[seiscomp, scanloc] Install, add .gitignore
This commit is contained in:
795
share/man/man1/scesv.1
Normal file
795
share/man/man1/scesv.1
Normal file
@ -0,0 +1,795 @@
|
||||
.\" Man page generated from reStructuredText.
|
||||
.
|
||||
.
|
||||
.nr rst2man-indent-level 0
|
||||
.
|
||||
.de1 rstReportMargin
|
||||
\\$1 \\n[an-margin]
|
||||
level \\n[rst2man-indent-level]
|
||||
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
-
|
||||
\\n[rst2man-indent0]
|
||||
\\n[rst2man-indent1]
|
||||
\\n[rst2man-indent2]
|
||||
..
|
||||
.de1 INDENT
|
||||
.\" .rstReportMargin pre:
|
||||
. RS \\$1
|
||||
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
||||
. nr rst2man-indent-level +1
|
||||
.\" .rstReportMargin post:
|
||||
..
|
||||
.de UNINDENT
|
||||
. RE
|
||||
.\" indent \\n[an-margin]
|
||||
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
.nr rst2man-indent-level -1
|
||||
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
||||
..
|
||||
.TH "SCESV" "1" "Sep 22, 2025" "6.9.0" "SeisComP"
|
||||
.SH NAME
|
||||
scesv \- SeisComP Documentation
|
||||
.sp
|
||||
\fBEvent summary view.\fP
|
||||
.SH DESCRIPTION
|
||||
.sp
|
||||
scesv is the summary display of the event parameters. It shows the primary information
|
||||
about the current event including location, time, strength, type and processing status.
|
||||
Additional to the current event older events can also be chosen from the eventlist in the
|
||||
events tab.
|
||||
.sp
|
||||
The two tabs of scesv are
|
||||
.INDENT 0.0
|
||||
.IP \(bu 2
|
||||
Events tab showing the list of loaded events, compare Fig. \fI\%Eventlist tab\fP
|
||||
.IP \(bu 2
|
||||
Summary tab with the details of the selected event, see Fig. \fI\%Summary tab\fP\&.
|
||||
.UNINDENT
|
||||
.SH EVENTS TAB
|
||||
.sp
|
||||
The Events tab shows the eventlist of the time span defined on the bottom side of
|
||||
the window. A the Events tab is also available for other GUIs, such as \fI\%scolv\fP
|
||||
it can be configured in the global module configuration.
|
||||
The \fI\%description of the Events tab in scolv\fP provides more
|
||||
details.
|
||||
.INDENT 0.0
|
||||
.INDENT 2.5
|
||||
[image]
|
||||
Eventlist tab
|
||||
Tab1\-2: Summary/Events tab, EventList: list of the last events with summarized information,
|
||||
List options: Show fake events, Reading 1: spinbox to limit timespan of displayed events (in days),
|
||||
Reading 2: spinboxes to limit timespan of displayed events (specified dates), Status: connection status
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
As for \fI\%scolv\fP filtering of the event list and custom information can be
|
||||
added to the event list by configuration. Read the scolv documentation on
|
||||
\fI\%event filtering\fP and \fI\%custom action\fP
|
||||
for the details.
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.SH SUMMARY TAB
|
||||
.sp
|
||||
The most recent (default) or the event selected from the event list is shown in
|
||||
the Summary tab, see Fig. \fI\%Summary tab\fP\&.
|
||||
Here the information are highlighted in four sections:
|
||||
.TS
|
||||
center;
|
||||
|l|l|.
|
||||
_
|
||||
T{
|
||||
section
|
||||
T} T{
|
||||
description
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Time
|
||||
T} T{
|
||||
Orign time in UTC and relative to now
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Region
|
||||
T} T{
|
||||
A map of the region and location with the event and stations
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Magnitude
|
||||
T} T{
|
||||
Different magnitude types, the values and counts
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Hypocenter
|
||||
T} T{
|
||||
Origin information with location, depth, azimuthal gap etc.
|
||||
T}
|
||||
_
|
||||
.TE
|
||||
.INDENT 0.0
|
||||
.INDENT 2.5
|
||||
[image]
|
||||
Summary tab
|
||||
Tab1\-2: Summary/Events tab, Origin Time: origin time in UTC and relative to now, Map: map with region
|
||||
and location and stations, Magnitude: different magnitude types with values and counts,
|
||||
Origin Info: hypocenter information with position, phase count and azimuthal gap,
|
||||
Event: earthquake location, Station: station with ray\-path, Details: \(dqShow Details\(dq button to open
|
||||
detailed information in \fI\%scolv\fP, Event Type: event type combo box to set event type, Status: connection status
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.SH HOTKEYS
|
||||
.TS
|
||||
center;
|
||||
|l|l|.
|
||||
_
|
||||
T{
|
||||
Hotkey
|
||||
T} T{
|
||||
Description
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF1\fP
|
||||
T} T{
|
||||
Open \fISeisComP\fP documentation
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Shift + \fBF1\fP
|
||||
T} T{
|
||||
Open scesv documentation
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF2\fP
|
||||
T} T{
|
||||
Setup connection dialog
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF6\fP
|
||||
T} T{
|
||||
Show propagation of P and S wave
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF7\fP
|
||||
T} T{
|
||||
Show focal mechanism by beach ball
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Shift + \fBF7\fP
|
||||
T} T{
|
||||
Show focal mechanism by beach ball
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF8\fP
|
||||
T} T{
|
||||
Toggle auto update
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF9\fP
|
||||
T} T{
|
||||
Show raypaths and associated stations
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF10\fP
|
||||
T} T{
|
||||
Toggle tabs
|
||||
T}
|
||||
_
|
||||
T{
|
||||
\fBF11\fP
|
||||
T} T{
|
||||
Toggle fullscreen
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Mouse wheel
|
||||
T} T{
|
||||
Zoom map in/out
|
||||
T}
|
||||
_
|
||||
T{
|
||||
Double click
|
||||
T} T{
|
||||
Center map
|
||||
T}
|
||||
_
|
||||
.TE
|
||||
.SH MODULE CONFIGURATION
|
||||
.nf
|
||||
\fBetc/defaults/global.cfg\fP
|
||||
\fBetc/defaults/scesv.cfg\fP
|
||||
\fBetc/global.cfg\fP
|
||||
\fBetc/scesv.cfg\fP
|
||||
\fB~/.seiscomp/global.cfg\fP
|
||||
\fB~/.seiscomp/scesv.cfg\fP
|
||||
.fi
|
||||
.sp
|
||||
.sp
|
||||
scesv inherits \fI\%global options\fP\&.
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B loadEventDB
|
||||
Default: \fB1\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdays\fP
|
||||
.sp
|
||||
Number of days to preload if scesv is started.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B showLastAutomaticSolution
|
||||
Default: \fBfalse\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the last automatic solution is displayed next to the
|
||||
current solution in the summary panel. If the last automatic
|
||||
solution differs from the current solution it is displayed
|
||||
in red. If both solutions match it is displayed in gray.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B showOnlyMostRecentEvent
|
||||
Default: \fBtrue\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, only the most recent event is shown even if an update of
|
||||
an older event is being received.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B recenterMap
|
||||
Default: \fBtrue\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the map is centered around the most recent event event.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B enableFixAutomaticSolutions
|
||||
Default: \fBfalse\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, an additional button is displayed which allows to
|
||||
switch back the latest automatic solution. This button triggers
|
||||
an command for scevent to prioritize automatic solutions until
|
||||
the next manual solution is available.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B visibleMagnitudes
|
||||
Default: \fBM,MLv,mb,mB,Mw(mB)\fP
|
||||
.sp
|
||||
Type: \fIlist:string\fP
|
||||
.sp
|
||||
A list of magnitude types to be displayed.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B button0
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Label of button0 which triggers script0.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B button1
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Label of button1 which triggers script1.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B ignoreOtherEvents
|
||||
Default: \fBtrue\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If the event type is either \(dqother\(dq or
|
||||
\(dqnot existing\(dq and this flag is true then the
|
||||
event will not be shown.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script0
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Path to a script if button0 is clicked.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script1
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Path to a script if button1 is clicked.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script0.exportMap
|
||||
Default: \fBfalse\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the current map is exported to file.
|
||||
The filename is appened to the parameter list of script0.
|
||||
The script has to take ownership of the file.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script0.oldStyle
|
||||
Default: \fBtrue\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the parameter list of script0 is event ID,
|
||||
arrival count, magnitude, description.
|
||||
.sp
|
||||
If disabled, the parameter list of script0 is event ID,
|
||||
preferredOriginID, preferredMagnitudeID,
|
||||
preferredFocalMechanismID.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script1.exportMap
|
||||
Default: \fBfalse\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the current map is exported to file.
|
||||
The filename is appened to the parameter list of script1.
|
||||
The script has to take ownership of the file.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B scripts.script1.oldStyle
|
||||
Default: \fBtrue\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
If enabled, the parameter list of script1 is event ID,
|
||||
arrivalCount, magnitude, description.
|
||||
.sp
|
||||
If disabled, the parameter list of script1 is event ID,
|
||||
preferredOriginID, preferredMagnitudeID,
|
||||
preferredFocalMechanismID.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B summary.borders
|
||||
Default: \fBfalse\fP
|
||||
.sp
|
||||
Type: \fIboolean\fP
|
||||
.sp
|
||||
Draw borders in the summary panel.
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
\fBdisplay.*\fP
|
||||
\fIAdjust content or display custom information in the Summary tab.\fP
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.lonmin
|
||||
Default: \fB\-180\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdeg\fP
|
||||
.sp
|
||||
Minimum longitude of initially displayed map region.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.lonmax
|
||||
Default: \fB180\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdeg\fP
|
||||
.sp
|
||||
Maximum longitude of initially displayed map region.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.latmin
|
||||
Default: \fB\-90\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdeg\fP
|
||||
.sp
|
||||
Minimum latitude of initially displayed map region.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.latmax
|
||||
Default: \fB90\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdeg\fP
|
||||
.sp
|
||||
Maximum latitude of initially displayed map region.
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
\fBdisplay.event.*\fP
|
||||
\fIEvent information\fP
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.event.comment.id
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
ID of the event comment to be considered.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.event.comment.default
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Value to be shown in case no valid event comment is
|
||||
found.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.event.comment.label
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Label of the value to be shown.
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
\fBdisplay.origin.*\fP
|
||||
\fIOrigin information\fP
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
\fBdisplay.origin.comment.*\fP
|
||||
\fIDisplay origin comments.\fP
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.origin.comment.id
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
ID of the origin comment to be considered.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.origin.comment.default
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Value to be shown in case no valid origin comment is
|
||||
found.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B display.origin.comment.label
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Label of the value to be shown.
|
||||
.UNINDENT
|
||||
.sp
|
||||
\fBNOTE:\fP
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
\fBpoi.*\fP
|
||||
\fIDisplay information related to a point of interest (POI)\fP
|
||||
\fIread from the cities XML file.\fP
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B poi.maxDist
|
||||
Default: \fB20\fP
|
||||
.sp
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
Unit: \fIdeg\fP
|
||||
.sp
|
||||
Maximum distance in degrees of a POI to be taken into account.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B poi.minPopulation
|
||||
Type: \fIdouble\fP
|
||||
.sp
|
||||
The minimum population of a POI to be taken into account.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B poi.message
|
||||
Type: \fIstring\fP
|
||||
.sp
|
||||
Message conversion string that converts a POI into the text
|
||||
displayed under the region label. There are different
|
||||
placeholders that can be used: @dist@, @dir@, @poi@ and @region@.
|
||||
.UNINDENT
|
||||
.SH COMMAND-LINE OPTIONS
|
||||
.sp
|
||||
\fBscesv [options]\fP
|
||||
.SS Generic
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-h, \-\-help
|
||||
Show help message.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-V, \-\-version
|
||||
Show version information.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-config\-file arg
|
||||
Use alternative configuration file. When this option is
|
||||
used the loading of all stages is disabled. Only the
|
||||
given configuration file is parsed and used. To use
|
||||
another name for the configuration create a symbolic
|
||||
link of the application or copy it. Example:
|
||||
scautopick \-> scautopick2.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-plugins arg
|
||||
Load given plugins.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-auto\-shutdown arg
|
||||
Enable/disable self\-shutdown because a master module shutdown.
|
||||
This only works when messaging is enabled and the master
|
||||
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
||||
for the master module).
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-shutdown\-master\-module arg
|
||||
Set the name of the master\-module used for auto\-shutdown.
|
||||
This is the application name of the module actually
|
||||
started. If symlinks are used, then it is the name of
|
||||
the symlinked application.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-shutdown\-master\-username arg
|
||||
Set the name of the master\-username of the messaging
|
||||
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
|
||||
given as well, this parameter is ignored.
|
||||
.UNINDENT
|
||||
.SS Verbosity
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-verbosity arg
|
||||
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
||||
4:debug.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-v, \-\-v
|
||||
Increase verbosity level (may be repeated, eg. \-vv).
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-q, \-\-quiet
|
||||
Quiet mode: no logging output.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-component arg
|
||||
Limit the logging to a certain component. This option can
|
||||
be given more than once.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-s, \-\-syslog
|
||||
Use syslog logging backend. The output usually goes to
|
||||
/var/lib/messages.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-l, \-\-lockfile arg
|
||||
Path to lock file.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-console arg
|
||||
Send log output to stdout.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-debug
|
||||
Execute in debug mode.
|
||||
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-log\-file arg
|
||||
Use alternative log file.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-print\-component arg
|
||||
For each log entry print the component right after the
|
||||
log level. By default the component output is enabled
|
||||
for file output but disabled for console output.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-trace
|
||||
Execute in trace mode.
|
||||
Equivalent to \-\-verbosity=4 \-\-console=1 \-\-print\-component=1
|
||||
\-\-print\-context=1 .
|
||||
.UNINDENT
|
||||
.SS Messaging
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-u, \-\-user arg
|
||||
Overrides configuration parameter \fI\%connection.username\fP\&.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-H, \-\-host arg
|
||||
Overrides configuration parameter \fI\%connection.server\fP\&.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-t, \-\-timeout arg
|
||||
Overrides configuration parameter \fI\%connection.timeout\fP\&.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-g, \-\-primary\-group arg
|
||||
Overrides configuration parameter \fI\%connection.primaryGroup\fP\&.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-S, \-\-subscribe\-group arg
|
||||
A group to subscribe to.
|
||||
This option can be given more than once.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-content\-type arg
|
||||
Overrides configuration parameter \fI\%connection.contentType\fP\&.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-start\-stop\-msg arg
|
||||
Set sending of a start and a stop message.
|
||||
.UNINDENT
|
||||
.SS Database
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-db\-driver\-list
|
||||
List all supported database drivers.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-d, \-\-database arg
|
||||
The database connection string, format:
|
||||
\fI\%service://user:pwd@host/database\fP\&.
|
||||
\(dqservice\(dq is the name of the database driver which
|
||||
can be queried with \(dq\-\-db\-driver\-list\(dq.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-config\-module arg
|
||||
The config module to use.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-inventory\-db arg
|
||||
Load the inventory from the given database or file, format:
|
||||
[\fI\%service://]location\fP .
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-db\-disable
|
||||
Do not use the database at all
|
||||
.UNINDENT
|
||||
.SS Records
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-record\-driver\-list
|
||||
List all supported record stream drivers.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-I, \-\-record\-url arg
|
||||
The recordstream source URL, format:
|
||||
[\fI\%service://\fP]location[#type].
|
||||
\(dqservice\(dq is the name of the recordstream driver
|
||||
which can be queried with \(dq\-\-record\-driver\-list\(dq.
|
||||
If \(dqservice\(dq is not given, \(dq\fI\%file://\fP\(dq is
|
||||
used.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-record\-file arg
|
||||
Specify a file as record source.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-record\-type arg
|
||||
Specify a type for the records being read.
|
||||
.UNINDENT
|
||||
.SS Cities
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-city\-xml arg
|
||||
The path to the cities XML file. This overrides the default
|
||||
paths. Compare with the global parameter \(dqcitiesXML\(dq.
|
||||
.UNINDENT
|
||||
.SS User interface
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-F, \-\-full\-screen
|
||||
Start the application filling the entire screen.
|
||||
This only works with GUI applications.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-N, \-\-non\-interactive
|
||||
Use non\-interactive presentation mode. This only works with
|
||||
GUI applications.
|
||||
.UNINDENT
|
||||
.SS Options
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-script0 arg
|
||||
Path to the script called when configurable
|
||||
button0 is pressed; EventID, arrival count, magnitude and
|
||||
the additional location information string are passed as
|
||||
parameters $1, $2, $3 and $4, respectively.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-script1 arg
|
||||
Path to the script called when configurable
|
||||
button1 is pressed; EventID, arrival count, magnitude and
|
||||
the additional location information string are passed as
|
||||
parameters $1, $2, $3 and $4, respectively.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-load\-event\-db arg
|
||||
Number of days to load from database.
|
||||
.UNINDENT
|
||||
.SH AUTHOR
|
||||
gempa GmbH, GFZ Potsdam
|
||||
.SH COPYRIGHT
|
||||
gempa GmbH, GFZ Potsdam
|
||||
.\" Generated by docutils manpage writer.
|
||||
.
|
Reference in New Issue