<?xml version="1.0" encoding="UTF-8"?>
 | 
						|
<seiscomp>
 | 
						|
        <plugin name="Md">
 | 
						|
                <extends>global</extends>
 | 
						|
                <description>
 | 
						|
                Duration magnitude plugin
 | 
						|
                </description>
 | 
						|
	</plugin>
 | 
						|
	<binding name="Md" module="global">
 | 
						|
		<description>
 | 
						|
		Duration magnitude plugin
 | 
						|
		</description>
 | 
						|
		<configuration>
 | 
						|
			<group name="magnitudes">
 | 
						|
				<group name="md">
 | 
						|
					<parameter name="seismo" type="int" default="9">
 | 
						|
						<description>
 | 
						|
						Default filter type to use before processing and after deconvolution. It's possible to set :
 | 
						|
						1 for a Wood-Anderson seismometer
 | 
						|
						2 for a 5sec generic Seismometer
 | 
						|
						3 for a WWSSN LP seismometer
 | 
						|
						4 for a WSSN SP seismometer
 | 
						|
						5 for a Generic Seismometer
 | 
						|
						6 for a Butterworth Low pass filter
 | 
						|
						7 for a Butterworth High pass filter
 | 
						|
						8 for a Butterworth Band pass filter
 | 
						|
						9 for a 1Hz eigen-frequency L4C seismometer
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="taper" type="double" default="5" unit="s">
 | 
						|
						<description>
 | 
						|
						taper applied to the signal
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="signal_length"  type="double" default="150" unit="s">
 | 
						|
						<description>
 | 
						|
						signal length used to compute the duration magnitude
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="butterworth" type="string" default=""3,1.5"">
 | 
						|
						<description>
 | 
						|
						Butterworth filter parameter applied to the signal
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="depthmax" type="double" default="200" unit="km">
 | 
						|
						<description>
 | 
						|
						Maximum depth at which duration magnitude is valid
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="deltamax" type="double" default="400" unit="km">
 | 
						|
						<description>
 | 
						|
						Maximum distance between earthquake and station at which duration magnitude is valid
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="snrmin" type="double" default="1.2">
 | 
						|
						<description>
 | 
						|
						Signal to noise ratio below which the coda is reached
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="mdmax" type="double" default="5.0">
 | 
						|
						<description>
 | 
						|
						Maximum expected duration magnitude value
 | 
						|
						This is used to find how much data should be loaded for a given station by reversing the formula
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="fma" type="double" default="-0.87">
 | 
						|
						<description>
 | 
						|
						FMA regional coefficient
 | 
						|
						See Hypo2000 manual
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="fmb" type="double" default="2.0">
 | 
						|
						<description>
 | 
						|
						FMB regional coefficient
 | 
						|
						See Hypo2000 manual
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="fmd" type="double" default="0.0035">
 | 
						|
						<description>
 | 
						|
						FMD regional coefficient
 | 
						|
						See Hypo2000 manual
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="fmf" type="double" default="0.0">
 | 
						|
						<description>
 | 
						|
						FMF regional coefficient
 | 
						|
						See Hypo2000 manual
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="fmz" type="double" default="0.0">
 | 
						|
						<description>
 | 
						|
						FMZ regional coefficient
 | 
						|
						See Hypo2000 manual
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="linearcorrection" type="double" default="1.0">
 | 
						|
						<description>
 | 
						|
						Linear correction
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="offset" type="double" default="0.0">
 | 
						|
						<description>
 | 
						|
						Offset
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
					<parameter name="stacor" type="double" default="0.0">
 | 
						|
						<description>
 | 
						|
						Station correction
 | 
						|
						</description>
 | 
						|
					</parameter>
 | 
						|
				</group>
 | 
						|
			</group>
 | 
						|
		</configuration>
 | 
						|
	</binding>
 | 
						|
</seiscomp>
 |