73 lines
2.6 KiB
XML
73 lines
2.6 KiB
XML
<?xml version="1.0" encoding="UTF-8"?>
|
|
<seiscomp>
|
|
<plugin name="FixedHypocenter">
|
|
<extends>global</extends>
|
|
<description>Locator for re-computing source time with fixed hypocenter</description>
|
|
<configuration>
|
|
<group name="FixedHypocenter">
|
|
<description>
|
|
Locator parameters: FixedHypocenter
|
|
</description>
|
|
<parameter name="profiles" type="list:string" default="LOCSAT/iasp91,LOCSAT/tab">
|
|
<description>
|
|
Defines a list of available travel time tables. Each item
|
|
is a tuple separated by a slash with format "[interface]/[model]".
|
|
Built-in interfaces are "LOCSAT" and "libtau".
|
|
Other interfaces might be added via plugins. Please check their
|
|
documentation for the required interface name.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="lat" type="double">
|
|
<description>
|
|
The fixed latitude to use. If not set then this
|
|
value is read from the input origin.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="lon" type="double">
|
|
<description>
|
|
The fixed longitude to use. If not set then this
|
|
value is read from the input origin.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="depth" type="double">
|
|
<description>
|
|
The fixed depth to use. If not set then this
|
|
value is read from the input origin.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="time" type="string">
|
|
<description>
|
|
The fixed time to use. If not set then this
|
|
value is read from the input origin.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="usePickUncertainties" type="boolean" default="false">
|
|
<description>
|
|
Whether to use pick time uncertainties rather than a fixed
|
|
time error. If true, then the uncertainties are retrieved from
|
|
each individual pick object. If they are not defined, then the
|
|
default pick time uncertainty as defined by defaultTimeError
|
|
will be used instead.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="defaultTimeError" type="double" default="1.0" unit="s">
|
|
<description>
|
|
The default pick time uncertainty if pick uncertainties are
|
|
not going to be used or if they are absent.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="degreesOfFreedom" type="int" default="8">
|
|
<description>
|
|
Number of degrees of freedom used for error estimate.
|
|
</description>
|
|
</parameter>
|
|
<parameter name="confLevel" type="double" default="0.9">
|
|
<description>
|
|
Confidence level between 0.5 and 1.
|
|
</description>
|
|
</parameter>
|
|
</group>
|
|
</configuration>
|
|
</plugin>
|
|
</seiscomp>
|