[texas] Add tuned parameters

This commit is contained in:
2025-10-10 11:04:12 +02:00
parent 7086945aa7
commit 2ff097f9d1
134 changed files with 1060 additions and 0 deletions

View File

@ -0,0 +1,62 @@
# The sensor location code of the preferred stream used e.g. by scautopick and
# scrttv.
detecLocid = 00
# The channel code of the preferred stream used by e.g. scautopick and scrttv.
# If no component code is given, the vertical component will be fetched from
# inventory considering the channel orientation (azimuth, dip). If that
# approach fails, 'Z' will be appended and used as fallback. Do not use regular
# expressions!
detecStream = HHZ
# Override the relative data acquisition time (relative to the triggering
# pick). This adds a margin to the actual processing and is useful to
# initialize the filter (Example: bandpass). The data is not used at all until
# signalBegin is reached. The data time window start is the minimum of
# noiseBegin and signalBegin.
picker.AIC.noiseBegin = -10
# Override the default time (relative to the trigger time) of the begin of the
# signal window used to pick.
picker.AIC.signalBegin = -2
# Override the default time (relative to the trigger time) of the begin of the
# signal window used to pick.
picker.AIC.signalEnd = 1
# Override the default filter which is "raw". The typical filter grammar can be
# used.
picker.AIC.filter = "RMHP(5)>>ITAPER(3)>>BW(3,3,-0.4)"
# Mininum SNR as returned from AIC for accepting picks.
picker.AIC.minSNR = 3
# Start time of the signal processing relative to the triggering P pick. This
# adds a margin to the actual processing and is useful to initialize the filter
# (e.g. STALTA). The data is not used at all for detection until signalBegin is
# reached.
spicker.AIC.noiseBegin = -10
# Start time of the S-phase detector relative to the triggering P pick.
# Delaying the detector ignores P-coda and early signals, e.g. due to P-S phase
# conversions at shallow depths.
spicker.AIC.signalBegin = 0.3
# End time of the S-phase detector relative to the triggering P pick.
spicker.AIC.signalEnd = 5
# Filter applied on the raw horizontal traces to compute the L2 trace. As a
# minimum remove offsets. S-AIC-V, filters the raw vertical trace computing the
# filtered vertical trace.
spicker.AIC.filter = "RMHP(1)>>ITAPER(2)>>BW(3,3,15)"
# The AIC time window stepping in seconds. For every step the window is
# expanded by step and the AIC is computed.
spicker.AIC.step = 0.3
# Mininum SNR as returned from AIC for accepting a detection.
spicker.AIC.minSNR = 5
# Minimum number of hits for a particular pick time when the running AIC is
# computed for accepting a detection.
spicker.AIC.minCnt = 3