[seiscomp, scanloc] Install, add .gitignore
This commit is contained in:
278
share/man/man1/import_inv.1
Normal file
278
share/man/man1/import_inv.1
Normal file
@ -0,0 +1,278 @@
|
||||
.\" Man page generated from reStructuredText.
|
||||
.
|
||||
.
|
||||
.nr rst2man-indent-level 0
|
||||
.
|
||||
.de1 rstReportMargin
|
||||
\\$1 \\n[an-margin]
|
||||
level \\n[rst2man-indent-level]
|
||||
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
-
|
||||
\\n[rst2man-indent0]
|
||||
\\n[rst2man-indent1]
|
||||
\\n[rst2man-indent2]
|
||||
..
|
||||
.de1 INDENT
|
||||
.\" .rstReportMargin pre:
|
||||
. RS \\$1
|
||||
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
|
||||
. nr rst2man-indent-level +1
|
||||
.\" .rstReportMargin post:
|
||||
..
|
||||
.de UNINDENT
|
||||
. RE
|
||||
.\" indent \\n[an-margin]
|
||||
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
.nr rst2man-indent-level -1
|
||||
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
|
||||
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
|
||||
..
|
||||
.TH "IMPORT_INV" "1" "Sep 22, 2025" "6.9.0" "SeisComP"
|
||||
.SH NAME
|
||||
import_inv \- SeisComP Documentation
|
||||
.sp
|
||||
\fBImport inventory information from various sources.\fP
|
||||
.SH DESCRIPTION
|
||||
.sp
|
||||
import_inv is a wrapper for inventory converters. Inventory converters convert
|
||||
an input format such as
|
||||
.TS
|
||||
center;
|
||||
|l|l|l|.
|
||||
_
|
||||
T{
|
||||
Format
|
||||
T} T{
|
||||
Converter
|
||||
T} T{
|
||||
Conversion
|
||||
T}
|
||||
_
|
||||
T{
|
||||
scml
|
||||
T} T{
|
||||
scml2inv
|
||||
T} T{
|
||||
\fI\%SeisComP inventory XML\fP, schema: \fB$SEISCOMP_ROOT/share/xml/\fP
|
||||
T}
|
||||
_
|
||||
T{
|
||||
sc3
|
||||
T} T{
|
||||
sc32inv
|
||||
T} T{
|
||||
Alias for scml for backwards compatibility to SeisComP3
|
||||
T}
|
||||
_
|
||||
T{
|
||||
arclink
|
||||
T} T{
|
||||
arclink2inv
|
||||
T} T{
|
||||
Arclink inventory XML
|
||||
T}
|
||||
_
|
||||
T{
|
||||
dlsv
|
||||
T} T{
|
||||
\fI\%dlsv2inv\fP
|
||||
T} T{
|
||||
\fI\%dataless SEED\fP
|
||||
T}
|
||||
_
|
||||
T{
|
||||
fdsnxml
|
||||
T} T{
|
||||
\fI\%fdsnxml2inv\fP
|
||||
T} T{
|
||||
\fI\%FDSN StationXML\fP
|
||||
T}
|
||||
_
|
||||
.TE
|
||||
.sp
|
||||
to SeisComP inventory XML which is read by the trunk config module to
|
||||
synchronize the local inventory file pool with the central inventory database.
|
||||
.sp
|
||||
For printing all available formats call
|
||||
.INDENT 0.0
|
||||
.INDENT 3.5
|
||||
.sp
|
||||
.nf
|
||||
.ft C
|
||||
$ import_inv help formats
|
||||
.ft P
|
||||
.fi
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.sp
|
||||
When \fBimport_inv help formats\fP is called it globs for
|
||||
\fB$SEISCOMP_ROOT/bin/*2inv\fP\&.
|
||||
If another format needs to be converted, it is very easy to provide a new
|
||||
converter.
|
||||
.SS Converter interface
|
||||
.sp
|
||||
For making a new converter work with import_inv it must implement an interface
|
||||
on shell level. Furthermore the converter program must be named
|
||||
\fIformat\fP\fB2inv\fP and must live in \fBSEISCOMP_ROOT/bin\fP\&.
|
||||
.sp
|
||||
The converter program must take the input location (file, directory, URL, ...)
|
||||
as first parameter and the output file (SeisComP XML) as second parameter. The
|
||||
output file must be optional and default to stdout.
|
||||
.sp
|
||||
To add a new converter for a new format, e.g. Excel, place the new converter
|
||||
program at \fB$SEISCOMP_ROOT/bin/excel2inv\fP\&.
|
||||
.SS Examples
|
||||
.INDENT 0.0
|
||||
.IP \(bu 2
|
||||
Convert inventory file in FDSN StationXML format (fdsnxml) and copy the content to
|
||||
\fB$SEISCOMP_ROOT/etc/inventoy/inventory.xml\fP\&. The call will invoke
|
||||
\fI\%fdsnxml2inv\fP for actually making the conversion:
|
||||
.INDENT 2.0
|
||||
.INDENT 3.5
|
||||
.sp
|
||||
.nf
|
||||
.ft C
|
||||
$ import_inv fdsnxml inventory_fdsn.xml $SEISCOMP_ROOT/etc/inventoy/inventory.xml
|
||||
.ft P
|
||||
.fi
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.UNINDENT
|
||||
.SH MODULE CONFIGURATION
|
||||
.nf
|
||||
\fBetc/defaults/global.cfg\fP
|
||||
\fBetc/defaults/import_inv.cfg\fP
|
||||
\fBetc/global.cfg\fP
|
||||
\fBetc/import_inv.cfg\fP
|
||||
\fB~/.seiscomp/global.cfg\fP
|
||||
\fB~/.seiscomp/import_inv.cfg\fP
|
||||
.fi
|
||||
.sp
|
||||
.sp
|
||||
import_inv inherits \fI\%global options\fP\&.
|
||||
.SH COMMAND-LINE OPTIONS
|
||||
.sp
|
||||
\fBimport_inv [FORMAT] input [output]\fP
|
||||
.sp
|
||||
\fBimport_inv help [topic]\fP
|
||||
.sp
|
||||
The first form takes the format as first parameter and the input
|
||||
and output location. The input location is either a file or directory
|
||||
depending on the format and its converter. If the output is not
|
||||
given it defaults to seiscomp/etc/inventory/{input}.xml. To write
|
||||
the output to stdout, \(dq\-\(dq must be used.
|
||||
.sp
|
||||
The second form provides help on a particular topic. The only topic
|
||||
currently supported is \(dqformats\(dq which prints all available input
|
||||
formats.
|
||||
.SS Generic
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-h, \-\-help
|
||||
Show help message.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-V, \-\-version
|
||||
Show version information.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-config\-file arg
|
||||
Use alternative configuration file. When this option is
|
||||
used the loading of all stages is disabled. Only the
|
||||
given configuration file is parsed and used. To use
|
||||
another name for the configuration create a symbolic
|
||||
link of the application or copy it. Example:
|
||||
scautopick \-> scautopick2.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-plugins arg
|
||||
Load given plugins.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-D, \-\-daemon
|
||||
Run as daemon. This means the application will fork itself
|
||||
and doesn\(aqt need to be started with &.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-auto\-shutdown arg
|
||||
Enable/disable self\-shutdown because a master module shutdown.
|
||||
This only works when messaging is enabled and the master
|
||||
module sends a shutdown message (enabled with \-\-start\-stop\-msg
|
||||
for the master module).
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-shutdown\-master\-module arg
|
||||
Set the name of the master\-module used for auto\-shutdown.
|
||||
This is the application name of the module actually
|
||||
started. If symlinks are used, then it is the name of
|
||||
the symlinked application.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-shutdown\-master\-username arg
|
||||
Set the name of the master\-username of the messaging
|
||||
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
|
||||
given as well, this parameter is ignored.
|
||||
.UNINDENT
|
||||
.SS Verbosity
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-verbosity arg
|
||||
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
|
||||
4:debug.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-v, \-\-v
|
||||
Increase verbosity level (may be repeated, eg. \-vv).
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-q, \-\-quiet
|
||||
Quiet mode: no logging output.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-component arg
|
||||
Limit the logging to a certain component. This option can
|
||||
be given more than once.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-s, \-\-syslog
|
||||
Use syslog logging backend. The output usually goes to
|
||||
/var/lib/messages.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-l, \-\-lockfile arg
|
||||
Path to lock file.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-console arg
|
||||
Send log output to stdout.
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-debug
|
||||
Execute in debug mode.
|
||||
Equivalent to \-\-verbosity=4 \-\-console=1 .
|
||||
.UNINDENT
|
||||
.INDENT 0.0
|
||||
.TP
|
||||
.B \-\-log\-file arg
|
||||
Use alternative log file.
|
||||
.UNINDENT
|
||||
.SH AUTHOR
|
||||
gempa GmbH, GFZ Potsdam
|
||||
.SH COPYRIGHT
|
||||
gempa GmbH, GFZ Potsdam
|
||||
.\" Generated by docutils manpage writer.
|
||||
.
|
Reference in New Issue
Block a user