495 lines
		
	
	
		
			10 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
			
		
		
	
	
			495 lines
		
	
	
		
			10 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
.\" Man page generated from reStructuredText.
 | 
						|
.
 | 
						|
.
 | 
						|
.nr rst2man-indent-level 0
 | 
						|
.
 | 
						|
.de1 rstReportMargin
 | 
						|
\\$1 \\n[an-margin]
 | 
						|
level \\n[rst2man-indent-level]
 | 
						|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
-
 | 
						|
\\n[rst2man-indent0]
 | 
						|
\\n[rst2man-indent1]
 | 
						|
\\n[rst2man-indent2]
 | 
						|
..
 | 
						|
.de1 INDENT
 | 
						|
.\" .rstReportMargin pre:
 | 
						|
. RS \\$1
 | 
						|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
 | 
						|
. nr rst2man-indent-level +1
 | 
						|
.\" .rstReportMargin post:
 | 
						|
..
 | 
						|
.de UNINDENT
 | 
						|
. RE
 | 
						|
.\" indent \\n[an-margin]
 | 
						|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.nr rst2man-indent-level -1
 | 
						|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
 | 
						|
..
 | 
						|
.TH "SH2PROC" "1" "Oct 14, 2025" "6.9.1" "SeisComP"
 | 
						|
.SH NAME
 | 
						|
sh2proc \- SeisComP Documentation
 | 
						|
.sp
 | 
						|
\fBConvert SeismicHandler event files to SCML.\fP
 | 
						|
.SH DESCRIPTION
 | 
						|
.sp
 | 
						|
sh2proc converts \fI\%Seismic Handler\fP event data to
 | 
						|
SeisComP XML format. Data is read from input file or \fIstdin\fP if no input file is
 | 
						|
specified.  The result is available on \fIstdout\fP\&.
 | 
						|
.SH CODE MAPPING
 | 
						|
.sp
 | 
						|
Since Seismic Handler only specifies station and component codes, a mapping to
 | 
						|
SeisComP network, location and channel codes is necessary. The script assumes
 | 
						|
that the same station code is not used in different networks. In case an
 | 
						|
ambiguous id is found a warning is printed and the first network code is used.
 | 
						|
The channel and stream code is extracted from the dectecStream and detecLocid
 | 
						|
configured in the global bindings. In case no configuration module is available
 | 
						|
the first location and stream is used.
 | 
						|
.SH EVENT PARAMETERS
 | 
						|
.INDENT 0.0
 | 
						|
.IP \(bu 2
 | 
						|
Event types given in Seismic Handler files are mapped to SeisComP event types:
 | 
						|
.TS
 | 
						|
center;
 | 
						|
|l|l|.
 | 
						|
_
 | 
						|
T{
 | 
						|
Seismic Handler
 | 
						|
T}	T{
 | 
						|
SeisComP
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
teleseismic quake
 | 
						|
T}	T{
 | 
						|
earthquake
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
regional quake
 | 
						|
T}	T{
 | 
						|
earthquake
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
local quake
 | 
						|
T}	T{
 | 
						|
earthquake
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
quarry blast
 | 
						|
T}	T{
 | 
						|
quarry blast
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
nuclear explosion
 | 
						|
T}	T{
 | 
						|
nuclear explosion
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
mining event
 | 
						|
T}	T{
 | 
						|
mining explosion
 | 
						|
T}
 | 
						|
_
 | 
						|
.TE
 | 
						|
.IP \(bu 2
 | 
						|
The EventID given in Seismic Handler files is mapped as a comment to the event.
 | 
						|
.UNINDENT
 | 
						|
.SH MAGNITUDES
 | 
						|
.INDENT 0.0
 | 
						|
.IP \(bu 2
 | 
						|
Magnitude types given in Seismic Handler files are mapped to SeisComP magnitudes:
 | 
						|
.TS
 | 
						|
center;
 | 
						|
|l|l|.
 | 
						|
_
 | 
						|
T{
 | 
						|
Seismic Handler
 | 
						|
T}	T{
 | 
						|
SeisComP
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
m
 | 
						|
T}	T{
 | 
						|
M
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
ml
 | 
						|
T}	T{
 | 
						|
ML
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
mb
 | 
						|
T}	T{
 | 
						|
mb
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
ms
 | 
						|
T}	T{
 | 
						|
Ms(BB)
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
mw
 | 
						|
T}	T{
 | 
						|
Mw
 | 
						|
T}
 | 
						|
_
 | 
						|
T{
 | 
						|
bb
 | 
						|
T}	T{
 | 
						|
mB
 | 
						|
T}
 | 
						|
_
 | 
						|
.TE
 | 
						|
.IP \(bu 2
 | 
						|
ML magnitudes in Seismic Handler files have no corresponding measured amplitudes.
 | 
						|
Therefore the ML station magnitudes are converted without referencing the amplitude.
 | 
						|
.IP \(bu 2
 | 
						|
Seismic Handler uses the phase name \(dqL\(dq for referring to surface waves without
 | 
						|
further specification. The phase name is kept unchanged.
 | 
						|
.UNINDENT
 | 
						|
.SH DISTANCE CALCULATIONS
 | 
						|
.sp
 | 
						|
In Seismic Handler files distances can be given in units of km or degree but in
 | 
						|
SeisComP only degree is used. Both representations are considered for conversion.
 | 
						|
In case of double posting preference is given to the Seismic Handler values given in km
 | 
						|
due to their higher precision.
 | 
						|
.SH BEAM PARAMETERS
 | 
						|
.sp
 | 
						|
Seismic Handler files provide the phase picks with theoretical, measured and corrected
 | 
						|
slowness and (back) azimuth but the pick in SeisComP knows only one value.
 | 
						|
During conversion highest preference is given to corrected values.
 | 
						|
The theoretical values are ignored.
 | 
						|
.SH LIMITATIONS
 | 
						|
.sp
 | 
						|
The following parameters from Seismic Handler files are not considered:
 | 
						|
.INDENT 0.0
 | 
						|
.IP \(bu 2
 | 
						|
Phase Flag
 | 
						|
.IP \(bu 2
 | 
						|
Location Input Params
 | 
						|
.IP \(bu 2
 | 
						|
Reference Location Name
 | 
						|
.IP \(bu 2
 | 
						|
Quality Number
 | 
						|
.IP \(bu 2
 | 
						|
Ampl&Period Source
 | 
						|
.IP \(bu 2
 | 
						|
Location Quality
 | 
						|
.IP \(bu 2
 | 
						|
Reference Latitude
 | 
						|
.IP \(bu 2
 | 
						|
Reference Longitude
 | 
						|
.IP \(bu 2
 | 
						|
Amplitude Time
 | 
						|
.UNINDENT
 | 
						|
.SH FURTHER PROCESSING IN SEISCOMP
 | 
						|
.sp
 | 
						|
The created XML files can be used in multiple ways, e.g.:
 | 
						|
.INDENT 0.0
 | 
						|
.IP 1. 3
 | 
						|
By other modules in an XML\-base playback
 | 
						|
.IP 2. 3
 | 
						|
Inject into the messaging system by \fI\%scdispatch\fP
 | 
						|
.IP 3. 3
 | 
						|
Integrate into the database by \fI\%scdb\fP
 | 
						|
.UNINDENT
 | 
						|
.SH EXAMPLES
 | 
						|
.INDENT 0.0
 | 
						|
.IP 1. 3
 | 
						|
Convert the Seismic Handler file \fIshm.evt\fP and writes SCML into the file
 | 
						|
\fIsc.xml\fP\&. The database connection to read inventory and configuration
 | 
						|
information is fetched from the default messaging connection.
 | 
						|
.INDENT 3.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
sh2proc shm.evt > sc.xml
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.IP 2. 3
 | 
						|
Read Seismic Handler data from \fIstdin\fP\&. Inventory and configuration information
 | 
						|
is provided through files.
 | 
						|
.INDENT 3.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
cat shm.evt | sh2proc \-\-inventory\-db=inventory.xml \-\-config\-db=config.xml > sc.xml
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SH SHM.EVT FILE FORMAT
 | 
						|
.sp
 | 
						|
The list of parameters supported by sh2proc may be incomplete.
 | 
						|
Read the original \fI\%format and parameter description\fP
 | 
						|
of the SeismicHandler .evt files for providing correct input files.
 | 
						|
.sp
 | 
						|
Example of a SeismicHandler \fIshm.evt\fP file with supported parameters:
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
Event ID               : 1170102002
 | 
						|
Station code           : VITZ
 | 
						|
Onset time             : 2\-JAN\-2017_12:25:40.415
 | 
						|
Onset type             : emergent
 | 
						|
Phase name             : Pg
 | 
						|
Event Type             : mining event
 | 
						|
Applied filter         : SHM_BP_1HZ_25HZ_3
 | 
						|
Component              : Z
 | 
						|
Quality number         : 2
 | 
						|
Pick Type              : manual
 | 
						|
Weight                 : 4
 | 
						|
Theo. Azimuth (deg)    :   27.29
 | 
						|
Theo. Backazimuth (deg):  207.36
 | 
						|
Distance (deg)         :  0.122
 | 
						|
Distance (km)          : 13.572
 | 
						|
Magnitude ml           : 1.0
 | 
						|
Phase Flags            : L
 | 
						|
\-\-\- End of Phase \-\-\-
 | 
						|
 | 
						|
 | 
						|
Event ID               : 1170102002
 | 
						|
Station code           : WESF
 | 
						|
Onset time             : 2\-JAN\-2017_12:25:53.714
 | 
						|
Onset type             : emergent
 | 
						|
Phase name             : Pg
 | 
						|
Event Type             : mining event
 | 
						|
Applied filter         : SHM_BP_1HZ_25HZ_3
 | 
						|
Component              : Z
 | 
						|
Quality number         : 2
 | 
						|
Pick Type              : manual
 | 
						|
Weight                 : 4
 | 
						|
Theo. Azimuth (deg)    :  106.98
 | 
						|
Theo. Backazimuth (deg):  287.91
 | 
						|
Distance (deg)         :  0.807
 | 
						|
Distance (km)          : 89.708
 | 
						|
Magnitude ml           : 1.8
 | 
						|
Mean Magnitude ml      : 1.1
 | 
						|
Latitude               : +50.779
 | 
						|
Longitude              :  +10.003
 | 
						|
Depth (km)             :   0.0
 | 
						|
Depth type             : (g) estimated
 | 
						|
Origin time            :  2\-JAN\-2017_12:25:38.273
 | 
						|
Region Table           : GEO_REG
 | 
						|
Region ID              : 5326
 | 
						|
Source region          : Tann, E of Fulda
 | 
						|
Velocity Model         : deu
 | 
						|
Location Input Params  : 20
 | 
						|
Reference Location Name: CENTRE
 | 
						|
\-\-\- End of Phase \-\-\-
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SH MODULE CONFIGURATION
 | 
						|
.nf
 | 
						|
\fBetc/defaults/global.cfg\fP
 | 
						|
\fBetc/defaults/sh2proc.cfg\fP
 | 
						|
\fBetc/global.cfg\fP
 | 
						|
\fBetc/sh2proc.cfg\fP
 | 
						|
\fB~/.seiscomp/global.cfg\fP
 | 
						|
\fB~/.seiscomp/sh2proc.cfg\fP
 | 
						|
.fi
 | 
						|
.sp
 | 
						|
.sp
 | 
						|
sh2proc inherits \fI\%global options\fP\&.
 | 
						|
.SH COMMAND-LINE OPTIONS
 | 
						|
.sp
 | 
						|
\fBsh2proc [options]\fP
 | 
						|
.SS Generic
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-h, \-\-help
 | 
						|
Show help message.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-V, \-\-version
 | 
						|
Show version information.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-file arg
 | 
						|
Use alternative configuration file. When this option is
 | 
						|
used the loading of all stages is disabled. Only the
 | 
						|
given configuration file is parsed and used. To use
 | 
						|
another name for the configuration create a symbolic
 | 
						|
link of the application or copy it. Example:
 | 
						|
scautopick \-> scautopick2.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-plugins arg
 | 
						|
Load given plugins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-D, \-\-daemon
 | 
						|
Run as daemon. This means the application will fork itself
 | 
						|
and doesn\(aqt need to be started with &.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-auto\-shutdown arg
 | 
						|
Enable/disable self\-shutdown because a master module shutdown.
 | 
						|
This only works when messaging is enabled and the master
 | 
						|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
 | 
						|
for the master module).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-module arg
 | 
						|
Set the name of the master\-module used for auto\-shutdown.
 | 
						|
This is the application name of the module actually
 | 
						|
started. If symlinks are used, then it is the name of
 | 
						|
the symlinked application.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-username arg
 | 
						|
Set the name of the master\-username of the messaging
 | 
						|
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
 | 
						|
given as well, this parameter is ignored.
 | 
						|
.UNINDENT
 | 
						|
.SS Verbosity
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-verbosity arg
 | 
						|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
 | 
						|
4:debug.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-v, \-\-v
 | 
						|
Increase verbosity level (may be repeated, eg. \-vv).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-q, \-\-quiet
 | 
						|
Quiet mode: no logging output.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-component arg
 | 
						|
Limit the logging to a certain component. This option can
 | 
						|
be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-s, \-\-syslog
 | 
						|
Use syslog logging backend. The output usually goes to
 | 
						|
/var/lib/messages.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-l, \-\-lockfile arg
 | 
						|
Path to lock file.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-console arg
 | 
						|
Send log output to stdout.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-debug
 | 
						|
Execute in debug mode.
 | 
						|
Equivalent to \-\-verbosity=4 \-\-console=1 .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-log\-file arg
 | 
						|
Use alternative log file.
 | 
						|
.UNINDENT
 | 
						|
.SS Messaging
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-u, \-\-user arg
 | 
						|
Overrides configuration parameter \fI\%connection.username\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-H, \-\-host arg
 | 
						|
Overrides configuration parameter \fI\%connection.server\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-t, \-\-timeout arg
 | 
						|
Overrides configuration parameter \fI\%connection.timeout\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-g, \-\-primary\-group arg
 | 
						|
Overrides configuration parameter \fI\%connection.primaryGroup\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-S, \-\-subscribe\-group arg
 | 
						|
A group to subscribe to.
 | 
						|
This option can be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-content\-type arg
 | 
						|
Overrides configuration parameter \fI\%connection.contentType\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-start\-stop\-msg arg
 | 
						|
Set sending of a start and a stop message.
 | 
						|
.UNINDENT
 | 
						|
.SS Database
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-db\-driver\-list
 | 
						|
List all supported database drivers.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-d, \-\-database arg
 | 
						|
The database connection string, format:
 | 
						|
\fI\%service://user:pwd@host/database\fP\&.
 | 
						|
\(dqservice\(dq is the name of the database driver which
 | 
						|
can be queried with \(dq\-\-db\-driver\-list\(dq.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-module arg
 | 
						|
The config module to use.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-inventory\-db arg
 | 
						|
Load the inventory from the given database or file, format:
 | 
						|
[\fI\%service://]location\fP .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-db\-disable
 | 
						|
Do not use the database at all
 | 
						|
.UNINDENT
 | 
						|
.SH AUTHOR
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.SH COPYRIGHT
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.\" Generated by docutils manpage writer.
 | 
						|
.
 |