522 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
			
		
		
	
	
			522 lines
		
	
	
		
			13 KiB
		
	
	
	
		
			Groff
		
	
	
	
	
	
.\" Man page generated from reStructuredText.
 | 
						|
.
 | 
						|
.
 | 
						|
.nr rst2man-indent-level 0
 | 
						|
.
 | 
						|
.de1 rstReportMargin
 | 
						|
\\$1 \\n[an-margin]
 | 
						|
level \\n[rst2man-indent-level]
 | 
						|
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
-
 | 
						|
\\n[rst2man-indent0]
 | 
						|
\\n[rst2man-indent1]
 | 
						|
\\n[rst2man-indent2]
 | 
						|
..
 | 
						|
.de1 INDENT
 | 
						|
.\" .rstReportMargin pre:
 | 
						|
. RS \\$1
 | 
						|
. nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
 | 
						|
. nr rst2man-indent-level +1
 | 
						|
.\" .rstReportMargin post:
 | 
						|
..
 | 
						|
.de UNINDENT
 | 
						|
. RE
 | 
						|
.\" indent \\n[an-margin]
 | 
						|
.\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.nr rst2man-indent-level -1
 | 
						|
.\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
 | 
						|
.in \\n[rst2man-indent\\n[rst2man-indent-level]]u
 | 
						|
..
 | 
						|
.TH "SCAMP" "1" "Oct 14, 2025" "6.9.1" "SeisComP"
 | 
						|
.SH NAME
 | 
						|
scamp \- SeisComP Documentation
 | 
						|
.sp
 | 
						|
\fBCalculates amplitudes on basis of incoming origins and the associated picks.\fP
 | 
						|
.SH DESCRIPTION
 | 
						|
.sp
 | 
						|
scamp measures several different kinds of amplitudes from waveform data.
 | 
						|
It listens for origins and measures amplitudes in time windows determined
 | 
						|
from the origin. Thus, in contrast to amplitudes measured by \fI\%scautopick\fP
 | 
						|
the considered time windows can depend on epicentral distance.
 | 
						|
The resulting amplitude objects are sent to the \(dqAMPLITUDE\(dq
 | 
						|
messaging group. scamp is the counterpart of \fI\%scmag\fP\&. Usually, all
 | 
						|
amplitudes are computed at once by scamp and then published.
 | 
						|
Only very rarely an amplitude needs to be recomputed if the location of an
 | 
						|
origin changes significantly. The amplitude can be reused by \fI\%scmag\fP, making
 | 
						|
magnitude computation and update efficient. Currently, the automatic picker
 | 
						|
in SeisComP, scautopick, also measures a small set of amplitudes
 | 
						|
(namely \(dqsnr\(dq and \(dqmb\(dq, the signal\-to\-noise ratio and the amplitude used in
 | 
						|
mb magnitude computation, respectively) for each automatic pick in fixed
 | 
						|
time windows. If there already exists an amplitude, e.g. a previously determined
 | 
						|
one by scautopick, scamp will not measure it again for the respective stream.
 | 
						|
.sp
 | 
						|
Amplitudes are also needed, however, for manual picks. scamp does this as well.
 | 
						|
Arrivals with weight smaller than 0.5 (default) in the corresponding Origin are
 | 
						|
discarded. This minimum weight can be configured with
 | 
						|
\fI\%amptool.minimumPickWeight\fP\&.
 | 
						|
.SH AMPLITUDE TYPES
 | 
						|
.sp
 | 
						|
Amplitudes of many types are currently computed for their corresponding
 | 
						|
magnitudes.
 | 
						|
.sp
 | 
						|
\fBNOTE:\fP
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
In order to be used by scmag, the input amplitude names for the
 | 
						|
various magnitude types must typically match exactly. Exceptions:
 | 
						|
.INDENT 0.0
 | 
						|
.IP \(bu 2
 | 
						|
\fI\%MN\fP requires \fIAMN\fP amplitudes,
 | 
						|
.IP \(bu 2
 | 
						|
\fI\%MLr\fP requires \fIMLv\fP amplitudes.
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SS Local distances
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \fI\%Md\fP
 | 
						|
Duration magnitude as described in HYPOINVERSE (Klein [\fI\%50\fP]).
 | 
						|
.TP
 | 
						|
.B \fI\%Mjma\fP
 | 
						|
Mjma is computed on displacement data using body waves of period < 30s.
 | 
						|
.TP
 | 
						|
.B \fI\%ML\fP
 | 
						|
Local (Richter) magnitude calculated on the horizontal components using a
 | 
						|
correction term to fit with the standard ML (Richter [\fI\%57\fP]).
 | 
						|
.TP
 | 
						|
.B \fI\%MLc\fP
 | 
						|
Local custom magnitude calculated on the horizontal components according to
 | 
						|
Hessian Earthquake Service and Stange [\fI\%62\fP]
 | 
						|
.TP
 | 
						|
.B \fI\%MLh\fP
 | 
						|
Local magnitude calculated on the horizontal components according to SED
 | 
						|
specifications.
 | 
						|
.TP
 | 
						|
.B \fI\%MLv\fP
 | 
						|
Local magnitude calculated on the vertical component using a correction term
 | 
						|
to fit with the standard ML.
 | 
						|
.TP
 | 
						|
.B AMN for \fI\%MN\fP
 | 
						|
Nuttli magnitude for Canada and other Cratonic regions (Nuttli [\fI\%53\fP]).
 | 
						|
.UNINDENT
 | 
						|
.SS Teleseismic distances
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \fI\%mb\fP
 | 
						|
Narrow band body wave magnitude measured on a WWSSN\-SP filtered trace
 | 
						|
.TP
 | 
						|
.B \fI\%mBc\fP
 | 
						|
Cumulative body wave magnitude
 | 
						|
.TP
 | 
						|
.B \fI\%mB\fP
 | 
						|
Broad band body wave magnitude after Bormann and Saul [\fI\%38\fP]
 | 
						|
.TP
 | 
						|
.B \fI\%Mwp\fP
 | 
						|
The body wave magnitude of Tsuboi \fIet al.\fP [\fI\%63\fP]
 | 
						|
.TP
 | 
						|
.B \fI\%Ms_20\fP
 | 
						|
Surface\-wave magnitude at 20 s period
 | 
						|
.TP
 | 
						|
.B \fI\%Ms(BB)\fP
 | 
						|
Broad band surface\-wave magnitude
 | 
						|
.UNINDENT
 | 
						|
.SH ACCELERATION INPUT DATA
 | 
						|
.sp
 | 
						|
For amplitudes to be computed, the input waveforms are usually given in velocity.
 | 
						|
Acceleration data, e.g. from strong\-motion instruments must therefore be transformed
 | 
						|
to velocity. The transformation is enabled by activating the response correction.
 | 
						|
Activate the correction in the global bindings for all
 | 
						|
types or in a new Amplitude type profile for specific types.
 | 
						|
.sp
 | 
						|
Example global binding parameters for computing MLv amplitudes from accleration
 | 
						|
data. Here, the frequency range is limited to 0.5 \- 20 Hz:
 | 
						|
.INDENT 0.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
amplitudes.MLv.enableResponses = true
 | 
						|
amplitudes.MLv.resp.taper = 5
 | 
						|
amplitudes.MLv.resp.minFreq = 0.5
 | 
						|
amplitudes.MLv.resp.maxFreq = 20
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SH RE-PROCESSING
 | 
						|
.sp
 | 
						|
\fIscamp\fP can be used to reprocess and to update amplitudes, e.g. when inventory paramters
 | 
						|
had to be changed retrospectively. Updating ampitudes requires waveform access.
 | 
						|
The update can be performed
 | 
						|
.INDENT 0.0
 | 
						|
.IP 1. 3
 | 
						|
In \fBoffline processing\fP based on XML files (\fB\-\-ep\fP). \fB\-\-reprocess\fP
 | 
						|
will replace exisiting amplitudes. Updated values can be dispatched to the messing by
 | 
						|
\fI\%scdispatch\fP making them available for further processing, e.g. by \fI\%scmag\fP\&.
 | 
						|
.sp
 | 
						|
\fBExample:\fP
 | 
						|
.INDENT 3.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
$ scamp \-\-ep evtID.xml \-d [type]://[host]/[database] \-\-reprocess > evtID_update.xml
 | 
						|
$ scdispatch \-O merge \-H [host] \-i evtID_update.xml
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.IP 2. 3
 | 
						|
\fBWith messaging\fP by setting \fBstart\-time\fP or \fBend\-time\fP\&.
 | 
						|
All parameters are read from the database. \fB\-\-commit\fP will
 | 
						|
send the updated parameters to the messing system making them available for
 | 
						|
further processing, e.g. by \fI\%scmag\fP\&. Otherwise, XML output is generated.
 | 
						|
.sp
 | 
						|
\fBExample:\fP
 | 
						|
.INDENT 3.0
 | 
						|
.INDENT 3.5
 | 
						|
.sp
 | 
						|
.nf
 | 
						|
.ft C
 | 
						|
$ scamp \-u testuser \-H [host] \-\-commit \e
 | 
						|
        \-\-start\-time \(aq2016\-10\-15 00:00:00\(aq \-\-end\-time \(aq2016\-10\-16 19:20:00\(aq
 | 
						|
.ft P
 | 
						|
.fi
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.UNINDENT
 | 
						|
.SH MODULE CONFIGURATION
 | 
						|
.nf
 | 
						|
\fBetc/defaults/global.cfg\fP
 | 
						|
\fBetc/defaults/scamp.cfg\fP
 | 
						|
\fBetc/global.cfg\fP
 | 
						|
\fBetc/scamp.cfg\fP
 | 
						|
\fB~/.seiscomp/global.cfg\fP
 | 
						|
\fB~/.seiscomp/scamp.cfg\fP
 | 
						|
.fi
 | 
						|
.sp
 | 
						|
.sp
 | 
						|
scamp inherits \fI\%global options\fP\&.
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B amplitudes
 | 
						|
Default: \fBMLv, mb, mB, Mwp\fP
 | 
						|
.sp
 | 
						|
Type: \fIlist:string\fP
 | 
						|
.sp
 | 
						|
Definition of magnitude types for which amplitudes are to be calculated.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B amptool.minimumPickWeight
 | 
						|
Default: \fB0.5\fP
 | 
						|
.sp
 | 
						|
Type: \fIdouble\fP
 | 
						|
.sp
 | 
						|
The minimum arrival weight within an origin to compute amplitudes for the associated pick.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B amptool.streamFromBindings
 | 
						|
Default: \fBfalse\fP
 | 
						|
.sp
 | 
						|
Type: \fIboolean\fP
 | 
						|
.sp
 | 
						|
If enabled then global bindings will be used to replace
 | 
						|
location code and channel code of a pick with the configured
 | 
						|
values of detecLocid and detecStream for amplitude computation.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B amptool.initialAcquisitionTimeout
 | 
						|
Default: \fB30\fP
 | 
						|
.sp
 | 
						|
Type: \fIdouble\fP
 | 
						|
.sp
 | 
						|
Unit: \fIs\fP
 | 
						|
.sp
 | 
						|
Timeout in seconds of the first data packet of waveform data acquisition.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B amptool.runningAcquisitionTimeout
 | 
						|
Default: \fB2\fP
 | 
						|
.sp
 | 
						|
Type: \fIdouble\fP
 | 
						|
.sp
 | 
						|
Unit: \fIs\fP
 | 
						|
.sp
 | 
						|
Timeout in seconds of any subsequent data packet of waveform data acquisition.
 | 
						|
.UNINDENT
 | 
						|
.SH COMMAND-LINE OPTIONS
 | 
						|
.SS Generic
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-h, \-\-help
 | 
						|
Show help message.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-V, \-\-version
 | 
						|
Show version information.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-file arg
 | 
						|
Use alternative configuration file. When this option is
 | 
						|
used the loading of all stages is disabled. Only the
 | 
						|
given configuration file is parsed and used. To use
 | 
						|
another name for the configuration create a symbolic
 | 
						|
link of the application or copy it. Example:
 | 
						|
scautopick \-> scautopick2.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-plugins arg
 | 
						|
Load given plugins.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-D, \-\-daemon
 | 
						|
Run as daemon. This means the application will fork itself
 | 
						|
and doesn\(aqt need to be started with &.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-auto\-shutdown arg
 | 
						|
Enable/disable self\-shutdown because a master module shutdown.
 | 
						|
This only works when messaging is enabled and the master
 | 
						|
module sends a shutdown message (enabled with \-\-start\-stop\-msg
 | 
						|
for the master module).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-module arg
 | 
						|
Set the name of the master\-module used for auto\-shutdown.
 | 
						|
This is the application name of the module actually
 | 
						|
started. If symlinks are used, then it is the name of
 | 
						|
the symlinked application.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-shutdown\-master\-username arg
 | 
						|
Set the name of the master\-username of the messaging
 | 
						|
used for auto\-shutdown. If \(dqshutdown\-master\-module\(dq is
 | 
						|
given as well, this parameter is ignored.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-x, \-\-expiry time
 | 
						|
Time span in hours after which objects expire.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-O, \-\-origin\-id publicID
 | 
						|
OriginID to calculate amplitudes for and exit.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-dump\-records
 | 
						|
Dumps the filtered traces to ASCII when using \-O.
 | 
						|
.UNINDENT
 | 
						|
.SS Verbosity
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-verbosity arg
 | 
						|
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info,
 | 
						|
4:debug.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-v, \-\-v
 | 
						|
Increase verbosity level (may be repeated, eg. \-vv).
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-q, \-\-quiet
 | 
						|
Quiet mode: no logging output.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-component arg
 | 
						|
Limit the logging to a certain component. This option can
 | 
						|
be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-s, \-\-syslog
 | 
						|
Use syslog logging backend. The output usually goes to
 | 
						|
/var/lib/messages.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-l, \-\-lockfile arg
 | 
						|
Path to lock file.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-console arg
 | 
						|
Send log output to stdout.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-debug
 | 
						|
Execute in debug mode.
 | 
						|
Equivalent to \-\-verbosity=4 \-\-console=1 .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-log\-file arg
 | 
						|
Use alternative log file.
 | 
						|
.UNINDENT
 | 
						|
.SS Messaging
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-u, \-\-user arg
 | 
						|
Overrides configuration parameter \fI\%connection.username\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-H, \-\-host arg
 | 
						|
Overrides configuration parameter \fI\%connection.server\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-t, \-\-timeout arg
 | 
						|
Overrides configuration parameter \fI\%connection.timeout\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-g, \-\-primary\-group arg
 | 
						|
Overrides configuration parameter \fI\%connection.primaryGroup\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-S, \-\-subscribe\-group arg
 | 
						|
A group to subscribe to.
 | 
						|
This option can be given more than once.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-content\-type arg
 | 
						|
Overrides configuration parameter \fI\%connection.contentType\fP\&.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-start\-stop\-msg arg
 | 
						|
Set sending of a start and a stop message.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-test
 | 
						|
Test mode where no messages are sent.
 | 
						|
.UNINDENT
 | 
						|
.SS Database
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-db\-driver\-list
 | 
						|
List all supported database drivers.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-d, \-\-database arg
 | 
						|
The database connection string, format:
 | 
						|
\fI\%service://user:pwd@host/database\fP\&.
 | 
						|
\(dqservice\(dq is the name of the database driver which
 | 
						|
can be queried with \(dq\-\-db\-driver\-list\(dq.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-config\-module arg
 | 
						|
The config module to use.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-inventory\-db arg
 | 
						|
Load the inventory from the given database or file, format:
 | 
						|
[\fI\%service://]location\fP .
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-db\-disable
 | 
						|
Do not use the database at all
 | 
						|
.UNINDENT
 | 
						|
.SS Records
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-record\-driver\-list
 | 
						|
List all supported record stream drivers.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-I, \-\-record\-url arg
 | 
						|
The recordstream source URL, format:
 | 
						|
[\fI\%service://\fP]location[#type].
 | 
						|
\(dqservice\(dq is the name of the recordstream driver
 | 
						|
which can be queried with \(dq\-\-record\-driver\-list\(dq.
 | 
						|
If \(dqservice\(dq is not given, \(dq\fI\%file://\fP\(dq is
 | 
						|
used.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-record\-file arg
 | 
						|
Specify a file as record source.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-record\-type arg
 | 
						|
Specify a type for the records being read.
 | 
						|
.UNINDENT
 | 
						|
.SS Input
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-ep file
 | 
						|
Defines an event parameters XML file to be read and processed. This
 | 
						|
implies offline mode and only processes all origins contained
 | 
						|
in that file. It computes amplitudes for all picks associated
 | 
						|
with an origin and outputs an XML file that additionally
 | 
						|
contains the amplitudes.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-p, \-\-picks
 | 
						|
Force measuring amplitudes for picks only. Origins are
 | 
						|
ignored and time windows are independent of distance. Works
 | 
						|
only in combination with \-\-ep.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-reprocess
 | 
						|
Reprocess and update existing amplitudes. Manual amplitudes
 | 
						|
will be skipped. Works only in combination with \-\-ep.
 | 
						|
This option can be used, e.g., for reprocessing amplitudes
 | 
						|
with new inventory information. Waveform access is required.
 | 
						|
.UNINDENT
 | 
						|
.SS Reprocess
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-force
 | 
						|
Forces reprocessing of all amplitudes, even manual ones.
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-start\-time time
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-end\-time time
 | 
						|
.UNINDENT
 | 
						|
.INDENT 0.0
 | 
						|
.TP
 | 
						|
.B \-\-commit
 | 
						|
Send amplitude updates to the messaging otherwise an XML
 | 
						|
document will be output.
 | 
						|
.UNINDENT
 | 
						|
.SH AUTHOR
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.SH COPYRIGHT
 | 
						|
gempa GmbH, GFZ Potsdam
 | 
						|
.\" Generated by docutils manpage writer.
 | 
						|
.
 |