.. _scanloc-spicker:

Advanced S-Phase Detector
=========================

The :ref:`scanloc` package provides the enhanced S-phase detectors,
S-AIC and S-AIC-V, as well as the :ref:`debugger<scanloc-spick-debugger>`.


Overview
--------

The *scanloc* package includes two S phase pickers: S-AIC and S-AIC-V, enhancing the
performance of the picker with respect to the OpenSource S-L2. Both picker
apply an AIC algorithm in order to detect S phases after a P pick was maked.
Therefore S phases are only detected after a P detection.
Using the S-AIC, S picks are determined on the vectorial sum of the horizontal
componentes (L2 trace).
The S-AIC-V works like the S-AIC but it picks S phases on the vertical component.

The method which was applied to make the pick can be read

* In the method column of the arrival table in the Location tab of :cite:t:`scolv`,
* In the picker window from the letter within brackets following a phase type,
* In the picker window from the hint which appears when hovering over a
  pick.

.. _scanloc-fig-picker-method:

.. figure:: ./media/scolv-picker-method.png
   :align: center
   :width: 10cm

   Read the method applied to make a pick in the arrival table of scolv or in
   the picker window.

The performance of the pickers have been tested by comparison of automatic
with manual picks (see the :ref:`Figure showing the comparison<scanloc-fig-picker-comparison>`).

.. _scanloc-fig-picker-comparison:

.. figure:: ../apps/media/hist_comp_vgt.png
   :align: center
   :width: 10cm

   Performance comparison showing the differences in pick time from manual picks
   and the optimally tuned pickers S-L2, S-AIC and S-AIC-V for local earthquakes
   in West-Bohemia/Vogtland. The area is typical of local earthquake monitored at
   short epicentral distances of a few tens of kilometers. The distribution of
   the differences in the automatic pick times with respect to the manual ones
   shows the increased performance using the S-AIC.


Picker configuration
--------------------

1. **Global module parameters:** Add the plugin *saic* to the configuration of
   :program:`scautopick` or the global
   module configuration for making use of the S-AIC or the S-AIC-V:

   .. code-block:: sh

      plugins = ${plugins},saic

#. **Module parameters:** Activate one of the S-phase ickers (S-L2, S-AIC, S-AIC-V)
   by changing the name of the S picker in the module
   configuration of :program:`scautopick`. Deactivating *killPendingSPickers* will allow
   to pick S phases even if more P phases were detected before:

   .. code-block:: sh

      spicker = "S-AIC"
      killPendingSPickers = false

#. **Bindings parameters:** Configure the S-picker parameters under *spicker* in
   global section of the bindings of :program:`scautopick` e.g. for
   *S-AIC* in local earthquake monitoring. For tuning the values based on actual
   data you may use the :ref:`graphical debugger <scanloc-spick-debugger>`:

   .. code-block:: sh

      detecFilter = "RMHP(10)>>ITAPER(30)>>BW(4,4,20)>>STALTA(0.2,20)"
      timeCorr = 0

      spicker.AIC.noiseBegin = -10
      spicker.AIC.signalBegin = 0.5
      spicker.AIC.filter = "ITAPER(4)>>BW_HP(4,3)"
      spicker.AIC.detecFilter = ""
      spicker.AIC.step = 0.5
      spicker.AIC.minSNR = 5
      spicker.AIC.minCnt = 5

   The AIC parameters *spicker.AIC.* are used for *S-AIC* and for *S-AIC-V*.
   The parameters of the S-phase pickers can be configured in the global section of the
   bindings profile of :program:`scautopick`. The meaning of some parameters are shared
   between the S-phase pickers:

   .. _scanloc-table-parameter:

   .. csv-table::
      :header: "Parameter", "Picker type", "Description"
      :widths: 15,25,60

      ":confval:`noiseBegin`","S-AIC, S-AIC-V, S-L2","Data window added before the p pick on order to compensate
      for effects due to the data processing, filtering and to compute the SNR."
      ":confval:`signalBegin`","S-AIC, S-AIC-V, S-L2","Start of the data processing relative to the reference P pick."
      ":confval:`signalEnd`","S-AIC, S-AIC-V, S-L2","End of the data processing relative to the reference P pick."
      ":confval:`filter`","S-AIC, S-L2","Filter applied before forming the L2 trace."
      ":confval:`detectFilter`","S-AIC, S-AIC-V, S-L2","Filter applied on the L2 trace before AIC analysis."
      ":confval:`step`","S-AIC, S-AIC-V","Step size in which the time windows are enlarged."
      ":confval:`minSNR`","S-AIC, S-AIC-V, S-L2","Minimum SNR in order to accept a pick."
      ":confval:`minCnt`","S-AIC, S-AIC-V","Minimum number the AIC minimum must be found for subsequent time windows."
      ":confval:`uncertainty`","S-AIC, S-AIC-V","Pick uncertainty. Unused by the picker but part of the output pick element."


.. _scanloc-spick-debugger:

Picker tuning: Debugger
-----------------------

The :ref:`debugger GUI<scanloc-fig-debugger>` allows the graphics-assisted tuning
of the S pickers, S-L2, S-AIC, S-AIC-V. In order to make use of the S picker
debugging GUI:

#. **Global module parameters:** Add the plugin *spickdbg* to the global
   configuration of :cite:t:`scolv` (:file:`scolv.cfg`)

   .. code-block:: params

      plugins = ${plugins}, spickdbg

#. **Global bindings:** Configure the initial parameters in the global bindings
   of the considered stream. You may adopt parameters from the ones used by the
   *spicker* for a good inital guess.

The debugger GUI can be started from the picker window of :program:`scolv`.
If there is an existing P pick, the debugger window can be opened with a
right click on the P pick. In the dropdown menu the S picker type can be chosen.

.. _scanloc-fig-picker-debugger-menu:

.. figure:: ./media/scolv-picker-debugger-open.png
   :align: center
   :width: 10cm

   Selection of S-picker debugger by right-clicking on a P phase.

A new pop-up window opens where the P pick (red line) and the newly determined S
pick (light blue line) are shown and the parameters can be tested.

.. _scanloc-fig-debugger:

.. figure:: ./media/s-picker-debugger.png
   :align: center
   :width: 10cm

   S-picker debugger example showing the filtered horizontal traces, the
   computed L2 trace and the resulting S pick (light blue line).

The :ref:`example above <scanloc-fig-debugger>` shows the debugger GUI for a local
earthquake:

* **Top traces:** original filtered data.
* **Bottom trace:** Resulting trace e.g. L2.
* **First red line:** the time of the referenced pick. A pick pick should be selected.
* **Additional phase picks** are shown on top of the data.
* **Light blue line:** the S pick which would be made based on the selected
  parameters. The number next to 'AIC' indicates the SNR.
* **Lower section:** Parameters which can be adjusted.

The initial parameters are read from the global binding configuration from the
selected stream. Change the parameters to find the optimum
values. Click on the *Update* button to apply them in the GUI.
In order to make use of the tested parameters their values must be configured in
the bindings parameter of :program:`scautopick` or the respective alias.

.. _scanloc-debugger-parameters:

.. csv-table::
   :header: "Parameter", "Description"
   :widths: 15,85

   "N","Start of the noise window"
   "S0","Start of the AIC window"
   "S1","End of the AIC window"
   "AIC0","Start of the data processing relative to the reference P pick."
   "AIC","S pick based on the current parameters with number indicating the SNR."
   "AIC1","End of the data processing when meeting MinSNR and MinCnt."
   "Pick","Pick time at AIC."