252 lines
5.4 KiB
Groff
252 lines
5.4 KiB
Groff
.\" Man page generated from reStructuredText.
|
|
.
|
|
.
|
|
.nr rst2man-indent-level 0
|
|
.
|
|
.de1 rstReportMargin
|
|
\\$1 \\n[an-margin]
|
|
level \\n[rst2man-indent-level]
|
|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
-
|
|
\\n[rst2man-indent0]
|
|
\\n[rst2man-indent1]
|
|
\\n[rst2man-indent2]
|
|
..
|
|
.de1 INDENT
|
|
.\" .rstReportMargin pre:
|
|
. RS \\$1
|
|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
|
. nr rst2man-indent-level +1
|
|
.\" .rstReportMargin post:
|
|
..
|
|
.de UNINDENT
|
|
. RE
|
|
.\" indent \\n[an-margin]
|
|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.nr rst2man-indent-level -1
|
|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
|
..
|
|
.TH "SCREPICK" "1" "Sep 22, 2025" "6.9.0" "SeisComP"
|
|
.SH NAME
|
|
screpick \- SeisComP Documentation
|
|
.sp
|
|
\fBReads an XML file of picks and repicks them using a post picker. The
|
|
picks will be modified in place and written to another XML file.\fP
|
|
.SH MODULE CONFIGURATION
|
|
.nf
|
|
\fBetc/defaults/global.cfg\fP
|
|
\fBetc/defaults/screpick.cfg\fP
|
|
\fBetc/global.cfg\fP
|
|
\fBetc/screpick.cfg\fP
|
|
\fB~/.seiscomp/global.cfg\fP
|
|
\fB~/.seiscomp/screpick.cfg\fP
|
|
.fi
|
|
.sp
|
|
.sp
|
|
screpick inherits \fI\%global options\fP\&.
|
|
.INDENT 0.0
|
|
.TP
|
|
.B picker
|
|
Type: \fIstring\fP
|
|
.sp
|
|
Picker interface to be used for repicking.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B anyPhase
|
|
Default: \fBfalse\fP
|
|
.sp
|
|
Type: \fIboolean\fP
|
|
.sp
|
|
If enabled then all picks will be processed. Otherwise only
|
|
P phases or picks without a phase hint will be considered.
|
|
.UNINDENT
|
|
.SH COMMAND-LINE OPTIONS
|
|
.SS Generic
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-h, \-\-help
|
|
Show help message.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-V, \-\-version
|
|
Show version information.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-file arg
|
|
Use alternative configuration file. When this option is
|
|
used the loading of all stages is disabled. Only the
|
|
given configuration file is parsed and used. To use
|
|
another name for the configuration create a symbolic
|
|
link of the application or copy it. Example:
|
|
scautopick \-> scautopick2.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-plugins arg
|
|
Load given plugins.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-D, \-\-daemon
|
|
Run as daemon. This means the application will fork itself
|
|
and doesn\(aqt need to be started with &.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-auto\-shutdown arg
|
|
Enable/disable self\-shutdown because a master module shutdown.
|
|
This only works when messaging is enabled and the master
|
|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
|
for the master module).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-module arg
|
|
Set the name of the master\-module used for auto\-shutdown.
|
|
This is the application name of the module actually
|
|
started. If symlinks are used, then it is the name of
|
|
the symlinked application.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-shutdown\-master\-username arg
|
|
Set the name of the master\-username of the messaging
|
|
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
|
|
given as well, this parameter is ignored.
|
|
.UNINDENT
|
|
.SS Verbosity
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-verbosity arg
|
|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
|
4:debug.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-v, \-\-v
|
|
Increase verbosity level (may be repeated, eg. \-vv).
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-q, \-\-quiet
|
|
Quiet mode: no logging output.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-component arg
|
|
Limit the logging to a certain component. This option can
|
|
be given more than once.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-s, \-\-syslog
|
|
Use syslog logging backend. The output usually goes to
|
|
/var/lib/messages.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-l, \-\-lockfile arg
|
|
Path to lock file.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-console arg
|
|
Send log output to stdout.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-debug
|
|
Execute in debug mode.
|
|
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-log\-file arg
|
|
Use alternative log file.
|
|
.UNINDENT
|
|
.SS Database
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-db\-driver\-list
|
|
List all supported database drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-d, \-\-database arg
|
|
The database connection string, format:
|
|
\fI\%service://user:pwd@host/database\fP\&.
|
|
\(dqservice\(dq is the name of the database driver which
|
|
can be queried with \(dq\-\-db\-driver\-list\(dq.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-config\-module arg
|
|
The config module to use.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-inventory\-db arg
|
|
Load the inventory from the given database or file, format:
|
|
[\fI\%service://]location\fP .
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-db\-disable
|
|
Do not use the database at all
|
|
.UNINDENT
|
|
.SS Records
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-driver\-list
|
|
List all supported record stream drivers.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-I, \-\-record\-url arg
|
|
The recordstream source URL, format:
|
|
[\fI\%service://\fP]location[#type].
|
|
\(dqservice\(dq is the name of the recordstream driver
|
|
which can be queried with \(dq\-\-record\-driver\-list\(dq.
|
|
If \(dqservice\(dq is not given, \(dq\fI\%file://\fP\(dq is
|
|
used.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-file arg
|
|
Specify a file as record source.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-record\-type arg
|
|
Specify a type for the records being read.
|
|
.UNINDENT
|
|
.SS Input
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-\-ep file
|
|
Name of input XML file (SCML) with all picks for offline
|
|
processing.
|
|
.UNINDENT
|
|
.SS Picker
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-P, \-\-picker interface
|
|
Defines the picker interface to be used. It must be part of
|
|
the common libraries or loaded as plugin.
|
|
.UNINDENT
|
|
.INDENT 0.0
|
|
.TP
|
|
.B \-A, \-\-any\-phase
|
|
Accept any pick regardless of its phase hint.
|
|
.UNINDENT
|
|
.SH AUTHOR
|
|
gempa GmbH, GFZ Potsdam
|
|
.SH COPYRIGHT
|
|
gempa GmbH, GFZ Potsdam
|
|
.\" Generated by docutils manpage writer.
|
|
.
|