groups = a,b
|
|
streams.group.a.value1 = ...
|
|
streams.group.b.value1 = ...
|
|
# c is not active because it has not been added
|
|
# to the list of streams.groups
|
|
streams.group.c.value1 = ...
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.members
|
|
Type: \fIlist:string\fP
|
|
.sp
|
|
List of channels codes to be displayed within
|
|
this group. List items may contain wildcards at any position
|
|
and are separated by comma.
|
|
The list is intersected with all channels configured in inventory.
|
|
.sp
|
|
Example:
|
|
.sp
|
|
CX.*..BH?,PF.BON.00.HH? : all BH streams of the CX network
|
|
and all HH streams of PF.BON.00
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.title
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Title of the group visible as a tooltip of the traces.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.group.$name.pen.*\fP
|
|
\fIDefine the trace pen of the group.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.pen.color
|
|
Type: \fIcolor\fP
|
|
.sp
|
|
The color of the pen. If not given, the default
|
|
trace color is being used. The parameter is overridden
|
|
by \(dqstreams.group.$profile.gradient\(dq .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.pen.gradient
|
|
Type: \fIgradient\fP
|
|
.sp
|
|
Define the color gradient used to generate the
|
|
trace color for each group member. When given, the
|
|
value in \(dqstreams.group.$profile.pen.color\(dq
|
|
is ignored. The colors are distributed equally and
|
|
given in hexadecimal representation or by or
|
|
color keyword names\&.
|
|
The stop points
|
|
can be set at any value. The final trace color
|
|
will be interpolated from the normalized gradient
|
|
where the value range is scaled to [0,1].
|
|
.sp
|
|
Format: value1:color1,value2:color2
|
|
.sp
|
|
Examples:
|
|
.sp
|
|
0:yellow,1:green
|
|
.sp
|
|
0:FFBF00,1:C70039
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.pen.style
|
|
Default: \fBSolidLine\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The style of the pen. Supported values are: NoPen,
|
|
SolidLine, DashLine, DotLine, DashDotLine,
|
|
DashDotDotLine.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.group.$name.pen.width
|
|
Default: \fB1.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIpx\fP
|
|
.sp
|
|
The width of the pen.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.*\fP
|
|
\fIDefiniton of profiles for streams shown with unique decorations.\fP
|
|
\fIRegister the profiles in \(dqprofiles\(dq to apply them.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.*\fP
|
|
$name is a placeholder for the name to be used and needs to be added to \fI\%streams.profiles\fP to become active.
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
.sp
|
|
.nf
|
|
.ft C
|
|
streams.profiles = a,b
|
|
streams.profile.a.value1 = ...
|
|
streams.profile.b.value1 = ...
|
|
# c is not active because it has not been added
|
|
# to the list of streams.profiles
|
|
streams.profile.c.value1 = ...
|
|
.ft P
|
|
.fi
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.match
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Stream applying this profile to. Use regular expressions
|
|
for defining multiple streams. Examples:
|
|
.sp
|
|
GR.BFO.00.BHZ: One stream on vertical component
|
|
.sp
|
|
GR.*.00.BHZ: All stations from GR network and their
|
|
vertical components.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.description
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Text added to streams.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minMaxMargin
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Fraction of trace amplitude added to trace widgets.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.unit
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The physical unit shown along with stream maximum and
|
|
minimum values.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.gain
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
The gain applied to scale trace amplitudes. 0 disables
|
|
showing trace amplitude value
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.fixedScale
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.minimum.*\fP
|
|
\fIProperties defining the minimum line on each trace.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.value
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Value at which to draw a line.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.minimum.pen.*\fP
|
|
\fILine properties.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.pen.width
|
|
Default: \fB1\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.pen.style
|
|
Default: \fBsolidline\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.pen.color
|
|
Default: \fB000000ff\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.minimum.brush.*\fP
|
|
\fIProperties of the area below the minimum.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.brush.style
|
|
Default: \fBnobrush\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.minimum.brush.color
|
|
Default: \fB000000ff\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.maximum.*\fP
|
|
\fIProperties defining the maximum line on each trace.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.value
|
|
Default: \fB0.0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Value at which to draw a line.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.maximum.pen.*\fP
|
|
\fILine properties.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.pen.width
|
|
Default: \fB1\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.pen.style
|
|
Default: \fBsolidline\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.pen.color
|
|
Default: \fB000000ff\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBstreams.profile.$name.maximum.brush.*\fP
|
|
\fIProperties of the area above the maximum.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.brush.style
|
|
Default: \fBnobrush\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B streams.profile.$name.maximum.brush.color
|
|
Default: \fB000000ff\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBassociator.*\fP
|
|
\fIDefine parameters for manually associating phases to origin and\fP
|
|
\fIfor locating the origins.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B associator.defaultLocator
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The locator which is activated as default locator.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B associator.defaultLocatorProfile
|
|
Type: \fIstring\fP
|
|
.sp
|
|
The locator profile which is activated as default profile for
|
|
the default locator.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B associator.fixedDepths
|
|
Default: \fB0, 10, 18\fP
|
|
.sp
|
|
Type: \fIlist:double\fP
|
|
.sp
|
|
Unit: \fIkm\fP
|
|
.sp
|
|
A list of depths used to populate the locator depth selection
|
|
dropdown list.
|
|
.UNINDENT
|
|
.sp
|
|
\fBNOTE:\fP
|
|
.INDENT 0.0
|
|
.INDENT 3.5
|
|
\fBspectrogram.*\fP
|
|
\fIDefine parameters for spectrogram representation.\fP
|
|
.UNINDENT
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.smoothing
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Whether to plot the spectrogram filtered bilinearily.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.logScale
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Whether to use logarithmic frequency scale.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.normalization
|
|
Default: \fBfixed\fP
|
|
.sp
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Which amplitude normalization mode to use: \(dqfixed\(dq,
|
|
\(dqfrequency\(dq or \(dqtime\(dq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.axis
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
Whether to show the frequency axis.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.minimumAmplitude
|
|
Default: \fB\-15\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIlog(ps)\fP
|
|
.sp
|
|
The lower bound of the static amplitude range give as logarithm of
|
|
the power spectrum (log(real**2 + imag**2)).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.maximumAmplitude
|
|
Default: \fB\-5\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIlog(ps)\fP
|
|
.sp
|
|
The upper bound of the static amplitude range give as logarithm of
|
|
the power spectrum (log(real**2 + imag**2)).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.minimumFrequency
|
|
Default: \fB0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIHz\fP
|
|
.sp
|
|
The lower bound of the frequency to be shown.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.maximumFrequency
|
|
Default: \fB0\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIHz\fP
|
|
.sp
|
|
The upper bound of the frequency to be shown. Zero is a special
|
|
value and means \(dqauto\(dq and sets the maximum
|
|
frequency from the spectra.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.timeSpan
|
|
Default: \fB20\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
Unit: \fIs\fP
|
|
.sp
|
|
The time span of each data slice used to compute the
|
|
frequency spectrum.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B spectrogram.overlap
|
|
Default: \fB0.5\fP
|
|
.sp
|
|
Type: \fIdouble\fP
|
|
.sp
|
|
The overlap of the data time window between zero and one
|
|
(exclusive).
|
|
.UNINDENT
|
|
.SH COMMAND-LINE OPTIONS
|
|
.sp
|
|
\fBscrttv [options] [miniSEED file]\fP
|
|
.SS Generic
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-h, \-\-help
|
|
Show help message.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-V, \-\-version
|
|
Show version information.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-file arg
|
|
Use alternative configuration file. When this option is
|
|
used the loading of all stages is disabled. Only the
|
|
given configuration file is parsed and used. To use
|
|
another name for the configuration create a symbolic
|
|
link of the application or copy it. Example:
|
|
scautopick \-> scautopick2.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-plugins arg
|
|
Load given plugins.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-auto\-shutdown arg
|
|
Enable/disable self\-shutdown because a master module shutdown.
|
|
This only works when messaging is enabled and the master
|
|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
|
for the master module).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-module arg
|
|
Set the name of the master\-module used for auto\-shutdown.
|
|
This is the application name of the module actually
|
|
started. If symlinks are used, then it is the name of
|
|
the symlinked application.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-username arg
|
|
Set the name of the master\-username of the messaging
|
|
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
|
|
given as well, this parameter is ignored.
|
|
.UNINDENT
|
|
.SS Verbosity
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-verbosity arg
|
|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
|
4:debug.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-v, \-\-v
|
|
Increase verbosity level (may be repeated, eg. \-vv).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-q, \-\-quiet
|
|
Quiet mode: no logging output.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-component arg
|
|
Limit the logging to a certain component. This option can
|
|
be given more than once.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-s, \-\-syslog
|
|
Use syslog logging backend. The output usually goes to
|
|
/var/lib/messages.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-l, \-\-lockfile arg
|
|
Path to lock file.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-console arg
|
|
Send log output to stdout.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-debug
|
|
Execute in debug mode.
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-log\-file arg
|
|
Use alternative log file.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-print\-component arg
|
|
For each log entry print the component right after the
|
|
log level. By default the component output is enabled
|
|
for file output but disabled for console output.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-trace
|
|
Execute in trace mode.
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 \-\-print\-component=1
|
|
\-\-print\-context=1 .
|
|
.UNINDENT
|
|
.SS Messaging
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-u, \-\-user arg
|
|
Overrides configuration parameter \fI\%connection.username\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-H, \-\-host arg
|
|
Overrides configuration parameter \fI\%connection.server\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-t, \-\-timeout arg
|
|
Overrides configuration parameter \fI\%connection.timeout\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-g, \-\-primary\-group arg
|
|
Overrides configuration parameter \fI\%connection.primaryGroup\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-S, \-\-subscribe\-group arg
|
|
A group to subscribe to.
|
|
This option can be given more than once.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-content\-type arg
|
|
Overrides configuration parameter \fI\%connection.contentType\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-start\-stop\-msg arg
|
|
Set sending of a start and a stop message.
|
|
.UNINDENT
|
|
.SS Database
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-db\-driver\-list
|
|
List all supported database drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-d, \-\-database arg
|
|
The database connection string, format:
|
|
\fI\%service://user:pwd@host/database\fP\&.
|
|
\(dqservice\(dq is the name of the database driver which
|
|
can be queried with \(dq\-\-db\-driver\-list\(dq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-module arg
|
|
The config module to use.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-inventory\-db arg
|
|
Load the inventory from the given database or file, format:
|
|
[\fI\%service://]location\fP .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-db\-disable
|
|
Do not use the database at all
|
|
.UNINDENT
|
|
.SS Records
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-driver\-list
|
|
List all supported record stream drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-I, \-\-record\-url arg
|
|
The recordstream source URL, format:
|
|
[\fI\%service://\fP]location[#type].
|
|
\(dqservice\(dq is the name of the recordstream driver
|
|
which can be queried with \(dq\-\-record\-driver\-list\(dq.
|
|
If \(dqservice\(dq is not given, \(dq\fI\%file://\fP\(dq is
|
|
used.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-file arg
|
|
Specify a file as record source.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-type arg
|
|
Specify a type for the records being read.
|
|
.UNINDENT
|
|
.SS Options
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-i, \-\-input\-file xml
|
|
Load picks in given XML file during startup
|
|
.UNINDENT
|
|
.SS Mode
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-filter arg
|
|
Overrides configuration parameter \fI\%filter\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-offline
|
|
Do not connect to a messaging server and do not use the
|
|
database.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-no\-inventory
|
|
Do not read streams from inventory but display all streams
|
|
available from the specified record source. This option may
|
|
be combined with the streams.codes parameter to filter the
|
|
available streams.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-end\-time arg
|
|
Set the acquisition end time, e.g. \(aq2017\-09\-08 13:30:00\(aq,
|
|
default: \(aqgmt\(aq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-buffer\-size arg
|
|
Overrides configuration parameter \fI\%bufferSize\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-max\-delay arg
|
|
Overrides configuration parameter \fI\%maxDelay\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-start\-at\-now
|
|
Subscribe to data starting at now rather than now \- bufferSize
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-rt
|
|
Do not ask for time window at data server. This might be
|
|
important if e.g. Seedlink does not allow time window
|
|
extraction.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-map\-picks
|
|
Overrides configuration parameter \fI\%mapPicks\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-3c
|
|
Overrides configuration parameter \fI\%3c\fP\&.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-channels
|
|
Channel(s) to display. The channel code may contain wildcards
|
|
at any position but the support of wildcards depends on
|
|
RecordStream. Repeat the option for multiple
|
|
channel groups. Examples:
|
|
.sp
|
|
default : all streams configured by global bindings.
|
|
.sp
|
|
GE.*.*.HH? : all HH channels of all stations from GE network.
|
|
.UNINDENT
|
|
.SS Cities
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-city\-xml arg
|
|
The path to the cities XML file. This overrides the default
|
|
paths. Compare with the global parameter \(dqcitiesXML\(dq.
|
|
.UNINDENT
|
|
.SS User interface
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-F, \-\-full\-screen
|
|
Start the application filling the entire screen.
|
|
This only works with GUI applications.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-N, \-\-non\-interactive
|
|
Use non\-interactive presentation mode. This only works with
|
|
GUI applications.
|
|
.UNINDENT
|
|
.SH AUTHOR
|
|
gempa GmbH, GFZ Potsdam
|
|
.SH COPYRIGHT
|
|
gempa GmbH, GFZ Potsdam
|
|
.\" Generated by docutils manpage writer.
|
|
.
|