504 lines
		
	
	
		
			11 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
			
		
		
	
	
			504 lines
		
	
	
		
			11 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
.\" Man page generated from reStructuredText.
 | 
						|
.
 | 
						|
.
 | 
						|
.nr rst2man-indent-level 0
 | 
						|
.
 | 
						|
.de1 rstReportMargin
 | 
						|
\\$1 \\n[an-margin]
 | 
						|
level \\n[rst2man-indent-level]
 | 
						|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
-
 | 
						|
\\n[rst2man-indent0]
 | 
						|
\\n[rst2man-indent1]
 | 
						|
\\n[rst2man-indent2]
 | 
						|
..
 | 
						|
.de1 INDENT
 | 
						|
.\" .rstReportMargin pre:
 | 
						|
. RS \\$1
 | 
						|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
 | 
						|
. nr rst2man-indent-level +1
 | 
						|
.\" .rstReportMargin post:
 | 
						|
..
 | 
						|
.de UNINDENT
 | 
						|
. RE
 | 
						|
.\" indent \\n[an-margin]
 | 
						|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.nr rst2man-indent-level -1
 | 
						|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
 | 
						|
..
 | 
						|
.TH "SCXMLDUMP" "1" "Oct 14, 2025" "6.9.1" "SeisComP"
 | 
						|
.SH NAME
 | 
						|
scxmldump \- SeisComP Documentation
 | 
						|
.sp
 | 
						|
\fBDump database objects to XML files.\fP
 | 
						|
.SH DESCRIPTION
 | 
						|
.sp
 | 
						|
scxmldump reads various parameters from a SeisComP database:
 | 
						|
.INDENT 0.0
 | 
						|
.IP \(bu 2
 | 
						|
Availability,
 | 
						|
.IP \(bu 2
 | 
						|
Config (bindings parameters),
 | 
						|
.IP \(bu 2
 | 
						|
Event parameters,
 | 
						|
.IP \(bu 2
 | 
						|
Inventory,
 | 
						|
.IP \(bu 2
 | 
						|
Journal,
 | 
						|
.IP \(bu 2
 | 
						|
Routing.
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
The parameters are sent to stdout or written into an XML (\fI\%SCML\fP) file.
 | 
						|
.sp
 | 
						|
\fBNOTE:\fP
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
Waveform quality control (QC) parameters can be read from databases using
 | 
						|
scqcquery\&.
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SS Event parameters
 | 
						|
.sp
 | 
						|
To get event, origin or pick information from the database without using SQL
 | 
						|
commands is an important task for the user. \fI\%scxmldump\fP queries the
 | 
						|
database and transforms that information into XML. Events and origins can be
 | 
						|
treated further by \fI\%scbulletin\fP for generating bulletins or conversion
 | 
						|
into KML.
 | 
						|
.sp
 | 
						|
Many processing modules, e.g., \fI\%scevent\fP support the on\-demand processing
 | 
						|
of dumped event parameters by the command\-line option \fB\-\-ep\fP\&.
 | 
						|
Importing event parameters into another database is possible with \fI\%scdb\fP
 | 
						|
and sending to a SeisComP messaging is provided by \fI\%scdispatch\fP\&.
 | 
						|
.sp
 | 
						|
\fBHINT:\fP
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
Events, origins and picks are referred to by their public IDs. IDs of events
 | 
						|
and origins can be provided by \fI\%scevtls\fP and \fI\%scorgls\fP,
 | 
						|
respectively. Event, origin and pick IDs can also be read from graphical
 | 
						|
tools like \fI\%scolv\fP or used database queries assisted by \fI\%scquery\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SS Format conversion
 | 
						|
.sp
 | 
						|
Conversion of \fI\%SCML\fP into other formats is supported by \fI\%sccnv\fP\&.
 | 
						|
An XSD schema of the XML output can be found under
 | 
						|
\fB$SEISCOMP_ROOT/share/xml/\fP\&.
 | 
						|
.SS Examples
 | 
						|
.sp
 | 
						|
Dump inventory
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fI \-o inventory.xml \-d mysql://sysop:sysop@localhost/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Dump config (bindings parameters)
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fC \-o config.xml \-d mysql://sysop:sysop@localhost/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Dump full event data incl. the relevant journal entries
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fPAMFJ \-E test2012abcd \-o test2012abcd.xml \e
 | 
						|
          \-d mysql://sysop:sysop@localhost/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Dump summary event data
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fap \-E test2012abcd \-o test2012abcd.xml \e
 | 
						|
          \-d mysql://sysop:sysop@localhost/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Create bulletin from an event
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fPAMF \-E test2012abcd
 | 
						|
          \-d mysql://sysop:sysop@localhost/seiscomp | \e
 | 
						|
scbulletin
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Copy event parameters to another database
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fPAMF \-E test2012abcd \e
 | 
						|
          \-d mysql://sysop:sysop@localhost/seiscomp | \e
 | 
						|
scdb \-i \- \-d mysql://sysop:sysop@archive\-db/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.sp
 | 
						|
Export the entire journal:
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
scxmldump \-fJ \-o journal.xml \e
 | 
						|
          \-d mysql://sysop:sysop@localhost/seiscomp
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SH MODULE CONFIGURATION
 | 
						|
.nf
 | 
						|
\fBetc/defaults/global.cfg\fP
 | 
						|
\fBetc/defaults/scxmldump.cfg\fP
 | 
						|
\fBetc/global.cfg\fP
 | 
						|
\fBetc/scxmldump.cfg\fP
 | 
						|
\fB~/.seiscomp/global.cfg\fP
 | 
						|
\fB~/.seiscomp/scxmldump.cfg\fP
 | 
						|
.fi
 | 
						|
.sp
 | 
						|
.sp
 | 
						|
scxmldump inherits \fI\%global options\fP\&.
 | 
						|
.SH COMMAND-LINE OPTIONS
 | 
						|
.sp
 | 
						|
\fBscxmldump [options]\fP
 | 
						|
.SS Generic
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-h, \-\-help
 | 
						|
Show help message.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-V, \-\-version
 | 
						|
Show version information.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-file arg
 | 
						|
Use alternative configuration file. When this option is
 | 
						|
used the loading of all stages is disabled. Only the
 | 
						|
given configuration file is parsed and used. To use
 | 
						|
another name for the configuration create a symbolic
 | 
						|
link of the application or copy it. Example:
 | 
						|
scautopick \-> scautopick2.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-plugins arg
 | 
						|
Load given plugins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-D, \-\-daemon
 | 
						|
Run as daemon. This means the application will fork itself
 | 
						|
and doesn\(aqt need to be started with &.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-auto\-shutdown arg
 | 
						|
Enable/disable self\-shutdown because a master module shutdown.
 | 
						|
This only works when messaging is enabled and the master
 | 
						|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
 | 
						|
for the master module).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-module arg
 | 
						|
Set the name of the master\-module used for auto\-shutdown.
 | 
						|
This is the application name of the module actually
 | 
						|
started. If symlinks are used, then it is the name of
 | 
						|
the symlinked application.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-username arg
 | 
						|
Set the name of the master\-username of the messaging
 | 
						|
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
 | 
						|
given as well, this parameter is ignored.
 | 
						|
.UNINDENT
 | 
						|
.SS Verbosity
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-verbosity arg
 | 
						|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
 | 
						|
4:debug.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-v, \-\-v
 | 
						|
Increase verbosity level (may be repeated, eg. \-vv).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-q, \-\-quiet
 | 
						|
Quiet mode: no logging output.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-component arg
 | 
						|
Limit the logging to a certain component. This option can
 | 
						|
be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-s, \-\-syslog
 | 
						|
Use syslog logging backend. The output usually goes to
 | 
						|
/var/lib/messages.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-l, \-\-lockfile arg
 | 
						|
Path to lock file.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-console arg
 | 
						|
Send log output to stdout.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-debug
 | 
						|
Execute in debug mode.
 | 
						|
Equivalent to \-\-verbosity=4 \-\-console=1 .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-log\-file arg
 | 
						|
Use alternative log file.
 | 
						|
.UNINDENT
 | 
						|
.SS Messaging
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-u, \-\-user arg
 | 
						|
Overrides configuration parameter \fI\%connection.username\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-H, \-\-host arg
 | 
						|
Overrides configuration parameter \fI\%connection.server\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-t, \-\-timeout arg
 | 
						|
Overrides configuration parameter \fI\%connection.timeout\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-g, \-\-primary\-group arg
 | 
						|
Overrides configuration parameter \fI\%connection.primaryGroup\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-S, \-\-subscribe\-group arg
 | 
						|
A group to subscribe to.
 | 
						|
This option can be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-content\-type arg
 | 
						|
Overrides configuration parameter \fI\%connection.contentType\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-start\-stop\-msg arg
 | 
						|
Set sending of a start and a stop message.
 | 
						|
.UNINDENT
 | 
						|
.SS Database
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-db\-driver\-list
 | 
						|
List all supported database drivers.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-d, \-\-database arg
 | 
						|
The database connection string, format:
 | 
						|
\fI\%service://user:pwd@host/database\fP\&.
 | 
						|
\(dqservice\(dq is the name of the database driver which
 | 
						|
can be queried with \(dq\-\-db\-driver\-list\(dq.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-module arg
 | 
						|
The config module to use.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-inventory\-db arg
 | 
						|
Load the inventory from the given database or file, format:
 | 
						|
[\fI\%service://]location\fP .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-db arg
 | 
						|
Load the configuration from the given database or file,
 | 
						|
format: [\fI\%service://]location\fP .
 | 
						|
.UNINDENT
 | 
						|
.SS Dump
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-listen
 | 
						|
Enable server mode which listens to the message server for
 | 
						|
incoming events and dumps each received add/update.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-I, \-\-inventory
 | 
						|
Dump the inventory.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-without\-station\-groups
 | 
						|
Remove all station groups from inventory.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-stations sta\-list
 | 
						|
If inventory is exported, filter the stations to export.
 | 
						|
Wildcards are supported. Format of each item: net[.{sta|*}].
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-C, \-\-config
 | 
						|
Dump the configuration (bindings).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-J, \-\-journal
 | 
						|
Dump the journal. In combination with \-E only corresponding
 | 
						|
journal entries are included.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-R, \-\-routing
 | 
						|
Dump the routing.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-Y, \-\-availability
 | 
						|
Dump data availability information.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-with\-segments
 | 
						|
Dump individual data segments.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-pick ID
 | 
						|
Pick public ID(s) to dump. Multiple IDs may be specified
 | 
						|
as a comma\-separated list.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-O, \-\-origin ID
 | 
						|
Origin public ID(s) to dump. Multiple origins may be specified
 | 
						|
as a comma\-separated list.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-E, \-\-event ID
 | 
						|
Event public ID(s) to dump. Multiple events may be specified
 | 
						|
as a comma\-separated list.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-P, \-\-with\-picks
 | 
						|
Add picks associated to origins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-A, \-\-with\-amplitudes
 | 
						|
Add amplitudes associated to magnitudes.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-M, \-\-with\-magnitudes
 | 
						|
Add station magnitudes associated to origins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-F, \-\-with\-focal\-mechanism
 | 
						|
Add focal mechanisms associated to events.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-a, \-\-ignore\-arrivals
 | 
						|
Do not dump arrivals part of origins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-ignore\-magnitudes
 | 
						|
Do not export (network) magnitudes of origins. This
 | 
						|
option is most useful in combination with \-O to only
 | 
						|
export the location information.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-p, \-\-preferred\-only
 | 
						|
When exporting events only the preferred origin, the preferred
 | 
						|
magnitude and the preferred focal mechanism will be dumped.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-m, \-\-all\-magnitudes
 | 
						|
If only the preferred origin is exported, all magnitudes for
 | 
						|
this origin will be dumped.
 | 
						|
.UNINDENT
 | 
						|
.SS Output
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-f, \-\-formatted
 | 
						|
Use formatted XML output. Otherwise all XML is printed
 | 
						|
on one line.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-o, \-\-output
 | 
						|
Name of output file. If not given, output is sent to
 | 
						|
stdout.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-prepend\-datasize
 | 
						|
Prepend a line with the length of the XML data.
 | 
						|
.UNINDENT
 | 
						|
.SH AUTHOR
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.SH COPYRIGHT
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.\" Generated by docutils manpage writer.
 | 
						|
.
 |